4 floors · 73,705 sq ft · built 1928 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 73,705 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1165 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3782). Agency page | Dec 31, 2032 in 2261 days | Next due 2032 |
| Annual boiler inspection (4 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:GLASS WIREMESH STAIRWAY PARTITIONS CRACKED OR REPLACED WITH NON COMPLIANT MATERIALS(PLEXIGLASS OR MASORITE)ON STAIR G CELLAR LEVEL TO 1ST FL,STAIR H 2 #35722512X | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:ILLUMINATION DISCHARGE BOXES NOT FUNCTIONING WHEN TESTED ON BOX 5 STAI #35722516N | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 10, 2026 | Construction CLASS - 2 REISSUE ON ECB#35691622H ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2.NOTED:ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY #35722511Y | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 10, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOORS NOT SELF CLOSING PROPERLY DUE TO HARDWARE FAULTY OR BINDING ON EXIT DOORS EXIT 5.EXIT 11,AND EXIT 13.REM:REPAIR/REPLACE DOOR. #35722517P | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRE STOPPINGPER BC 712.3;27-345.NOTED:MISSING FIRESTOPPING IN SMALL ELECTRICAL SWITCH GEAR ROOM WITH VISIBLE THROUGH PENETRATION ON SEVERAL LOCATIONS TH #35722515L | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).NOTED:DOOR STOP/KICK STOPS INSTALLED ON SMOKE DOORS 2 DOORS ON GYM EMERGENCY SMOKE FIRE RAT #35722514J | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATEDCLASSROOMS AND SMOKE DOORS NOT SELF CLOSING DUE TO LACK OF HARDWARE,BINDING OR FAULTY HARDWARE ON CLASSROOMS,313,304,302,203,213,217,220,115 #35722513H | Mar 23, 2026 POP/IN-VIO | $0 |
| Mar 25, 2025 | Construction CLASS - 2 REISSUE#35678978M ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-188.3.1,28-118.3.2 TEMP COFO 402888121T004 EXP ON 1-16-2020.REM:OBTAIN A VALID COFO OR DISCONTINUE ILLEGAL #35691622H | Jul 8, 2025 POP/IN-VIO | $0 |
| Mar 14, 2024 | Unknown CLASS - 3 REISSUE#35665545Y ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2.NOTED:BUILDING OCCUPIED A PUBLIC SCHOOL.TEMP COFO#402888121T004 EXPIRED ON 01/16/2020.NO #35678978M | May 6, 2024 POP/IN-VIO | $0 |
| Feb 6, 2023 | Construction CLASS - 2 REISSUE#35635835P ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID COFO AS PER 28-118.3.1;28-118.3.2 NOTED:OBSERVED BUILDING OCCUPIED AS PUBLIC SCHOOL UNDER TEMPORARY COFO#402888121T004 EXPIRED AT 01/16/2020.R #35665545Y | May 9, 2023 POP/IN-VIO | $0 |
| Mar 7, 2022 | Construction CLASS - 2 REISSUED #35582314N ALTERED/CHANGED BUILDING OCCUPIED W/O VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1; 28-118.3.2 - NOTED: BUILDING OCCUPIED AS PUBLIC SCHOOL UNDER TEMPORARY C OF O #402888121T004 EX1/16/20 #35635835P | Jun 14, 2022 POP/IN-VIO | $0 |
| Jun 16, 2021 | Construction CLASS - 2 REISSUE#35498179H DATE OF ISSUE#06.03.2020 ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118-3.1-28-118.3.2 NOTED OBSERVED AT TIME OF INSPECTION TEMPORARY CERTIFICATE OF O #35582314N | Sep 28, 2021 POP/IN-VIO | $0 |
| Jun 3, 2020 | Construction CLASS - 2 REISSUE#35452284X ALTERED/CHANGED BLDG OCCUPIED W/O A VALID CERT OF OCCUPANCY AS PER 28-118.3.1;28-118.3.2. NOTED: OBSERVED AT TIME OF INSPECTION TEMPORARY CERT OF OCCUPANCY FOR P.S.087 EXP ON 1/16/20 RE: TCO# #35498179H | Sep 15, 2020 POP/IN-VIO | $0 |
| Sep 4, 2019 | Construction CLASS - 2 REISSUE #35346318X DATE OF ISSUE 07-09-2018 ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2 AT SCHOOL TCO EXPIRED AT TIME OF INSPECTION EXPIRED IN 2014 NO #35452284X | Dec 10, 2019 POP/IN-VIO | $0 |
| Jul 9, 2018 | Construction CLASS - 2 ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID COFO AS PER 28-118.3.1 28-118.3.2 NOTED: TCO EXPIRED AT TIME OF INSPECTION EXPIRED IN 2014. NO NEW COFO ISSUED. RMDY: COMPLY WITH CODE. #35346318X | Oct 23, 2018 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 9:24 PM ET. BBL 4037820027.