Brooklyn · Block 1539 · Lot 63 · 11233

85 Somers Street

3 floors · 3 apartments · 3,213 sq ft · built 1910 · class C0 · owner of record: Bkmg S-85 Llc

15open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 64 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual

Open violations

ECB / OATH (5)
IssuedViolationHearingBalance
Jul 13, 2021Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT FRONT,RETAINING WALL LEANING OUTWARD & HAS CRACKS. AT EXP#1 ABOVE THE FRONT ENTRY DOOR BIG CRACK OBSERVED. PHOTO TAKEN. REMEDY: REPAIR &/OR REPLACE.
#35495838Z
Nov 24, 2021
DEFAULT
$0
Jun 1, 2021Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.NOTED:ATOI,OBSERVED@EXP1(FRONT) ROOF LEVEL@MIDDLE&RIGHT OF FACADE:HAVE CRACKS,MISSING MORTAR&SECS LEANING&BULGING.ALSO,SIDEWALK TO THE MASONRY STEPS FACING PUBLI
#35557869M
Oct 13, 2021
DEFAULT
$0
Mar 30, 2021Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT EXP#1;THEFACADE HAS LARGE CRACKS & THE TOP SECTIONS AT THE RIGHT CORNER LEANING. ALSO,THE SIDEWALL OF STEPS HAVE RUNNING STEP CRACKS,DISLODGED BRICKS
#35546523L
Aug 11, 2021
DEFAULT
$0
Oct 27, 2020Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED AT EXPOSURE 1 SIDEWLAK OF THE MASONRY STEPS FACING THE SIDEWALK HAS RUNNING STEP CRACKS HAS AREAS THAT SHIFTED ALSO AT THE FACADE HAS RUNNING STEP CR
#35490968Y
Mar 10, 2021
DEFAULT
$0
Jun 19, 2020Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES AT TH ETIME OF INSPECTION OBSERVED RETAININGW ALL AT EXPOSURE #1 OF SUBJECT PREMISES DISPLACED AND TILTED TOWARDS SIDEWALK THE WALL IS APPROX 11 FEET TALL A
#35477775L
Oct 21, 2020
DEFAULT
$0
DOB (5)
IssuedViolationStatus
Mar 14, 2024CONSTRUCTION
STRUCTURE RENDERED NON COMPLIANT. AT TIME OF INSPECTION OBSERVED EXTENSIVE FIRE,WATER AND SMOKE DAMAGE THROUGHOUT. ROOF IS OPEN,WINDOWS ARE OUT.
#24-00775
DOB VIOLATION - ACTIVE
Sep 1, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00268
DOB VIOLATION - ACTIVE
Jun 23, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00309
DOB VIOLATION - ACTIVE
Jan 20, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00284
DOB VIOLATION - ACTIVE
Sep 16, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00313
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Apr 15, 2024Structurally Compromised Buildings FTF-SC-INITL
Active
Sep 1, 2021AEUHAZ FTC-AEU-HAZ
Active
Jun 23, 2021AEUHAZ FTC-AEU-HAZ
Active
Jan 20, 2021AEUHAZ FTC-AEU-HAZ
Active
Sep 16, 2020AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 9:22 AM ET. BBL 3015390063.

Look up another building