Manhattan · Block 1840 · Lot 3 · 10025

77 West 104 Street

9 floors · 25 apartments · 32,981 sq ft · built 1926 · class D6 · owner of record: 77 West 104th St Assoc

107open violations
$13,750ECB/OATH penalties owed
18HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-02-22 (Accepted). Agency page

Dec 31, 2026
in 47 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 32,981 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $423,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 464 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029

Open violations

ECB / OATH (23) · $13,750 owed
IssuedViolationHearingBalance
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #906316. REMEDY: SUBMIT ACCEPTABLE REQU
#37027765M
Nov 6, 2025
DEFAULT
$6,250
Oct 20, 2020Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY : FILE APPLICATION, INSTALL DLM
#39030701N
May 6, 2021
IN VIOLATION
$1,250
Jul 15, 2020Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF K3 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGERS SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM AND PERFORM AND
#39025410R
Sep 16, 2021
DEFAULT
$6,250
Jul 6, 2017Construction CLASS - 1
FAILURE TO TAKE AND PROVIDE SAFETY MEASURES WHERE REQUIRED TO THE PROTECTION AND SECURED PUBLIC SAETY FROM UNSAFE FACADE AS PER 1RCNY 103-04 FACADE UNSAFE,FISP3 UNSAFE NOTIFICATION FILE BY PE/RA ON 5/27/17.RMDY
#35253639Y
Apr 26, 2018
WRITTEN OFF
$0
Mar 31, 2014Unknown CLASS - 1
215.2 FEEDER CONDUCORS SHALL BE SIZED SO THAT THE MAXIMUM VOLTAGE DROP@ THE LAST OVERCURRENT DEVICE DOES NOT EXCEED 3% & THE TOTAL MAXIMUM VOLTAGE DROP OF FEEDER AND BRANCH CIRCUIT CONDUCTORS TO THE LAST OUTLET
#35038909N
Jul 31, 2014
WRITTEN OFF
$0
Mar 31, 2014Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BLDG DEPT RECORDS DURING PHYSICAL INSPECTION I OBSERVED ONE LAUNDRY ROOM IN USE IN THE CELLAR CERTIFICATE OF OCCUPANCY SHOWS THERE ARE NO LA
#35066294Y
Jul 24, 2014
WRITTEN OFF
$0
Mar 31, 2014Construction CLASS - 1
WORK W/O A PERMIT ON 03/31/14 @ 2:00 P.M DURING PHYSICAL INSPECTION I OBSERVED 25 GAS METERS REMOVED IN THE CELLAR W/O A PERMIT ALSO NOTED NEW GAS LINES INSTALLED TO 4 MAYTAG DRYERS IN THE CELLAR LAUNDRY ROOM W
#35066291Z
Jun 26, 2014
WRITTEN OFF
$0
Mar 31, 2014Unknown CLASS - 2
