Bronx · Block 4289 · Lot 15 · 10462

762 Brady Avenue

6 floors · 55 apartments · 54,184 sq ft · built 1932 · class D4 · owner of record: 754 768 Brady Owners Corp

67open violations
$0ECB/OATH penalties owed
19HPD class C (immediately hazardous)
66dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 54,184 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 310 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 431 days
Next cycle year 2027
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4289). Agency page

Dec 31, 2029
in 1162 days
Next due 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-09 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Dec 9, 2022Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#912865.REMEDY:SUBMIT ACCEPTABLE REQUIRE
#37025067X
Mar 31, 2023
IN VIOLATION
$0
DOB (6)
IssuedViolationStatus
Dec 1, 2024FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2400930
DOB VIOLATION - ACTIVE
Dec 1, 2023FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2300942
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#01582
DOB VIOLATION - ACTIVE
Feb 13, 2004LOCAL LAW 62/91 - BOILERS

#07953
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#15299
DOB VIOLATION - ACTIVE
May 17, 1993LOCAL LAW 62/91 - BOILERS

#03754
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Dec 1, 2024Energy Grade - LL33 FTP-EN-EGRDEA
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Dec 1, 2023Energy Grade - LL33 FTP-EN-EGRDEA
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Sep 6, 2019Elevators ACC1
Active
HPD (53) · C 19 · B 24 · A 10
IssuedClassViolationCorrect by
Jun 5, 2026CApt 621 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 621, 6th STORY, 1st APARTMENT FROM NORTH AT EASTJun 11, 2026
May 5, 2022CApt 528 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 528, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH''May 11, 2022
Sep 22, 2016CApt 127 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHOct 20, 2016
Sep 22, 2016BApt 127 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHOct 27, 2016
Sep 22, 2016AApt 127 · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHDec 26, 2016
Sep 22, 2016BApt 127 · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING IN THE BATHROOM LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHOct 27, 2016
Sep 22, 2016AApt 127 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN , THE 4th ROOM FROM EAST LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHDec 26, 2016
Sep 12, 2016BApt 222 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND WINDOW FRAME IN THE 2nd BATHROOM FROM NORTH AT WEST LOCATED AT APT 222, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''BLDG 762''Oct 17, 2016
Sep 12, 2016BApt 222 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING STOPPER AT WASH BASIN SINK IN THE 2nd BATHROOM FROM NORTH AT WEST LOCATED AT APT 222, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''BLDG 762''Oct 17, 2016
Sep 12, 2016BApt 222 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE RADIATOR VALVE AT EAST IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 222, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 17, 2016
Sep 12, 2016BApt 127 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHOct 17, 2016
Jul 16, 2015BApt 127 · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ... CEILING IN THE BATHROOM LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHAug 20, 2015
Jul 16, 2015AApt 127 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE FOYER , THE 4th ROOM FROM EAST, THE KITCHEN LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHOct 19, 2015
Jul 2, 2008BApt 627 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 6TH STY NORTHEAST APT 627 BLDG 762. , SECTION '' ''Aug 6, 2008
Jul 2, 2008CD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE & OR FIRE DAMAGED WALLS FLOOR CLG DOORS & WINDOWS 4TH STY SOUTH CENTER APT 422 ENTIRE APT.Jul 8, 2008
Feb 16, 2007BApt 127 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SLOPING WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 127, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT NORTHMar 28, 2007
Dec 14, 2005CApt 222 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, WEST WALL IN THE KITCHEN LOCATED AT APT 222, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 9, 2006
Dec 14, 2005CApt 222 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 5th BATHROOM FROM EAST AT SOUTH LOCATED AT APT 222, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 9, 2006
Dec 14, 2005CApt 222 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, WEST WALL IN THE 5th ROOM FROM EAST AT NORTH LOCATED AT APT 222, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESJan 9, 2006
Feb 2, 2005AApt 321 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL IN THE KITCHEN LOCATED AT APT 321, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHMay 13, 2005
Feb 2, 2005AApt 321 · § 27-2005 ADM CODE REFIT LOWER SASH IN THE BATHROOM LOCATED AT APT 321, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 13, 2005
