11 floors · 1,502,532 sq ft · built 1949 · class I1 · owner of record: Nyc Health And Hospitals Corporation
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 70 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 1,502,532 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $88,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 487 days | No Cycle 10 report on record yet |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1500). Agency page | Dec 31, 2030 in 1531 days | Next due 2030 |
| Annual boiler inspection (4 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-01 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 5, 2026 | Elevators CLASS - 2 THE ELEVATOR IN BUILDING OUT OF SERVICE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY 11- 02 . RESTORE TO SERVIVE IMMEDIATELY AND NOTIFY NYCDOB THE DEVIC #39179360J | May 12, 2026 DEFAULT | $1,562 |
| Sep 4, 2025 | Cranes and Derricks CLASS - 2 AT TIME OF INSPECTION OBSERVED: SUSPENDED SCAFFOLD USING OUTRIGGER AND C-HOOKS AT EXPOSURE# 1-2-4 UPON REVIEW DEPARTMENT RECORD IT APPEAR NOT NOTIFICATION FOR OUTRIGGER SUSPENDED SCAFFOLD, CREATING AN UNSAFE CO #39544477X | Nov 18, 2025 DEFAULT | $10,000 |
| Sep 4, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED: SUSPENDED SCAFFOLD USING OUTRIGGER AND C-HOOKS AT EXPOSURE# 1-2-4 UNSAFE CONTRARY TO CODE: SUSPENDED ELEMENTS NOT KEPT VERTICAL AND, IN A PLANE, PARALLEL TO THE WALL, JUMPING SET #39544476Y | Nov 18, 2025 DEFAULT | $10,000 |
| Sep 11, 2024 | Construction CLASS - 2 DURING INSPECTION I OBSERVED THAT THERE WAS NO INFO PANEL AFFIXED TO THE UPPER PANEL OF THE SIDEWALK SHED, WHICH IS REQUIRED BY CODE, FOR IDENTIFICATION OF THE SITE. OBTAIN AND INSTALL INFO PANEL AS REQUIRED. #39532285N | Nov 19, 2024 DEFAULT | $6,250 |
| Sep 11, 2024 | Construction CLASS - 2 DURING INSPECTION OF THE SIDEWALK SHED, I OBSERVED THAT THERE WERE NO LIGHTS BULBS INSTALLED UNDER THE SIDEWALK SHED. THE LACK OF LIGHTS CREATES A DARK AND POTENTIALLY DANGEROUS AREA FOR CRIME DURING DUSK AND D #39532284L | Nov 19, 2024 DEFAULT | $10,000 |
| Feb 11, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AS NOTED:AT TIME OF INSPECTION I OBSERVED ON EXPOSURE#1 SOUTH ELEVATION STEP CRACKS ON SOUTHWEST CORNER OF THE 8TH FL;BULGING DISINTEGRATING MASONR #35640146X | May 17, 2022 POP/IN-VIO | $0 |
| May 11, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: ROTTEN METAL LINTEL AND BRACES UNDER STAIRCASE AND LANDING AT NORTHEAST STAIRCASE NEXT TO ELEVATOR ON BROADWAY AND 78TH ST SIDE. AT THE TIME #35422489M | Aug 6, 2019 POP/IN-VIO | $0 |
| Mar 7, 2019 | Construction CLASS - 1 REISSUE VA 353813265. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: ROTTEN METAL LINTEL AND BRACES UNDSER STAIRCASE AND LANDING AT NORTHEAST STAIRCASE NEXT TO ELEVATORS ON BROADWAY AND #35401888R | Jun 4, 2019 POP/IN-VIO | $0 |
| Jan 11, 2019 | Construction CLASS - 1 REISSUE 35372953Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTE:ROTTEN METAL LINTELS AND BRACES UNDER STAIRCASE AND LANDING AT NORTHEAST STAIRCASE FROM 1ST FLOOR THRU 6TH FLOOR IN PARKING #35381326J | Apr 2, 2019 POP/IN-VIO | $0 |
| Nov 30, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: I OBSERVED ROTTED METAL LINTELS & BRACED UNDER CONCRETE STAIRCASE LANDINGS AT THE EAST SIDE STAIR WELL OF PARKING GARAGE FROM 1ST THRU 6TH FL OF STAIRWE #35372953Y | Feb 5, 2019 POP/IN-VIO | $0 |