FAILURE TO INSTALL GROUND-FRUIT CIRCUIT INTERRUPTION (GFCI)PROTECTION AS REQUIRED 9C KITCHEN:NO GFCI CIRCUIT PROVIDED.REM:INSTALL GFCI PROTECTION:
#35038913X
Jul 31, 2014
WRITTEN OFF
$0
Mar 31, 2014Plumbing CLASS - 1
FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.DURING PHYSICAL INSPECTION I OBSERVED 4 DRYERS & GAS LINES IN USE W/O GAS TEST DONE.AS PER N.Y.C FUEL GAS CODE ALL NEW OR ALTERED GAS PIPING MUST BE TESTED.
#35066295X
Jun 26, 2014
WRITTEN OFF
$0
Mar 31, 2014Unknown CLASS - 1
ELECTRICAL WORK W/O A PERMIT.THE ENTIRE APT9C & APT9B ONLY SUB PANEL:SUB PANELS BRANCH CIRCUIT WIRNG,RECEPTACLE OUTLETS,SWITCHES,LIGHTING FIXTURES.REM:OBTAIN PERMIT:
#35038908L
Jul 31, 2014
WRITTEN OFF
$0
Mar 31, 2014Unknown CLASS - 1
FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS.BSMT SERVICE EQUIPMENT:2.4000 AMPERS ARE NOT BONDED TO ENCLOSURES!!! REM: PROVIDE PROPER BONDING
#35038910K
Jul 31, 2014
WRITTEN OFF
$0
Mar 31, 2014Unknown CLASS - 1
250.64(D)THE EXOTHERMIC WELDING PROCESS.TOP CONDUCTORS SHALL BE CONNECTED TO THE COMMON GROUNDING ELECTRODE CONDUCTOR IN SUCH A MANNER THAT THE COMMON GROUNDING ELECTRODE CONDUCTOR REMAINS W/O A PLICE OR JOINT
#35038911M
Jul 31, 2014
WRITTEN OFF
$0
Mar 11, 2002Elevators Non-Hazardous
14M07/31Q07/62Q07/62K07/48R13/02L11/09H11/03I11/46R13/74D06/39H08/54T07/37B06/30O02/58O02/59O02/ 31-THRU OUT 62A,COVER MISSING 62B UNDERSIDE ROTTED 48 RESHACKLE 02-ALARM DOESE NOT SOUND WHEN STOP SW USED 03 REP
#38121267R
Apr 25, 2002
WRITTEN OFF
$0
Mar 11, 2002Elevators Non-Hazardous
73X07/ 73-RESTORE DEVICE TO SERVICE SO A COMPLETE INSP CAN BE DONE BY THIS DEPT CALL 6462488732 WHEN READY
#38121268Z
Apr 25, 2002
WRITTEN OFF
$0
Feb 7, 2002Elevators Non-Hazardous
73X11/ 75U5/ 73X11 = MAKE REPAIRS & RESTORE TO SERVICE FOR A FULL INSPECTION BY THIS DEPARTMENT
#38121277K
Mar 28, 2002
WRITTEN OFF
$0
Feb 7, 2002Elevators Non-Hazardous
(1)B11/ (3)I11/ (3)M7/ (9)H12/ 15L11/ (16)H12/ (17)A12/ (17)Q3/(22)I11/ (23)U16/ 23P17/ (32)Q3/ (31)Q3/ (35)I11/ 35O2/ 74M7/ 1B11 = ALLARM 3I11 = FLOOR 3M7 = CAPACOTY PLATE 15L11 = BSMT DOOR NOT
#38121278M
Mar 28, 2002
WRITTEN OFF
$0
Sep 26, 2001Elevators Hazardous
73D11/ 73L11/ 73X11 / 75B05
#38119181N
Nov 15, 2001
WRITTEN OFF
$0
Sep 26, 2001Elevators Non-Hazardous
9H12/ 17A12/ 17Q3/ 17I12/ 1B11/ 22I11/ <<<< SECONG OFFENCE 14I07/ 20X10/ 50D07/ 38X11/ 03B07/ 74#09
#38119180L
Nov 15, 2001
WRITTEN OFF
$0
Aug 28, 2001Elevators Non-Hazardous
