3 floors · 23,838 sq ft · built 1925 · class O5 · owner of record: La Gree Baptist Church, Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 789 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 19, 2021 | Construction CLASS - 1 AT TIME OF INSPECTION, A KNUCKLE BOOM WAS ON SITE ENGAGED IN STEEL ERECTION OPERATIONS. THE KNUCKLE BOOM WAS HOLDING IN STEEL IN PLACE WHILE IT WAS BEING INSTALLED. NO CERTIFICATE OF APPROVAL WAS PROVIDED FOR T #39044628N | Sep 3, 2021 DEFAULT | $12,500 |
| Jul 19, 2021 | Cranes and Derricks CLASS - 2 AT TIME OF INSPECTION, A KNUCKLE BOOM WAS ON SITE ENGAGED IN STEEL ERECTION OPERATIONS. THE KNUCKLE BOOM WAS HOLDING IN STEEL IN PLACE WHILE IT WAS BEING INSTALLED. NO CERTIFICATE OF ON SITE WAS PROVIDED AS REQ #39044627L | Sep 3, 2021 DEFAULT | $5,000 |
| Jul 19, 2021 | Construction CLASS - 1 AT TIME OF INSPECTION, A KNUCKLE BOOM CRANE WAS ON SITE ENGAGED IN STEEL ERECTION OPERATIONS(HOLDING STEEL IN PLACE WHILE IT IS BEING CONNECTED). A LICENSED OPERATOR IS REQUIRED FOR ANY KNUCKLE BOOM OPERATIONS #39044625H | Sep 3, 2021 DEFAULT | $12,500 |
| Jul 19, 2021 | Construction CLASS - 1 AT TIME OF INSPECTION, A KNUCKLE BOOM CRANE WAS ON SITE ENGAGED IN STEEL ERECTION OPERATIONS(HOLDING STEEL IN PLACE WHILE IT IS BEING CONNECTED). A LICENSED OPERATOR IS REQUIRED FOR ANY KNUCKLE BOOM OPERATIONS #39044626J | Sep 3, 2021 DEFAULT | $12,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.