Queens · Block 462 · Lot 53 · 11101

8-18 Queens Plaza South

9 floors · 34,251 sq ft · built 1965 · class HB · owner of record: Maruti Ravami Llc

26open violations
$5,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
165dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 34,251 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

On fileCycle 10 filing on record: SWARMP (2025-10-14)

Open violations

ECB / OATH (1) · $5,000 owed
IssuedViolationHearingBalance
Jan 7, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION I OBSERVED AT EX #1, EAST ELEVATION, UNSECURED ALUMINUM PANEL ATTACHED TO WALL BETWEEN 1ST FLOOR AND 4TH FLOOR. LOO
#35726345X
Apr 13, 2027
$5,000
DOB (13)
IssuedViolationStatus
Dec 1, 2022FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2201641
DOB VIOLATION - ACTIVE
Nov 2, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00486
DOB VIOLATION - ACTIVE
Aug 2, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00711
DOB VIOLATION - ACTIVE
Jun 1, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01104
DOB VIOLATION - ACTIVE
Feb 2, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00521
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2103062
DOB VIOLATION - ACTIVE
Nov 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00661
DOB VIOLATION - ACTIVE
Aug 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00940
DOB VIOLATION - ACTIVE
Jun 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01431
DOB VIOLATION - ACTIVE
Feb 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00901
DOB VIOLATION - ACTIVE
Nov 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01143
DOB VIOLATION - ACTIVE
Aug 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01680
DOB VIOLATION - ACTIVE
May 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#03047
DOB VIOLATION - ACTIVE
DOB NOW Safety (13)
IssuedViolationStatus
Dec 1, 2022Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 1, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Feb 2, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Feb 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 10:07 AM ET. BBL 4004620053.