| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 56,080 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 774 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 610). Agency page | Dec 31, 2030 in 1504 days | Next due 2030 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-05 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 23, 2024 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) #00432 | DOB VIOLATION - ACTIVE |
| Jun 20, 2021 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2020 #10538 | DOB VIOLATION - ACTIVE |
| May 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #03707 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Jun 23, 2024 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Jun 20, 2021 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| May 2, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 13, 2015 | B | Apt 1B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 20, 2015 |
| Feb 13, 2015 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 20, 2015 |
| Sep 23, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZER SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON RING FOR COULD WATER SUPPLY PIPE UNDER WASHBASIN IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CEILING LIGHT FIXTURE IN THE FOYER LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | A | Apt 6F · § 27-2041 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR ... IN THE ENTRANCE LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Dec 27, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CEILING LIGHT FIXTURE IN THE PRIVATE HALLWAY LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 23, 2009 | A | Apt 6F · § 27-2005 ADM CODE REFIT WINDOW AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Dec 27, 2009 |
| Sep 23, 2009 | B | Apt 6F · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT SINK IN THE KITCHEN LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST | Oct 28, 2009 |
| Sep 9, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 6F, 6th STORY | Oct 14, 2009 |
| Sep 9, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6F, 6th STORY | Oct 14, 2009 |
| Sep 9, 2009 | B | Apt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6F, 6th STORY | Oct 14, 2009 |
| Sep 9, 2009 | B | Apt 6F · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY | Oct 14, 2009 |
| Sep 9, 2009 | B | Apt 6F · § 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS .. IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY | Oct 14, 2009 |
| Sep 9, 2009 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 6F, 6th STORY | Oct 14, 2009 |