5 floors · 10 apartments · 21,000 sq ft · built 1930 · class D5 · owner of record: Aurora Associates Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 56 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2022-01-06 (Accepted). Agency page | Dec 31, 2026 in 56 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 72 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 787 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 31, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED FACADE AND CORNICE DEFECTS. MULTIPLE CRACKS, EXPANSION AT JOINTS ON READE ST., ROT WINDOW TRIMS, PIPE OUTSIDE WINDO #39093918M | Jul 18, 2024 IN VIOLATION | $625 |
| Jun 6, 2023 | Boilers CLASS - 2 HB SMITH BOILER NOT PROPERLY INSULATED. BOILER ROOM NOT FIRE RATED & THERE IS DEBRIS IN THE BOILER ROOM. CORRECT VIOLATING CONDITIONS & SUBMIT A CERTIFICATE OF CORRECTION. #39087879H | Oct 5, 2023 IN VIOLATION | $625 |
| Jan 26, 2019 | Construction CLASS - 2 ALTERED/CHANGED BLDG OCCUPIED W/O A VALID CERT OF OCCUPANCY AS PER 28-118.3.1;28-118.3.2. NOTED: AT TIME OF INSPECTION OBSERVED JOB#104715676 FILED TO ESTABLISH THE EXISTING USE & OCCUPANCY. HOWEVER BLDG IS OCC #35344539K | May 23, 2019 IN VIOLATION | $0 |
| Jun 23, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.DEFECT NOTED:AT EXPOSURE 1,SOUTH ELEVATION BETWEEN 2ND & 3RD FLS.1ST WINDOW FROM LEFT CORNER,MINOR CRACK GOING FROM ORNAMENTAL KEYSTONE T WINDOW SILL.AT FIR #35079600X | Aug 13, 2015 WRITTEN OFF | $0 |
| Apr 16, 2014 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. DEFECTS NOTED WOODEN INTERIOR PUBLIC STAR WHICH LEADS TO UPPER LEVEL APARTMENT IS LEANING APPROX 2-4 INCHES AND SAGGING OUT OF PLUM CAUSING STAIR TO PUL #35074053N | Aug 28, 2014 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #01697 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #01779 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #00095 | DOB VIOLATION - ACTIVE |
| May 13, 1991 | PLUMBING #011 | DOB VIOLATION - ACTIVE |
| Feb 28, 1991 | PLUMBING #011 | DOB VIOLATION - ACTIVE |
| Oct 15, 1990 | PLUMBING #011 | DOB VIOLATION - ACTIVE |
| Sep 21, 1990 | PLUMBING #06A | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 29, 2010 | B | Apt 4SW · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4SW, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 3, 2010 |
| Mar 29, 2010 | B | Apt 4SW · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 4SW, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 3, 2010 |
| Nov 23, 2004 | B | Apt 2A · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 2, 2005 |
| Nov 23, 2004 | B | Apt 2A · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 2, 2005 |
| Nov 23, 2004 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Mar 3, 2005 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 4:18 AM ET. BBL 1001500012.