Bronx · Block 4040 · Lot 1 · 10462

774 Van Nest Avenue

2 floors · 5 apartments · 3,600 sq ft · built 1931 · class S5 · owner of record: Javier, Ricardo

50open violations
$0ECB/OATH penalties owed
5HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 425 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-02 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (5)
IssuedViolationStatus
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#05958
DOB VIOLATION - ACTIVE
Dec 31, 2009LOW PRESSURE BOILER

#08571
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#09087
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#09066
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#09188
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
Dec 31, 2009Boiler LBLVIO
Active
Jan 1, 2009Boiler LL6291
Active
Jan 3, 2008Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
HPD (38) · C 5 · B 21 · A 9
IssuedClassViolationCorrect by
Feb 24, 2023I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Aug 9, 2016ISECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A V—
Jul 26, 2016ISECTION 27-2142 ADM CODE - THE PREMISES OR APTS. HAVE BEEN VACATED BY THE DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR 1R, VACATE # 131870 IN THE ENTIRE APARTMENT LOCATED AT CELLAR APT—
Apr 24, 2024BApt 1 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF DROP CEILING TILE DEFECTIVE IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 29, 2024
Apr 23, 2024BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2024
Apr 23, 2024BApt 1 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2024
Apr 23, 2024AApt 1 · § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 3rd ROOM FROM NORTH, THE PRIVATE HALLWAY , THE 2nd BATHROOM FROM NORTH, THE 1st BATHROOM FROM NORTH, THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESJul 27, 2024
Apr 22, 2024BApt 1 · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET COVER AT WEST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2024
Apr 22, 2024BApt 1 · § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS PANE MISSING AT UPPER SASH WINDOW WEST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2024
Apr 22, 2024BApt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2024
Apr 22, 2024BApt 1 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE INSTALLED VINYL TILE MISSIG IN THE KITCHENETTE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2024
Apr 18, 2024CApt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 14, 2024
Apr 18, 2024AApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2024
Apr 18, 2024AApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2024
Apr 18, 2024AApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2024
Apr 18, 2024BApt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 23, 2024
Apr 18, 2024BApt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 23, 2024
Apr 18, 2024CApt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 14, 2024
Apr 18, 2024BApt 1 · § 27-2005 HMC: REFIT UPPER SASH AT WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 23, 2024
Apr 11, 2023AApt 1 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJul 15, 2023
Feb 24, 2023A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME IS MISSING , 1st STORYMay 30, 2023
Feb 24, 2023CApt 1 · § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHFeb 24, 2023
Feb 24, 2023BApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMar 31, 2023
Feb 24, 2023AApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMay 30, 2023
Feb 24, 2023CApt 1 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDING 130 DEGREES IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMar 2, 2023
Oct 7, 2020BApt 1 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF (RACCOONS NESTING ABOVE DROP CEILING THRU-OUT) IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM SOUTH AT WESTNov 11, 2020
Oct 7, 2020BApt 1 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLETS AT THE EAST WALL (2) IN THE 1st ROOM FROM NORTH LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM SOUTH AT WESTNov 11, 2020
Oct 7, 2020AApt 1 · § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT DOOR & FRAME INTERIOR AT ENTRANCE LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM SOUTH AT WESTJan 10, 2021
Oct 7, 2020BApt 1 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF 2 SLIDING BOLTS WITH LOCKING EYE INSTALLED AT DOOR INTERIOR IN THE ENTRANCE LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM SOUTH AT WESTNov 11, 2020
Oct 7, 2020BApt 1 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT THE EAST WALL IN THE PRIVATE HALLWAY LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM SOUTH AT WESTNov 11, 2020
Jun 30, 2016BApt 1R · SECTION 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES WHERE ILLEGAL AND PROPERLY SEAL PIPE CONNECTIONS ... LOCATED AT CELLAR APT 1R, 1st CELLAR APT FROM EAST AT SOUTHAug 4, 2016
Jun 28, 2016BApt CC · SECTION 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES WHERE ILLEGAL AND PROPERLY SEAL PIPE CONNECTIONS APT 1R IN THE ENTIRE APARTMENT LOCATED AT APT CC, 1st APARTMENT FROM EAST AT SOUTHAug 2, 2016
Jul 2, 2007CApt 1 · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISNACE CONSISTING OF RODENTS RATS IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJul 13, 2007
Jul 2, 2007BApt 1 · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN THE BATHTUB IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 11, 2007
Sep 12, 2006BApt 3 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 22, 2006
Jul 31, 2006AApt 1 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE NORTH WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 8, 2006
Jul 20, 2006BApt 3 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTAug 29, 2006
Jul 20, 2006BApt 3 · SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT THE CEILING AND SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTAug 29, 2006

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 10:12 AM ET. BBL 2040400001.