Brooklyn · Block 2314 · Lot 122 · 11211

8 Havemeyer Street

6 floors · 13 apartments · 6,253 sq ft · built 2025 · class D3 · owner of record: 6 Havemeyer Street Llc

7open violations
$28,400ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 799 days
Next cycle year 2028

Open violations

ECB / OATH (13) · $28,400 owed
IssuedViolationHearingBalance
Oct 19, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 CONTRARY TO CODE 3307.6.4.4 VERTICAL MEMBERS AND BEAMS. ACTIVE DRIVEWAY AT EXPOS 2 VERTICAL MEMBERS WERE NOT PROTECTED FROM DISPLACEMENT WITH K
#39560768X
Dec 23, 2026
PENDING
$2,400
Oct 19, 2026Unknown CLASS - 2
UPON INSPECTION OF AN ACTIVE 6 STORY NB CONSTRUCTION SITE I OBSERVED A FLOOR OPENING ON THE 6TH INADEQUATELY COVERED. HOLE COVERING WAS NOT SECURED, 2IN THICK AND WAS NOT CLEARLY MARKED AS PER CODE 3306.9.10.3
#39560769H
Dec 23, 2026
PENDING
$2,500
Oct 19, 2026Site Safety CLASS - 1
UPON INSPECTION OF AN ACTIVE 6 STORY NB CONSTRUCTION SITE I OBSERVED EMBEDDED SAFETY STRAPS INSTALLED ON EVERY FLOOR IN USE. UPON REQUEST TO SEE THE INSTALLATION PHOTOS AND MAINTENANCE LOG (DOCS TO BE KEPT AND
#39560747R
Dec 23, 2026
PENDING
$2,500
Oct 19, 2026Construction CLASS - 2
I OBSERVED A FENCE INSTALLED AT EXPOS 1 WITH AN INADEQUATE FENCE PROJECT INFO PANEL INSTALLED. MISSING CONTENT REQUIRED BY CHAPTER 33 (CONTACT NUMBERS FOR THE OWNER AND GENERAL CONTRACTOR OF THE SITE, WEBSITE A
#39560762P
Dec 23, 2026
PENDING
$1,250
Oct 19, 2026Unknown CLASS - 2
UPON INSPECTION OF AN ACTIVE 6 STORY NB I OBSERVED A WINDOW AT EXPOSURE 3 WITH NO WINDOW PROTECTION PROVIDED CONTRARY TO CODE. INCOMPLETE AND ON GOING WORK WITHIN CLOSE PROXIMITY TO THE UNPROTECTED WINDOW IS A
#39560745N
Dec 23, 2026
PENDING
$2,500
Oct 19, 2026Construction CLASS - 1
I OBSERVED PIPE SCAFFOLD IN USE INSTALLED AT EXPOS 1, 2 AND 3 CONTRARY TO THE APPROVED DRAWINGS. NO DETAILS PROVIDED FOR 2FT PIPE SCAFFOLD USED AT EXPOS 3 ON THE 3RD FLR. PIPE SCAFFOLD BASE CONNECTION AT EXPOS
#39560744L
Dec 23, 2026
PENDING
$2,500
Oct 19, 2026Construction CLASS - 1
UPON INSPECTION OF AN ACTIVE 6 STORY NB CONSTRUCTION SITE I OBSERVED INADEQUATE AND POTENTIALLY HAZARDOUS HOUSEKEEPING PRACTICES ON THE 1ST FLOOR AT EXPOS 1. I OBSERVED ACCUMULATED COMBUSTIBLE MATERIAL AND DEBR
#39560756Z
Dec 23, 2026
PENDING
$2,500
May 13, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE, I OBSERVED CONSTRUCTION FENCE AROUND PERIMETER OF SITE COVER WITH EXCESSIVE GRAFFITI AND POSTERS UNRELATED CONSTRUCTION MATERIAL .
#39554068Y
Feb 2, 2027
$1,000
May 13, 2026Unknown CLASS - 2
NO WATCHPERSON BC 3303.3 AT THE TIME OF INSPECTION ON NON ACTIVE JOB SITE UNDER CONSTRUCTION APPROXIMATELY 5,409 SQUARE FEET. SITE WAS CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY UPON SHOUTING AND BANGING O
#39554069X
Feb 2, 2027
$2,500
