3 floors · 8 apartments · 6,075 sq ft · built 1899 · class C1 · owner of record: Monmar Plaza L.P.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 791 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 1, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35584379N ISSUED ON 9/20/2021 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.BLOCKING EGRESS.REMEDY: #35564159N | Aug 1, 2022 IN VIOLATION | $625 |
| Aug 20, 2021 | Construction CLASS - 1 AT TIME OF INPSECTION OBSERVED THROUGH FRONT DOOR WINDOW A BIKE STORED IN FIRST FLOOR HALLWAY BLOCKING PARTIAL EGRESS FROM BACK APARTMENT.REMEDY:COMPLY WITH CODE. #35584379N | Mar 14, 2022 IN VIOLATION | $312 |
| Jul 3, 2021 | Construction CLASS - 1 AT TIMER OF INSPECTION OBSERVED STORED 3-BICYCLES AND A GARBAGE BAG IN FRONT OF APT # 1B ENTRANCE DOOR ON 1ST FLOOR PUBLIC HALLWAY WHICH IS PARTIALLY OBSTRUCTING EGRESS FROM APT # 1B., REMOVE OBSTRUCTION #39043919Z | Nov 3, 2021 IN VIOLATION | $312 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #22591 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 9, 2026 | C | Apt 1A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 23, 2026 |
| Sep 3, 2024 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS AT NORTH YARD | Sep 29, 2024 |
| Aug 29, 2024 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSISTING OF BOXES, GARBAGE BAGS AND A TENT AT NORTH YARD | Oct 3, 2024 |
| Jun 4, 2021 | C | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE AT BULKHEAD , 3rd STORY | Jun 30, 2021 |
| Jun 4, 2021 | C | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ENTRANCE , 1st STORY | Jun 30, 2021 |
| Nov 9, 2016 | A | Apt 3L3G · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE BELL AND RETURN BUZZER SYSTEM FROM BUILDING ENTRANCE TO APARTMENT LOCATED AT APT 3L3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 12, 2017 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 1:24 AM ET. BBL 3018180042.