6 floors · 228,000 sq ft · built 1967 · class G8 · owner of record: Vw Credit, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (7 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-05 (Accepted). Agency page | Dec 31, 2026 in 65 days | 1 of 7 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 228,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1084). Agency page | Dec 31, 2034 in 2987 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 21, 2018 | Elevators CLASS - 1 5A10 CEASE USE ITEM: DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND RENDERED INOPERATIVE. THIS IS A SAETY DEVICE TO ENSURE ELEVATOR PASSENGER'S SAFETY. REPAIR RESTRICTOR AND CONTACT NYCDOB AT EIR@BUI #38261049N | May 10, 2018 IN VIOLATION | $0 |
| Aug 25, 2015 | Boilers CLASS - 2 B254,32A,50,50A,50B,50C.50 DOOR HANDLES ON BOILER ROOM DOOR DEFECTIVE.50A DOOR HANDLES ON OIL STORAGE ROOM DEFECTIVE.50B OUTSIDE FRESH AIR INLET SCREEN 1/2 CLOSED.50C SUMP PUMP COVER NOT IN PLACE,BOLTS DEFECTIV #32075643Z | Jan 28, 2016 IN VIOLATION | $0 |
| Oct 25, 2012 | Elevators CLASS - 2 05L10. #1W6531 CAB SWING DOOR IS IMPROPER ALINGNMENT TO STRIKER POST. #38223823X | Dec 13, 2012 DEFAULT | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 2:41 AM ET. BBL 1010840001.