Brooklyn · Block 4303 · Lot 36 · 11207

768 Miller Avenue

3 floors · 6 apartments · 4,685 sq ft · built 1930 · class C2 · owner of record: Garcia, Alicia

29open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
64dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-31 (Accepted). Agency page

Dec 31, 2026
in 64 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1160 days
Next cycle year 2029

Open violations

ECB / OATH (0)

None open.

DOB (3)
IssuedViolationStatus
May 4, 1998LOCAL LAW 62/91 - BOILERS

#25119
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#34413
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#33335
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 5)
Active
May 4, 1998Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
HPD (23) · C 1 · B 12 · A 10
IssuedClassViolationCorrect by
May 28, 2008AD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING CELLAR THROUGHOUT.Aug 31, 2008
May 28, 2008BD26-11.01, 11.03, 11.05 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE SEWAGE CELLAR THROUGHOUT.Jul 2, 2008
May 28, 2008AD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED CEILING CELLAR THROUGHOUT.Aug 31, 2008
May 28, 2008BD26-16.01 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN HOUSE SEWER CELLAR CENTER.Jul 2, 2008
May 28, 2008AD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE PARAPET BRACE ROOF FRONT.Aug 31, 2008
May 28, 2008BD26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE REAR ROOM 2ND STY FRONT APT.Jul 2, 2008
May 28, 2008AD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING HANDLE OF RADIATOR CONTROL VALVE 1 STY FRONT APTKITCHEN & FRONT ROOM.Aug 31, 2008
May 28, 2008ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.Aug 31, 2008
May 28, 2008BApt 1F · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 1 STY EAST APT 1F. LOCATED AT APT 1FJul 2, 2008
May 28, 2008BApt 1F · D26-16.01 ADM CODE REPAIR BY CLOSING SO AS TO BE GAS-TIGHT ALL OPENINGS IN THE WASTELINE UNDER SINK 1 STY EAST APT 1F KITCHEN. LOCATED AT APT 1FJul 2, 2008
May 28, 2008AApt 2F · D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC FLOOR TILE 2 STY EAST APT 2F BATHROOM. LOCATED AT APT 2FAug 31, 2008
May 28, 2008BApt 2F · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE FUSE BOX 2 STY EAST APT 2F FOYER. LOCATED AT APT 2FJul 2, 2008
May 28, 2008BApt 2R · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL UNDER SINK 2 STY WEST APT 2R KITCHEN. LOCATED AT APT 2RJul 2, 2008
May 28, 2008BApt 2R · D26-20.08 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 2 STY WEST APT 2R GAMONA. LOCATED AT APT 2RJul 2, 2008
May 28, 2008CApt 2R · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING 2 STY WEST APT 2R BATHROOM. LOCATED AT APT 2RJun 3, 2008
May 28, 2008AApt 2R · D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC FLOOR TILES 2 STY WEST APT 2R BATHROOM. LOCATED AT APT 2RAug 31, 2008
May 28, 2008BApt 2R · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 2 STY WEST APT 2R. LOCATED AT APT 2RJul 2, 2008
May 28, 2008AApt 2F · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 2 STY FRONT APT 2F CENTER ROOM. LOCATED AT APT 2FAug 31, 2008
May 28, 2008BApt 2F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL CEILING FIXTURE 2 STY FRONT APT 2F CENTER ROOM. LOCATED AT APT 2FJul 2, 2008
May 28, 2008BApt 2R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING THRU OUT 2 STY REAR APT 2R. LOCATED AT APT 2RJul 2, 2008
May 28, 2008AApt 2R · SECTION 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL 2 STY REAR APT 2R BATHROOM. LOCATED AT APT 2RAug 31, 2008
Jul 28, 2006ASECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING 1 STY PUBLIC HALLNov 24, 2006
Aug 11, 2005BSECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 1 STY PUBLIC HALLSep 20, 2005

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 11:44 AM ET. BBL 3043030036.