| Oct 18, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED:I OBSERVED ROTTED METAL LINTELS AND ROTTED METAL BRACES UNDER CONCRETE LANDINGS AT EAST STAIR WELLS OF PARKING GARAGE FROM 1 TO 6 STORIES APPROX. 40 #35349215R | Dec 11, 2018 DEFAULT | $6,250 |
| Aug 1, 2018 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #810810.REM:FILE ACCEPTABLE REPORT #37012071X | Jan 22, 2019 POP/IN-VIO | $0 |
| Jan 25, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AT TIME OF INSPECTION, I OBSERVED ON EXPOSURE #1 SOUTH ELEVATION: - CRACKS AT SEVERAL FLOORS ALSO ON EXPOSURE #4 SOUTH ELEVATION. ROOF EXPOSURE: - #35265096P | Apr 3, 2018 POP/IN-VIO | $0 |
| Jan 25, 2018 | Construction CLASS - 1 FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE. AS PER 1RCNY 103.04. FACADE TECHNICAL REPORT FILE. UNSAFE BY PE/RA ON 01/23/18 AND NO AMENDED REPORT FILED AS OF 01/25/18 #35265089R | Apr 3, 2018 POP/IN-VIO | $0 |
| Feb 17, 2010 | Construction CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY ARTICLE 28.302 AND THE DOB RULES AND REGULATIONS. #36012062H | Dec 7, 2010 IN VIOLATION | $0 |
| Sep 30, 2008 | Cranes and Derricks CLASS - 2 FAILED TO NOTIFY DOB PRIOR THE INSTALLATION OF OUTRIGGER BEAMS IN CONNECTION OF SUSP SCAFFOLDS OBSERVED WORKERS ON SCAFFOLD SUSPENDED FROM OUTRIGGER BEAMS AT EXP 3 W/O NOTIFICATION REM: NOTIFY THE DEPT #34700169Y | Oct 13, 2009 IN VIOLATION | $0 |
| Sep 30, 2008 | Unknown CLASS - 1 LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKERS MET MINIMUM REQUIREMENTS. OBSERVED: WORKERS ON SCAFFOLD AT EXPOSURE 3 W/OU CERTIFICATE OF FITNESS. REMEDY: COMPLY W/THE CODE. #34700171N | Oct 13, 2009 IN VIOLATION | $0 |
| Sep 30, 2008 | Construction CLASS - 2 FAILURE TO PROVIDE APPROVED PLANS AT JOBSITE AT TIME OF INSP OBSERVED WORKERS ON SITE UNABLE TO PROVIDE CD5 FOR OUTRIGGER BEAMS USE REM: PROVIDE CD5 #34700170L | Oct 13, 2009 IN VIOLATION | $0 |
| Dec 21, 2007 | Construction Non-Hazardous ALTERED BLDG OCCUPIED W/O A VALID COFO NOTED:TEMPORARY COFO # 401382785T002 HAS EXP. ON 11.16.05 REMEDY:OBTAIN VALID COFO FOR CURRENT USE. #34621869J | Feb 10, 2009 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 28, 2023 | CONSTRUCTION AT THE TIME OF INSPECTION OF 6 FLOOR PARKING GARAGE I OBSERVED AT 2ND,3RD,4TH,5TH FLOORS AT 41 AVENUE SIDE CLOSE TO STAIRS, RUSTED STRUCTURAL LOAD BEARING STEEL BEAMS WITH CHUNKS SEPARATING AND FALLING #23-01250 | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #00487 | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #01227 | DOB VIOLATION - ACTIVE |
| Jan 23, 2018 | FACADE SAFETY PROGRAM #HAZ87099 | DOB VIOLATION - ACTIVE |
| Feb 28, 2002 | LL10/80-LOCAL LAW 10/80 - FACADE #HZ1110 | DOB VIOLATION - ACTIVE |
| Feb 6, 1997 | PLUMBING #OP ST OE 01 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 10/81 - ELEVATOR 14 #03838 | DOB VIOLATION - ACTIVE |
| Apr 7, 1992 | LOCAL LAW 10/81 - ELEVATOR 11 #04358 | DOB VIOLATION - ACTIVE |
| May 7, 1990 | ELEVATOR #1273D 01 | DOB VIOLATION - ACTIVE |
| May 7, 1990 | ELEVATOR #1273D 02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-HP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for HP Device | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-HP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for HP Device | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-HP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for HP Device | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
Showing 60 of 81. Full list on the agency site.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 10:25 PM ET. BBL 4015000002.