26 floors · 487,058 sq ft · built 1912 · class R0 · owner of record: Maple 80 Maiden Minority Owner, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 487,058 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $584,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 848 days | Filing window not open yet |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 42). Agency page | Dec 31, 2032 in 2257 days | Next due 2032 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 31, 2026 | Construction CLASS - 2 NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39177843P ISSUED 2/19/2026, CITING DAMAGED/REVERSED SPRINKLER HEADS, NO GAS SHUTOFF VALVE BEHIND GRILL, AND IMPROPERLY #39202444J | Nov 5, 2026 PENDING | $1,250 |
| Aug 31, 2026 | Construction CLASS - 2 NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-GROUND ELECTRICAL SYSTEMS VIOLATION #39177858H ISSUED 2/19/2026, CITING THE MAIN ELECTRICAL SYSTEM IN THE BASEMENT NOT GROUNDED TO THE MAIN #39202445L | Nov 5, 2026 PENDING | $1,250 |
| Aug 31, 2026 | Construction CLASS - 2 NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39177844R ISSUED 2/19/2026, CITING A WASTE LINE IN THE DEDICATED HIGH-VOLTAGE ELECTRICAL ROOM AND PIPES PENETRATING WAL #39202443H | Nov 5, 2026 PENDING | $1,250 |
| Aug 31, 2026 | Construction CLASS - 2 NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-INSTALL GROUNDING VIOLATION #39177857X ISSUED 2/19/2026, CITING NO GROUNDING ELECTRODE/GROUND ROD INSTALLED IN THE BASEMENT MAIN ELECTRICAL #39202446N | Nov 5, 2026 PENDING | $1,250 |
| May 28, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED AT EXP #2(EAST ELEV) CRACKED FACADEMASONRY BRICKS BETWEEN 4TH AND 10TH FLOOR. REMEDY: MAINTAIN EXTERIOR B #35729670N | Aug 20, 2026 IN VIOLATION | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Mar 9, 2022 | Facades FISPHAZ CYCLE 9C UNSAFE REPORT FILED | Active |
| Mar 9, 2022 | Facades FISPFCS CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 31, 2026 | ECB | Construction: NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39177843P ISSUED 2/19/2026, CITING DAMAGED/REVERSED SPRINKLER HEADS, NO GAS SHUTOFF VALVE BEHIND GRILL, AND IMPROPERLY | Open |
| Aug 31, 2026 | ECB | Construction: NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-GROUND ELECTRICAL SYSTEMS VIOLATION #39177858H ISSUED 2/19/2026, CITING THE MAIN ELECTRICAL SYSTEM IN THE BASEMENT NOT GROUNDED TO THE MAIN | Open |
| Aug 31, 2026 | ECB | Construction: NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39177844R ISSUED 2/19/2026, CITING A WASTE LINE IN THE DEDICATED HIGH-VOLTAGE ELECTRICAL ROOM AND PIPES PENETRATING WAL | Open |
| Aug 31, 2026 | ECB | Construction: NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-INSTALL GROUNDING VIOLATION #39177857X ISSUED 2/19/2026, CITING NO GROUNDING ELECTRODE/GROUND ROD INSTALLED IN THE BASEMENT MAIN ELECTRICAL | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 12:07 PM ET. BBL 1000427501.