Mar 6, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS.AT TIME OF INSPECTION,CONTRACTOR FAILED TO FILE A CERTIFICATE OF CORRECTION FOR VIOLATION#395
#39551358Z
Dec 18, 2026
$1,250
Jan 6, 2026Unknown CLASS - 1
BC 3310.4-SITE SAFETY MONITORING PROGRAM-OBSERVED ACTIVE 7 STORY 75' HIGH NEW BUILDING CONSTRUCTION JOB SITE ONLY CS DESIGNATED-AFTER REVIEWING DOB RECORDS PERMIT ISSUED ON 12/12/25-AS THE BUILDING IS PROPOSED
#39548839M
Oct 23, 2026
$5,000
Jan 6, 2026Construction CLASS - 2
AT THE TIME OF MY INSPECTION OF ACTIVE CONSTRUCTION JOB SITE OBSERVED SIDEWALK SHEDS INSTALLED AT EXP#1 -UPON ASKING COMPETENT PERSON FOR DAILY MAINTENANCE LOGS FOR SHED -NO ENTRY FOR INSPECTION OF SHED RECORDE
#39548784Y
Oct 23, 2026
$1,250
Aug 21, 2025Construction CLASS - 2
PROPOSED 8 STORIES NEW BUILDING CURRENTLY AT 3 STORIES AFTER REVIEW OF BIS AND DEPARTMENT OF BUILDINGS (DOB) SYSTEM RECORDS CONFIRMED THAT NO NEW BUILDING PERMIT HAD BEEN OBTAINED FOR ONGOING CONSTRUCTION WORK
#39543943J
Jan 15, 2027
$1,250
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 19, 2026ECBConstruction: UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 CONTRARY TO CODE 3307.6.4.4 VERTICAL MEMBERS AND BEAMS. ACTIVE DRIVEWAY AT EXPOS 2 VERTICAL MEMBERS WERE NOT PROTECTED FROM DISPLACEMENT WITH KOpen
Oct 19, 2026ECBUnknown: UPON INSPECTION OF AN ACTIVE 6 STORY NB CONSTRUCTION SITE I OBSERVED A FLOOR OPENING ON THE 6TH INADEQUATELY COVERED. HOLE COVERING WAS NOT SECURED, 2IN THICK AND WAS NOT CLEARLY MARKED AS PER CODE 3306.9.10.3Open
Oct 19, 2026ECBSite Safety: UPON INSPECTION OF AN ACTIVE 6 STORY NB CONSTRUCTION SITE I OBSERVED EMBEDDED SAFETY STRAPS INSTALLED ON EVERY FLOOR IN USE. UPON REQUEST TO SEE THE INSTALLATION PHOTOS AND MAINTENANCE LOG (DOCS TO BE KEPT ANDOpen
Oct 19, 2026ECBConstruction: I OBSERVED A FENCE INSTALLED AT EXPOS 1 WITH AN INADEQUATE FENCE PROJECT INFO PANEL INSTALLED. MISSING CONTENT REQUIRED BY CHAPTER 33 (CONTACT NUMBERS FOR THE OWNER AND GENERAL CONTRACTOR OF THE SITE, WEBSITE AOpen
Oct 19, 2026ECBUnknown: UPON INSPECTION OF AN ACTIVE 6 STORY NB I OBSERVED A WINDOW AT EXPOSURE 3 WITH NO WINDOW PROTECTION PROVIDED CONTRARY TO CODE. INCOMPLETE AND ON GOING WORK WITHIN CLOSE PROXIMITY TO THE UNPROTECTED WINDOW IS AOpen
Oct 19, 2026ECBConstruction: I OBSERVED PIPE SCAFFOLD IN USE INSTALLED AT EXPOS 1, 2 AND 3 CONTRARY TO THE APPROVED DRAWINGS. NO DETAILS PROVIDED FOR 2FT PIPE SCAFFOLD USED AT EXPOS 3 ON THE 3RD FLR. PIPE SCAFFOLD BASE CONNECTION AT EXPOSOpen
Oct 19, 2026ECBConstruction: UPON INSPECTION OF AN ACTIVE 6 STORY NB CONSTRUCTION SITE I OBSERVED INADEQUATE AND POTENTIALLY HAZARDOUS HOUSEKEEPING PRACTICES ON THE 1ST FLOOR AT EXPOS 1. I OBSERVED ACCUMULATED COMBUSTIBLE MATERIAL AND DEBROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 5:07 AM ET. BBL 3023140122.