Brooklyn · Block 1967 · Lot 68 · 11238

83 Lexington Avenue

2 floors · 17,000 sq ft · built 1965 · class I5 · owner of record: Nyc Department Of Homeless Services

9open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
788dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 788 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-06 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Feb 9, 2026Construction CLASS - 1
OBSERVED ON THE FIRST FLOOR STORAGE ROOM AND LAUNDRY ROOM, SPRINKLER HEADS ARE OBSTRUCTED. THROUGHOUT THE BUILDING, SPRINKLER HEADS ARE NOT FLUSHED TO CELLING WITH THE ESCUTCHEON PLATE, LEAVING AN UNSEALED CEIL
#39176641M
Apr 7, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 1
OBSERVED SLOP SINK ROOM, THERE IS NO FIRE STOP FOR THE PIPE PENETRATION THROUGH WALLS. THERE IS NO AIR GAP AT MOP SINK DRAIN LINE AND UNDER THE ICE MACHINE DRAIN LINE AND THE SPRINKLER SYSTEM DRAIN LINE. IN THE
#39176643X
Apr 7, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED ON THE GROUND FLOOR MAIN ENTRANCE METAL DETECTOR/ ITEM SCANNER BLOCKING EMERGENCY EXIT POTENTIAL HAZARD AND DANGER 27-369, BC 1020.2, REMOVE OBSTRUCTION
#39176607Z
Apr 7, 2026
POP/IN-VIO
$0
Feb 9, 2026Construction CLASS - 1
OBSERVED ON THE ROOF VENT TERMINAL NOT BEING SUPPORTED PROPERLY. ON FIRST AND SECOND FLOORS IN THE BATHROOMS NOT HAVING INSULATION ON TRAPS UNDER THE SINKS. IN THE SPRINKLER ROOM THE SPRINKLER SYSTEM IS BROKEN.
#39176642Y
Apr 7, 2026
POP/IN-VIO
$0
Apr 10, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED A FLEXGAS CORD ON A COMMERCIAL FIXED OVEN. POTENTIAL HAZARD., REPAIR AND/OR REPLACE
#39144706H
May 8, 2025
POP/IN-VIO
$0
Feb 6, 2019Boilers CLASS - 2
B254, 15, 32(A), 50. FOUND(WEILELAIN) MODEL #BL-788 BTUS 2,049,000 HOTWATER HEATING SYSTEM, AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTIAN, (15) OPENINGS IN WALLS, (32)A, EXPOSED WIRING,(50)MISSING SPILL
#32093180K
Jul 29, 2019
POP/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Dec 12, 2009ELEVATOR

#9028/321347
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#22828
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#23874
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 4, 2026, 7:13 PM ET. BBL 3019670068.