Brooklyn · Block 1647 · Lot 70 · 11221

827 Putnam Avenue

3 floors · 4 apartments · 3,360 sq ft · built 1931 · class C3 · owner of record: 827 Putnam, Llc

22open violations
$0ECB/OATH penalties owed
9HPD class C (immediately hazardous)
60dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 791 days
Next cycle year 2028

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
HPD (21) · C 9 · B 8 · A 4
IssuedClassViolationCorrect by
Jan 21, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.Apr 26, 2026
Jan 21, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED.Jan 27, 2026
Jan 21, 2026B§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE AND OR PAINTED SPRINKLER HEADS PUBLIC HALL ALL STYS.Feb 25, 2026
Jan 21, 2026B§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TREADS PULLING AWAY FROM STRINGER STAIRS 2 TO 12 2 TO 3 STY PUBLIC HALL.Feb 25, 2026
Jan 21, 2026BApt 2 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT 2 STY APT 2 DYSON. LOCATED AT APT 2Feb 25, 2026
Jan 21, 2026BApt 2 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES THRU OUT 2 STY APT 2 LOCATED AT APT 2Feb 25, 2026
Jan 21, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED CELLAR.Jan 27, 2026
Jan 21, 2026BApt 1 · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES BASEMENT APT 1 KITCHEN AND BATHROOM ER1 LOCATED AT APT 1Feb 25, 2026
Jan 21, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.Apr 26, 2026
Jan 21, 2026CApt 1 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES BASEMENT APT 1 KITCHEN AND BATHROOM ER1 LOCATED AT APT 1Jan 27, 2026
Jan 21, 2026B§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 100 WATTS OF INCANDESCENT LIGHT IS REQUIRED. (LIGHT FIXTURE PRESENT)Feb 25, 2026
Jan 21, 2026A§ 27-2005 ADM CODE PROVIDE PROPER SECURING OF SCUTTLE BY MEANS OF A SLIDE BOLT HOOK OR LOCK WHICH DOES NOT REQUIRE A KEY TO OPEN SCUTTLE COVER.Apr 26, 2026
Jan 21, 2026A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.Apr 26, 2026
Jan 21, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR CELLAR.Jan 27, 2026
Jan 21, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAILBOXES 1 STY PUBLIC HALL.Jan 27, 2026
Jan 21, 2026CApt 1 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM 1 STY APT 1. LOCATED AT APT 1Jan 27, 2026
Jan 21, 2026B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOOR PRESENTLY LOCKED PREVENTING ACCESS TO BASEMENT STY PUBLIC HALL.Feb 25, 2026
Jan 21, 2026BApt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK BATHROOM CEILING 2 STY APT 2. LOCATED AT APT 2Feb 25, 2026
Jul 28, 1998CApt 2 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT KITCHEN CEILING 2 STY APT 2 DYSON 573 6524 ER1 6213 LOCATED AT APT 2Aug 17, 1998
Jul 28, 1998CApt 2 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING REAR ROOM 2 STY APT 2 ER1 6213 LOCATED AT APT 2Aug 17, 1998
Jul 28, 1998CApt 2 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AND EAST WALL BATHROOM 2 STY APT 2 ER1 6213 LOCATED AT APT 2Aug 17, 1998

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 1:00 AM ET. BBL 3016470070.

Look up another building