1B11-9H12-17A12-17Q3-22I11-22Y2-23U16-31Q3-32Q3-35I11-3M7-16H12-53X11-75U5 1B11=ALARM 17A12=MUST BE WIREGLASS(CAR) 17Q3=CAR& ALL FLS 22I11=REPAIR & SECURE TO CODE 31Q3=CAR TOP 35I11=SKYLIGHT 3M7=CAPACITY PLATE
#38118731Y
Oct 18, 2001
WRITTEN OFF
$0
Jul 24, 2001Elevators Hazardous
7H12-17A12-17Q3-17I12-1B11-22I11-22Y2-25Q3-31Q3-35I11-23U16-50Y11-47B15-17M7 17A12=CAR 17Q3=CAR & ALL FLS 17I12=3 FL 1B11-ALARM 22I11=REPAIR& SECURE TO CODE 31Q3=CAR TOP 35I11=SKY LIGHT 17M7=CEASE USE CALL 212
#38117673K
Apr 18, 2002
WRITTEN OFF
$0
Jul 24, 2001Elevators Non-Hazardous
50Y11-73X11-75U5 73X11=MAKE REPAIRS & RESTORE TO SERVICE FOR A FULL INSPECTION BY THIS DEPARTMENT
#38117674M
Apr 18, 2002
WRITTEN OFF
$0
Dec 3, 1997Elevators Non-Hazardous
46L50Y50F06M57Z25D22D57O#M 46-CHANGE HOIST ROPES (50) SEAL MACHINE #50-REPAIR MACHINE CORRECT LOST MOTION 6-INSTALL GUARD ON CAR DOOR VISION GLASS #57-PUMP #COVE ELECT BOXES TOP OF CAR.
#38067579L
Mar 12, 1998
WRITTEN OFF
$0
Jan 29, 1993Elevators Non-Hazardous
14M,17I,0757O, 17. CAR PANEL CRACKED.
#38017191J
Apr 8, 1993
WRITTEN OFF
$0
DOB (31)
IssuedViolationStatus
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#01768
DOB VIOLATION - ACTIVE
Jan 20, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00080
DOB VIOLATION - ACTIVE
Oct 14, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00071
DOB VIOLATION - ACTIVE
Oct 4, 2017FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00069
DOB VIOLATION - ACTIVE
Nov 5, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00059
DOB VIOLATION - ACTIVE
Jul 2, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00109
DOB VIOLATION - ACTIVE
Jul 2, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00110
DOB VIOLATION - ACTIVE
Jul 2, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00106
DOB VIOLATION - ACTIVE
Jul 2, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00108
DOB VIOLATION - ACTIVE
Jul 2, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00107
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#01408
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#01409
DOB VIOLATION - ACTIVE
Mar 31, 2014PLUMBING
LAUNDRY ROOM INSTALLED IN THE CELLAR WITHOUT A PERMIT. 25 GAS METERS REMOVED IN CELLAR WITHOUT A PERMIT REMEDY: OBTAIN A PERMIT
#PL10704DG
DOB VIOLATION - ACTIVE
Nov 30, 2007LOCAL LAW 11/98 - FACADE

