2 floors · 2 apartments · 2,665 sq ft · built 1920 · class B1 · owner of record: Livanos, Pantazis
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 309 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 11, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED AT EXPOSURE #1 CORNER #4, ADJOINING PROPERTY HAS FULL ACCESS TO ACTIVE JOBSITE. POSSIBILITY OF INJURIES EXISTS FOR THE PUBLIC. STOP ALL WORK SECURE JOBSITE FROM UNAUTHORIZED ACCE #39551512H | May 20, 2026 ADMIT/IN-VIO | $0 |
| Feb 27, 2026 | Unknown CLASS - 2 SUPPORTED SCAFFOLD NOT BUILT TO CODE. NETTING NOT SECURED BC 3314.8.2 PLANKS NOT TIED DOWN BC 3314.12.6 MISSING BRACING BC 3314.9 MISSING CROSS BRACES (STRUCTUAL INTEGRITY) BC 3314.4.1 COMPLY WITH CODE FOR INST #39551043Y | May 6, 2026 ADMIT/IN-VIO | $0 |
| Oct 1, 2025 | Construction CLASS - 1 REMOVED OR DEFACED A WRITTEN POSTED STOP WORK ORDER. VIO-# 39155996Z -ACTIVE STOP WORK /ISSUED ON 08/05/2025 HAS BEEN REMOVED W/O AUTHORIZATION BY DOB. NO RECORDS OF CORRECTIONS, COMPLY WITH CODE #39162118K | Jan 28, 2027 PENDING | $5,000 |
| Oct 1, 2025 | Construction CLASS - 1 ATOI OF A 3-STORY BLDG IT WAS OBSERVED THAT THE SITE WAS UNDER A FULL STOP WORK ORDER, SINCE O8/05/2025.BY BADGE:#2868-VIO-# 39155996Z UPON INSPECTION PERFORMED IT REVELED FAILURE TO COMPLY WITH. FULL STOP SWO@ #39162115P | Jan 28, 2027 PENDING | $10,000 |
| Aug 5, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION ON AN ACTIVE JOBSITE, I OBSERVED LARGE AMOUNTS OF DEBRIS SCATTERED THROUGHOUT SITE ALSO ON REAR YARD EXP#1/3.&BASEMENT LARGE AMOUNTS OF DEBRIS CREATE A TRIPPING HAZARD ALSO COULD CREATE A #39156012L | Nov 24, 2025 IN VIOLATION | $0 |
| Aug 5, 2025 | Unknown CLASS - 1 OBS PIPE SCAFFOLD @ 3 STORY BLDG.OBSERVED A PLATFORM BUILT ON OPEN SPACE MADE OF 2X4 & PLYWOOD SCAFFOLD CROSS BRACES CORRODED,UNTIED PLANKS, ALSO OBSERVED THAT THERE WERE MISSING PINS,MUDD SILLS GUARDRAILS ON P #39156014P | Nov 24, 2025 IN VIOLATION | $0 |
| Aug 5, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION ON A 3-STORY BUILDING, OBSERVED NO GUARD RAILS ON MULTIPLE LOCATIONS THROUGHOUT BUILDING, OPEN FLOORS, WINDOWS & BALCONIES.NO GUARDRAILS SYSTEMS CREATE A HAZARD FOR FALLS., PROVIDE GUARD R #39156031R | Nov 24, 2025 IN VIOLATION | $0 |
| Aug 5, 2025 | Construction CLASS - 1 ATIO ON AN ACTIVE JOBSITE, I OBSERVED THAT THE NO OHP @ ADJ PROPERTY IN PLACE OF ENTRANCE FOR PROPERTY AT EXP3&4# WAS SHORT BY #5 FEET AND DID NOT COVER THE ENTIRE DOOR ENTRANCE AS REQUESTED BY CODE. AND ADJACE #39156058R | Nov 24, 2025 IN VIOLATION | $0 |
| Aug 5, 2025 | Construction CLASS - 1 OBSERVED STRUCTURAL WORK IN PROGRESS BETWEEN FLOORS W/ TEMPORARY MAKESHIFT SHORING AT BUILDING TO SECURE/ SUPPORT FLOORS. WHILE REMOVING JOIST &ADDING 16''X20 BEAM NOT INDICATED, FAILURE TO PROVIDE PE APPROVED #39156039L | Nov 24, 2025 IN VIOLATION | $0 |
| Jun 25, 2025 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOSURE 1 WITH NO FENCE PROJECT INFO PANEL PROVIDED CONTRARY TO CODE 3301.9.1 FENCE PROJECT INFORMATION PANEL. WHERE A SITE IS ENCLOSED WITH A FENCE IN ACCORDANC #39541695K | Sep 3, 2025 ADMIT/IN-VIO | $0 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 12:25 PM ET. BBL 3059900044.