Manhattan · Block 875 · Lot 19 · 10003

81 Irving Place

16 floors · 102 apartments · 72,501 sq ft · built 1930 · class D4 · owner of record: Irving Tenants Corp

27open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-22 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 72,501 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 875). Agency page

Dec 31, 2035
in 3353 days
Next due 2035
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $216,000 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: UNSAFE (2025-09-23)

Open violations

ECB / OATH (4) · $10,000 owed
IssuedViolationHearingBalance
Aug 8, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALL(S) OR APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION OBSERVED(1) AT EXPO # EAST ELEVATION CRACK STONE ON BALCONY RAILING AND CRACK WINDOW GLASS AT SEVERAL LOCATIONS. (
#35718433X
Nov 13, 2025
IN VIOLATION
$0
Aug 16, 2019Construction CLASS - 1
PRESENCE AT SITE. NOTE: AT THE TIME OF MY INSPECTION OF A 16 STY BLDG AT BULKHEAD CONSTRUCTION WORK IN PROGRESS. UPON REQUEST OF THE SITE SAFETY MANAGER AS PER QSP(DANIEL AJPACAJA)HASNT ARRIVED YET & IS ON HIS
#35448216M
Oct 27, 2022
IN VIOLATION
$10,000
Aug 1, 2012Plumbing CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2 27-954 WITNESSED IN THE CELLAR BUILDING LAUNDRY ROOM HAS 4 GAS DRYERS & NO SPRINKLER
#34954612J
Dec 13, 2012
IN VIOLATION
$0
Aug 1, 2012Plumbing CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER RE: INSTALLATIONOF PLUMBING MATERIALS PER PC 102.3,27-902. WITNESSED IN THE CELLAR BUILDING LAUNDRY ROOM GAS PIPING FOR 4 COMMERCIAL GAS DRYERS HAVE 2
#34954613L
Dec 13, 2012
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Jun 1, 2019CONSTRUCTION
THE BORO COMMISSIONER HAS ISSUED A STOP WORK ORDER FOR APPLICATION #12 2707115 DUE TO APPLICANT WITHDRAWAL. STOP ALL WORK AND MAKE SITE SAFE REM: PROVIDE ALL THE REQUIRED INFORMATION FORTHWITH CONTACT THE BORO COMMISSIONER OFFICE AT 212-393-2615
#0613JL
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
HPD (21) · C 0 · B 14 · A 7
IssuedClassViolationCorrect by
Sep 24, 2009BApt 12E · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK CEILING SOUTHEAST ROOM 12 STY SOUTHEAST APT 12E. LOCATED AT APT 12EOct 29, 2009
Sep 24, 2009BApt 12E · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING SOUTHEAST ROOM 12 STY SOUTHEAST APT 12E. LOCATED AT APT 12EOct 29, 2009
Sep 24, 2009BApt 12E · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL SOUTHEAST ROOM 12 STY SOUTHEAST APT 12E. LOCATED AT APT 12EOct 29, 2009
Sep 24, 2009ASECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION WINDOW FRAMES SOUTHEAST ROOM 12 STY SOUTHEAST APT 12E.Dec 28, 2009
Sep 24, 2009AApt 12E · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILINGS & WALLS THROUGHOUT 12 STY SOUTHEAST APT 12E. LOCATED AT APT 12EDec 28, 2009
Sep 24, 2009AApt 12E · SECTION 27-2013 ADM CODE NO DECORATING IN 3 YEARS. REMOVE THE DIRTY AND/OR LOOSE PAPER AND REPAPER OR PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL CENTER ROOM WEST WALL PRIVATE HALL 12 STY SOUTHEAST APT 12E. LOCATED AT APT 12EDec 28, 2009
Sep 24, 2009BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS FIRE DOOR 8 STY EAST FIRE STAIR PUBLIC HALL.Oct 29, 2009
Sep 24, 2009BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS FIRE DOOR 5 STY WEST FIRE STAIR PUBLIC HALL.Oct 29, 2009
Sep 24, 2009BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS FIRE DOOR 2 STY EAST FIRE STAIRS PUBLIC HALL.Oct 29, 2009
Sep 24, 2009BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS FIRE DOOR 4 STY WEST FIRE STAIRS PUBLIC HALL.Oct 29, 2009
Sep 24, 2009ASECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DECK ERECTED 14 STY NORTHEAST CORNER OF TERRACE.Dec 28, 2009
Sep 24, 2009ASECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING BOILER ROOM CELLAR.Dec 28, 2009
Sep 24, 2009BApt 12E · SECTION 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE ,MISSING WASHBASIN IN THE BATHROOM LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHOct 29, 2009
Sep 24, 2009BApt 12E · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 12E, 12th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 29, 2009
Sep 24, 2009AApt 12E · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE STOPPER DRAIN BATHTUB BATHROOM, LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHDec 28, 2009
Sep 24, 2009BApt 12E · SECTION 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE SHUT OFF VALVE HOT AND COLD WATER HANDLES NORTH WALL ,BATHROOM LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHOct 29, 2009
Sep 24, 2009AApt 12E · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS THROUGH OUT LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHDec 28, 2009
Sep 24, 2009BApt 12E · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... NORTH WALL, AND CEILING 2ND ROOM FROM EAST AT SOUTH LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHOct 29, 2009
Sep 24, 2009BApt 12E · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, AND SOUTH WALL CLOSET, 2ND ROOM FROM EAST AT SOUTH LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHOct 29, 2009
Sep 24, 2009BApt 12E · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... EAST WALL FOYER LOCATED AT APT 12E, 12th STORY, APARTMENT AT SOUTHOct 29, 2009
Sep 24, 2009BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING LAUNDRY AREA CELLAR.Oct 29, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:40 AM ET. BBL 1008750019.