4 floors · 47,426 sq ft · built 1931 · class O5 · owner of record: 839 Broadway Tic F Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 70 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 47,426 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 9, 2018 | Construction CLASS - 1 GUARD RAILS-FAILURE TO MAINTAIN AT TIME OF INSPECTION OBSERVED GUARD RAILS.NOT CONSTRUCTED PER CODE:USE OF 2X3 AND NOT AT CORRECT HEIGHTS.PROVVIDE 2X4 GUARD RAIL SYSTEMS.CONTACT BEST FOR RE-INSPECTION. #35342706J | Dec 5, 2018 IN VIOLATION | $2,500 |
| Jul 9, 2018 | Construction CLASS - 1 BC3301.5.SIDEWALK SHED.AT TIME OF INSPECTION OBSERVED SIDEWALK SHED WITH MISSING VERTICAL THAT HAS BEEN REMOVED.BOLTS TO SECURE MEMBERS UNPROTECTED WHICH COULD INJURE PUBLIC.STABILITY OF SIDEWALK SHED QUESTIONE #35342700Z | Nov 28, 2018 IN VIOLATION | $2,400 |
| Jul 9, 2018 | Construction CLASS - 1 BC3301.7.DESIGN DRAWING FOR PLATFORMS.AT TIME OF INSPECTION OBSERVED PLATFORMS OVER STAIRS AT 2ND&3RD FLOOR CONSISTING OF PLANKS & PLYWOOD & BEING SUPPORTED BY 2X4,WHEN I REQUESTED DESIGN DRAWING FOR MAKESHIFT #35327147R | Mar 6, 2019 IN VIOLATION | $625 |
| Jul 9, 2018 | Construction CLASS - 1 BC3309.10.ROOF PROTECTION-INADEQUATE AT TIME OF INSPECTION OBSERVED INADEQUATE ROOF PROTECTION.OBSERVED WOOD PLANKS NOT LAID TIGHT AS REQUIRED ALSO OBSERVED STOP ALL WORK WITHIN 10-0 OF EXPOSURE#4.PROVIDE ROOF #35342705H | Dec 5, 2018 IN VIOLATION | $2,500 |
| Jul 9, 2018 | Construction CLASS - 1 BC3314.8.FAILURE TO MAINTAIN SCAFFOLD NETTING.AT TIME OF INSPECTION OBSERVED SIDEWALK SCAFFOLDING ERECTED WITH REQUIRED NETS MISSING,LOOSE AND NOT MAINTAINED PER CODE.AT EXP 1,2,DEBRIS NETTING NOT SECURED AND P #35327148Z | Mar 11, 2019 IN VIOLATION | $2,500 |
| Jul 9, 2018 | Construction CLASS - 1 BC3314.2.SCAFFOLD BASE PLATES.AT TIME OF INSPECTION OBSERVED 5 SETS OF SCAFFOLDS ON 1ST FLOOR.NONE OF THEM HAS BASE PLATES/LEVELERS WHICH CREATES A CONDITION WHERE THEY COULD FALL OVER.ALL SCAFFOLDS OBSERVED WH #35327149K | Nov 28, 2018 IN VIOLATION | $2,500 |
| Jul 9, 2018 | Construction CLASS - 1 BC3303.11.TREE PROTECTION.AT TIME OF INSPECTION OBSERVED NO TREE PROTECTION PROVIDED TO TWO(2) TREES LOCATED ON SIDEWALK &IN PATH OF SIDEWALK SHED.PROVIDE TREE PROTECTION PER CODE #35342707L | Dec 5, 2018 IN VIOLATION | $625 |
| Jul 9, 2018 | Construction CLASS - 1 CONTRARY TO MANUFACTURERS SPECIFICATIONS-ELECTRICAL AT TIME OF INSPECTION OBSERVED FOUR(4) ELECTRICAL CORD WITH(40)GROUND WIRE IN USE AND OBSERVED EXTENSION CORD PLUGGED IN 3 SOCKETS AND ALSO WITH NO GROUND WIR #35342701K | Dec 5, 2018 IN VIOLATION | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 6:36 AM ET. BBL 3031340005.