#NRF43966
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#06345
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#06346
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#05982
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#05983
DOB VIOLATION - ACTIVE
Jan 6, 1998LOCAL LAW 10/81 - ELEVATOR

#01206
DOB VIOLATION - ACTIVE
Sep 16, 1997LOCAL LAW 62/91 - BOILERS

#189015
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#08338
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#01555
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#01554
DOB VIOLATION - ACTIVE
Mar 8, 1996LOCAL LAW 10/81 - ELEVATOR

#01340
DOB VIOLATION - ACTIVE
Apr 17, 1995LOCAL LAW 10/81 - ELEVATOR

#01713
DOB VIOLATION - ACTIVE
Sep 1, 1994LOCAL LAW 62/91 - BOILERS

#06462
DOB VIOLATION - ACTIVE
May 31, 1994LOCAL LAW 10/81 - ELEVATOR

#01323
DOB VIOLATION - ACTIVE
Jul 1, 1992LOCAL LAW 10/80 - FACADE

#NRF0773
DOB VIOLATION - ACTIVE
Apr 7, 1992LOCAL LAW 10/81 - ELEVATOR
1
#01833
DOB VIOLATION - ACTIVE
Jun 29, 1990LOCAL LAW 10/81 - ELEVATOR
2
#02082
DOB VIOLATION - ACTIVE
Oct 12, 1989LOCAL LAW 10/81 - ELEVATOR
2
#02814
DOB VIOLATION - ACTIVE
DOB NOW Safety (31)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction
Active
Mar 6, 2026Energy Grade - LL33 FTP-EN-EGRDEA
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Jan 20, 2021AEUHAZ FTC-AEU-HAZ
Active
Oct 14, 2020AEUHAZ FTC-AEU-HAZ
Active
Jul 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
Active
Oct 4, 2017AEUHAZ FTC-AEU-HAZ
Active
Nov 5, 2014AEUHAZ FTC-AEU-HAZ
Active
Jul 2, 2014AEUHAZ FTC-AEU-HAZ
Active
Jul 2, 2014AEUHAZ FTC-AEU-HAZ
Active
Jul 2, 2014AEUHAZ FTC-AEU-HAZ
Active
Jul 2, 2014AEUHAZ FTC-AEU-HAZ
Active
Jul 2, 2014AEUHAZ FTC-AEU-HAZ
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Nov 30, 2007Facades LL1198
CYCLE 6 NO REPORT FILED
Active
Jan 19, 2007Boiler LL6291
Active
Jan 19, 2007Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Jan 6, 1998Elevators LL1081
Active
Sep 16, 1997Boiler LL6291
Active
Feb 10, 1997Boiler LL6291
Active
Jan 13, 1997Elevators LL1081
Active
Mar 8, 1996Elevators LL1081
Active
Apr 17, 1995Elevators LL1081
Active
Sep 1, 1994Boiler LL6291
Active
May 31, 1994Elevators LL1081
Active
Apr 7, 1992Elevators LL1081
Active
Jun 29, 1990Elevators LL1081
Active
Oct 12, 1989Elevators LL1081
Active
HPD (22) · C 18 · B 3 · A 1
IssuedClassViolationCorrect by
Jun 24, 2024CApt 9B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 20, 2024
Nov 27, 2023AApt 7B · § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 7B, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTMar 1, 2024
Nov 24, 2023BApt 7B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER WINDOW SASH AT 2ND WINDOW FROM WEST AT SOUTH IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7B, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 29, 2023
Nov 24, 2023BApt 7B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 7B, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 29, 2023
Nov 24, 2023BApt 7B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER WINDOW SASH IN THE KITCHEN LOCATED AT APT 7B, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 29, 2023
Apr 20, 2022CApt 9C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR LOOSE PLASTER AT THE CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 9C, 9th STORY, 1st APARTMENT FROM WEST AT NORTHApr 26, 2022
Apr 20, 2022C§ 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE ACCUMULATION OF WATER AT BOILER ROOMApr 26, 2022
Apr 20, 2022CApt 9A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 9A, 9th STORY, 1st APAApr 26, 2022
Apr 20, 2022CApt 9A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 3; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 9A, 9th STORY, 1st APAApr 26, 2022
Apr 20, 2022C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM AT LOCKED BOILER ROOM AT BOILER ROOMApr 26, 2022
Apr 20, 2022CApt 9B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM SOUTH AT WESTApr 26, 2022
Sep 10, 2019CApt 9A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM Oct 8, 2019
Sep 10, 2019CApt 9A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMTELY 10 SQ FT AT NORTH WALL , 12 SQ FT AT CEILING AND 20 SQ FT AT EAST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 1, 2019
Sep 10, 2019CApt 9A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 1, 2019
Sep 9, 2019CApt 9A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT EAST WALL, NORTH WALL IN THE FOYER LOCATED AT APT 9A, 9th STORY, 1st APAROct 7, 2019
Feb 25, 2019CApt 9A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM Mar 25, 2019
Feb 25, 2019CApt 9A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL, NORTH WALL, WEST WALL IN THE KITCHEN LOCATED AT APT Mar 25, 2019
Feb 25, 2019CApt 9A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 9A, 9th STORY, 1st APARTMMar 25, 2019
Oct 19, 2010CApt 9B · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ON CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 25, 2010
Oct 19, 2010CApt 9B · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING ,NORTH WALL AND CLOSET NORTH WALL IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 25, 2010
Sep 4, 2007CApt 2A · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 2A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 30, 2007
Sep 4, 2007CApt 2A · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) NORTH WALL IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 2A, 3rd STORY, 1st Sep 30, 2007

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 11:41 PM ET. BBL 1018400003.

Look up another building