Brooklyn · Block 5998 · Lot 43 · 11209

8106 5 Avenue

3 floors · 2 apartments · 3,600 sq ft · built 1921 · class S2 · owner of record: 8104-06 5th Avenue Realty Corp

25open violations
$0ECB/OATH penalties owed
4HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Jul 25, 2012Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT. NOTE: 1) AT TIME OF INSPECTION OBSERVED NEW LIGHT FIXTURE IN THE COMMERCIAL STORE W/O AN APP ON FILE OR PERMIT. 2) NEW SERVICES AT BASEMENT LEVEL W/O AN APP ON FILE. 3) OBSERVED -
#34945843M
Feb 4, 2013
WRITTEN OFF
$0
DOB (6)
IssuedViolationStatus
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#16845
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#17090
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#16663
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#17852
DOB VIOLATION - ACTIVE
Feb 13, 2004LOCAL LAW 62/91 - BOILERS

#19108
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#22513
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Jan 3, 2008Boiler LL6291
Active
Jan 19, 2007Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
Feb 13, 2004Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
HPD (12) · C 4 · B 7 · A 1
IssuedClassViolationCorrect by
Jan 15, 2020C§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING HEAVY DUTY MECHANICAL LOCKSET AT BUILDING ENTRANCE DOOR FROM STREET. , 1st STORYJan 23, 2020
Dec 31, 2019C§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LOCK AT BUILDING ENTRANCE DOORJan 8, 2020
Sep 9, 2019BApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING IN THE BATHROOM LOCATED AT APT 2, 3rd STORY ORIGINAL VIOLATION 13032273 ISSUED 23-APR-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).Oct 14, 2019
Apr 29, 2019BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOODEN SINK BASE CABINET IN THE BATHROOM LOCATED AT APT 2, 3rd STORYJun 3, 2019
Apr 29, 2019BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 2, 3rd STORYJun 3, 2019
Apr 29, 2019BApt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 3rd STORYJun 3, 2019
Apr 29, 2019C§ 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING SLIDING EYE BOLT WITH PADLOCK ON THE DOOR LEADING TO THE SCUTTLE LADDER AT PUBLIC HALL, 3rd STORYMay 7, 2019
Apr 29, 2019B§ 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT THE CEILING AND WEST WALL AT PUBLIC HALL, 3rd STORYJun 3, 2019
Apr 26, 2019A§ 27-2005 ADMIN. CODE: REFIT FRONT ENTRANCE DOOR TO BUILDING , 1st STORYJul 30, 2019
Oct 11, 2012BSECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT BLDG ENTRANCE DOORNov 15, 2012
Oct 11, 2012CSECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING LOCKABLE SLIDE BOLT AT SCUTTLE DOOROct 17, 2012
Oct 5, 2012BApt 3FL · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, APARTMENT AT WESTNov 9, 2012

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:57 PM ET. BBL 3059980043.

Look up another building