Manhattan · Block 93 · Lot 1 · 10038

81 Fulton Street

20 floors · 463,679 sq ft · built 1927 · class O4 · owner of record: 150 William Street Associates L.P.

16open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
170dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 49 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 463,679 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 170 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 170 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 780 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $57,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 832 days
Filing window not open yet
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 93). Agency page

Dec 31, 2033
in 2606 days
Next due 2033
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-29 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (8)
IssuedViolationStatus
Apr 12, 2022CONSTRUCTION
UNLSWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. ON APRIL 30, 2020 THE RESPONDENT WAS ORDERED TO IMMED HIRE A REG DESIGN PROF TO INSPECT THE ENTIRE BLDG AND FILE AND PERMIT ALL REPAIRS. AS OF THE DATE OF THIS VIOLATION, THERE ARE NO JOBS FILED OR PERMITS OBTAINED REMEDY: COMPLY WITH CODE
#CEU10101DA
DOB VIOLATION - ACTIVE
Feb 24, 2021ELEVATOR

#9027/697219
DOB VIOLATION - ACTIVE
Apr 30, 2020CONSTRUCTION
TIME OF INSPECTION-NUMBER OF LOCATIONS FIRE PROTECT STEEL STRUCTURAL ELEMENTS OF FLR FRAMING MISSING,OPENINGS IN CONCRTE FL SLABS MAY HAVE REDUCED REQUIRED FIRE RESISTANCE & BARRIER BTWN FLRS. OWNER IMNED HIRE REGISTRED DESIGN PROFESS,EXPERC'D W TYPE OF CONSTRCT.DESCRED-INSPECT G BLDG ENTIR,PREP DWG
#CEU10101DA
DOB VIOLATION - ACTIVE
Feb 18, 2020ELEVATOR

#9027/673158
DOB VIOLATION - ACTIVE
Jul 1, 1997LOCAL LAW 10/80 - FACADE

#NRF0403
DOB VIOLATION - ACTIVE
Jul 1, 1997LOCAL LAW 10/80 - FACADE

#NRF0401
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#00051
DOB VIOLATION - ACTIVE
Sep 21, 1992LOCAL LAW 5/73

#C301
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 12, 2026, 3:46 AM ET. BBL 1000930001.

Look up another building