| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 321,452 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1325). Agency page | Dec 31, 2035 in 3352 days | Next due 2035 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | On file | Cycle 10 filing on record: SWARMP (2026-01-08) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 18, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES ON DIFFERENT FLOORS. UPON REQUIRE SITE SAFETY TRAINING CARDS TO A GROUP OF WORKERS, THEY SAID THEY WILL GET THE CARDS BUT NEVER CAME BACK TO PROVIDE #39558082Z | Apr 9, 2027 PENDING | $2,500 |
| Aug 18, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED SIDEWALK SHED AT EXPOSURE 1, 2 AND 4. NO INFORMATION PANEL POSTED ON ANY OF THIS EXPOSURE CONTRARY TO BC 3301.9. UNSAFE CONDITION DUE TO FIRST RESPONDENTS WILL NOT BE ABLE TO LOCA #39558081R | Oct 22, 2026 IN VIOLATION | $1,250 |
| Aug 18, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED SEVERAL LOCATION WITH LARGE OPENINGS ON CONCRETE SLABS. OBSERVED INADEQUATE GUARDRAIL SYSTEM, MISSING TOE BOARDS OR NOT IN CONTACT WITH DECK. ALSO OBSERVED AREAS WHERE RAILINGS NO #39558080P | Oct 22, 2026 IN VIOLATION | $2,500 |
| Aug 18, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION SITE. UPON REVIEWING SITE SAFETY PLAN NOTICE SOME AREAS DOES NOT CONFORM. AT EXP. 3 ON 2ND FLOOR OBSERVED A TERRACE AND ON ADJ. PROPERTY OBSERVED SUSPENDED SCA #39558077Y | Oct 22, 2026 IN VIOLATION | $625 |
| Aug 18, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION ON ACTIVE SITE CONSTRUCTION SUPERINTENDENT COULD NOT PROVIDED THE FOLLOWING DOCUMENTS. SIDEWALK SHED AND SUPPORTED SCAFFOLD DRAWINGS, INSTALLATION LETTERS AND DAILY INSPECTIONS FOR BOTH. N #39558076M | Oct 22, 2026 IN VIOLATION | $1,250 |
| Aug 18, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES AS PER DOB RECORDS JOB APPLICATION M01277486 REQUIRES SSM TO BE ON SITE. UPON INQUIRE ABOUT SSM, CONSTRUCTION SUPER SAID HE WAS NOT ON SITE, NO RECO #39558074Z | Apr 9, 2027 PENDING | $10,000 |
| Jul 20, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION, ACTIVE DEMOLITION AND HOUSEKEEPING WERE OBSERVED ON THE 12TH AND GROUND FLOORS OF THE 21-STORY BUILDING. UPON REQUEST, THE REQUIRED SITE LOGBOOKS WERE NOT AVAILABLE FOR INSPECTION, PR #39556827P | Sep 24, 2026 DEFAULT | $1,280 |
| Issued | Violation | Status |
|---|---|---|
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01162 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 25, 2026 | DOB Safety | AEUHAZ: | Closed |
| Aug 18, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES. ON ENTIRE SITE OBSERVED INADEQUATE FIRE EXTINGUISHERS WITH EXPIRED INSPECTION TAGS, STORE ON FLOOR, NO SIGNAGE. OBSERVED ON SEVERAL FLOOR EVIDENCE | Closed |
| Aug 18, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES ON DIFFERENT FLOORS. UPON REQUIRE SITE SAFETY TRAINING CARDS TO A GROUP OF WORKERS, THEY SAID THEY WILL GET THE CARDS BUT NEVER CAME BACK TO PROVIDE | Open |
| Aug 18, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED SIDEWALK SHED AT EXPOSURE 1, 2 AND 4. NO INFORMATION PANEL POSTED ON ANY OF THIS EXPOSURE CONTRARY TO BC 3301.9. UNSAFE CONDITION DUE TO FIRST RESPONDENTS WILL NOT BE ABLE TO LOCA | Open |
| Aug 18, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED SEVERAL LOCATION WITH LARGE OPENINGS ON CONCRETE SLABS. OBSERVED INADEQUATE GUARDRAIL SYSTEM, MISSING TOE BOARDS OR NOT IN CONTACT WITH DECK. ALSO OBSERVED AREAS WHERE RAILINGS NO | Open |
| Aug 18, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION SITE. UPON REVIEWING SITE SAFETY PLAN NOTICE SOME AREAS DOES NOT CONFORM. AT EXP. 3 ON 2ND FLOOR OBSERVED A TERRACE AND ON ADJ. PROPERTY OBSERVED SUSPENDED SCA | Open |
| Aug 18, 2026 | ECB | Construction: AT TIME OF INSPECTION ON ACTIVE SITE CONSTRUCTION SUPERINTENDENT COULD NOT PROVIDED THE FOLLOWING DOCUMENTS. SIDEWALK SHED AND SUPPORTED SCAFFOLD DRAWINGS, INSTALLATION LETTERS AND DAILY INSPECTIONS FOR BOTH. N | Open |
| Aug 18, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES AS PER DOB RECORDS JOB APPLICATION M01277486 REQUIRES SSM TO BE ON SITE. UPON INQUIRE ABOUT SSM, CONSTRUCTION SUPER SAID HE WAS NOT ON SITE, NO RECO | Open |
| Aug 18, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED ON GOING HOT WORK ON ELEVATOR SHAFT. SPARKS WHERE FALLING ON FLAMMABLE MATERIALS UNDER HOT WORK INCLUDING ELEVATOR. OBSERVED ONLY ONE PERSON NEAR HOT WORK OTHER THAN WORKER PRODUC | Closed |
| Jul 20, 2026 | ECB | Construction: AT THE TIME OF INSPECTION, ACTIVE DEMOLITION AND HOUSEKEEPING WERE OBSERVED ON THE 12TH AND GROUND FLOORS OF THE 21-STORY BUILDING. UPON REQUEST, THE REQUIRED SITE LOGBOOKS WERE NOT AVAILABLE FOR INSPECTION, PR | Open |