Queens · Block 9177 · Lot 23 · 11418

84-40 101 Street

4 floors · 106,195 sq ft · built 2002 · class W1 · owner of record: Nyc School Construction Authority

23open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 106,195 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 9177). Agency page

Dec 31, 2027
in 431 days
Next due 2027
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-25 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (10)
IssuedViolationHearingBalance
Feb 25, 2026Construction CLASS - 2
REISSUE#35679013K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRESTOPPING PER BC 712.3;27-345.NOTED:AT CELLAR LEVEL HOLES LEFTOPEN IN GAS METER ROOM AND IN ELECTRICAL METER ROOM.REM:PROVIDE/MAINTA
#35729021N
Mar 12, 2026
POP/IN-VIO
$0
Feb 25, 2026Construction CLASS - 2
REISSUE#35691857M FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED AT THE CELLAR LEVEL BOILER ROOM WATER LEAKING THROUGH FOUNDATION WALL ONTO ELECTRICAL JUNCTION BOX ON THE WALL BEHIND BOILERS.REM:RE
#35729020L
Mar 12, 2026
POP/IN-VIO
$0
Mar 21, 2025Construction CLASS - 2
REISSUE#35679011R FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED AT CELLAR LEVEL BOILER ROOM,WATER LEAKING PIPE THROUGH FOUNDATION WALL & ONTO ELECTRICAL JUNCTION BOX ON THE WALL(BEHIND BOILERS).RE
#35691857M
Jul 8, 2025
POP/IN-VIO
$0
Mar 21, 2025Construction CLASS - 2
REISSUE#35679012L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED ROOF SURFACE WATERPROOF MEMBRANE BUILDING UP.PENTHOUSE WALL PANEL SYSTEM HAS GASKETS STARTING TO COME OUT BETWEEN SEAMS & WALL PANEL
#35691856K
Jul 8, 2025
POP/IN-VIO
$0
Apr 9, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712;27-345. CELLAR LEVEL HOLES LEFT OPEN IN GAS METER ROOM AND IN ELECTRICAL METER ROOM. REMEDY: PROVIDE/MAINTAIN FIRE STOPPING.
#35679013K
Sep 27, 2024
POP/IN-VIO
$0
Apr 9, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ROOF LEVEL LAYERS OF ROOF BUBBLING UP LAYERS SEPARATING, PANEL SYSTEM AROUND PENTHOUSE AREA BOTH SIDES OF ROOF GASKETS STARTING TO COME OUT BETWEEN SEAMS O
#35679012Z
Sep 27, 2024
POP/IN-VIO
$0
Apr 9, 2024Construction CLASS - 2
REISSUE: 35473300J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. CELLAR LEVEL IN BOILER ROOM WATER COMING THRU PIPES INTO ELECTRICAL JUNCTION BOX ONTO WALL. REMEDY: REPAIR AND/OR REPLACE.
#35679011R
Sep 27, 2024
POP/IN-VIO
$0
Mar 14, 2023Construction CLASS - 2
REISSUE #35548114J(2/16/21) FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT CELLAR LEVEL IN BOILER RM WATER INFILTRATION THROUGH WALL FROM CONDUITS PIPES FOR ELECTRICAL TO JUNCTION BOX ONTO WALLS & FLO
#35473300J
Jul 11, 2023
POP/IN-VIO
$0
Dec 20, 2021Boilers CLASS - 2
MISSING GLASS IN REAR OF BOILER,WISKA SWITCH FOR COMBUSTION AIR MISSING,EXPOSED WIRES,BOLT & DOG MISSING ON REAR DOOR
#39053165K
Jan 12, 2022
POP/IN-VIO
$0
Feb 16, 2021Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTE IN BOILERRM,BACK WALL BEHIND BOILER HAS WATER PENETRATING THRU WALL&APPEARS TO COME FROM JUNCTION BOX UNDER STORM DRAIN.REPAIR &/OR REPLACE&WATERPROOF WALL
#35548114J
May 25, 2021
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (13)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 9)
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:14 PM ET. BBL 4091770023.