Feb 2, 2005BApt 321 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOODEN BASE WITHIN SINK. IN THE KITCHEN LOCATED AT APT 321, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTHMar 14, 2005
Aug 13, 2001C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ... AT BOILER ROOM, CELLARAug 24, 2001
May 23, 2001BApt 136 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL SINK BASE BUILDING #766 IN THE KITCHEN LOCATED AT APT 136, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHJul 2, 2001
May 23, 2001AApt 136 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BATHROOM VANITY DOORS BUILDING SECTION#766 IN THE BATHROOM LOCATED AT APT 136, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHAug 31, 2001
May 23, 2001BApt 136 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE BUILDING#766 IN THE BATHROOM LOCATED AT APT 136, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHJul 2, 2001
May 21, 2001CApt 136 · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK'S IN THE ENTRANCE LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJun 1, 2001
May 21, 2001BApt 136 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE OVEN IN THE KITCHEN LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJun 30, 2001
May 21, 2001CApt 136 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE REFRIGERATOR IN THE KITCHEN LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJun 1, 2001
Apr 18, 2001CApt 136 · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK'S IN THE ENTRANCE LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM NORTH AT EASTApr 29, 2001
Apr 18, 2001BApt 136 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER CABINET ROTTEN AND COLLAPSING. IN THE KITCHEN LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM NORTH AT EASTMay 28, 2001
Apr 2, 2001BApt 136 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMay 12, 2001
Apr 2, 2001AApt 136 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS \ CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJul 11, 2001
Apr 2, 2001BApt 136 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE OVEN OF GAS RANGE \ INOPERATIVE IN THE KITCHEN LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMay 12, 2001
Apr 2, 2001BApt 136 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHMay 12, 2001
Feb 22, 2001AApt 136 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT walls & ceilings ,trim IN THE ENTIRE APARTMENT LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''build 766'', AT SOUTHWESTJun 2, 2001
Feb 21, 2001BApt 136 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE FOYER LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''BULID766'', AT SOUTHWESTApr 2, 2001
Feb 21, 2001BApt 136 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR walls & ceilings IN THE ENTIRE APARTMENT LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''build 766''Apr 2, 2001
Feb 21, 2001BApt 136 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN roaches IN THE ENTIRE APARTMENT LOCATED AT APT 136, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''build766'', AT SOUTHWESTApr 2, 2001
Dec 17, 1999CApt 524 · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS ON A DETERIORATED SUBSURFACE THAT IS UNSTABLE OR UNSOUND USING EXCLUSIVE INTERIM CONTROLS. n/a EAST/SOUTH CEILING AT SOUTH IN THE 1st ROOM FROM SOUTH LOCATED AT APT 524 UPPER LEVEL, 5th STORY, 2nd APARTMENT FROMJan 17, 2000
Dec 8, 1999CApt 524 · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS ON A DETERIORATED SUBSURFACE THAT IS UNSTABLE OR UNSOUND USING EXCLUSIVE INTERIM CONTROLS. n/a NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 524 UPPER LEVEL, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST , Feb 11, 2000
Dec 8, 1999AApt 524 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION drop ceing thru out apt IN THE ENTIRE APARTMENT LOCATED AT APT 524 UPPER LEVEL, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''souMar 17, 2000
Dec 1, 1999CApt 524 · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS ON A DETERIORATED SUBSURFACE THAT IS UNSTABLE OR UNSOUND USING EXCLUSIVE INTERIM CONTROLS. CEILING CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 524, 5th STORY, APARTMENT AT WEST , SECTION ''762'', AJan 1, 2000
Dec 1, 1999CApt 524 · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS ON A DETERIORATED SUBSURFACE THAT IS UNSTABLE OR UNSOUND USING EXCLUSIVE INTERIM CONTROLS. AT NORTH WALL IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 524, 5th STORY, APARTMENT AT WEST , SECTION ''762'', AT Jan 1, 2000
Dec 29, 1998CApt 529 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE EXTERIOR BRICK JOINTS NORTH SOUTH ESAT WALL 5TH STY SOUTHWEST APT 529 SOUTHEAST ROOM.A2 , SECTION '' ''Jan 18, 1999
Dec 29, 1998CApt 529 · § 27-2005 ADM CODE REPAIR AND OPERATE THE GAS APPLIANCE SO AS TO PREVENT CARBON MONOXIDE COUNTER BALANCE WINDOW 5TH STY SOUTHWEST APT 529 THRU OUT. , SECTION '' ''Jan 18, 1999
Dec 24, 1996B§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER WINDOW SASH 2ND STY 1ST APT FROM SOUTH AT WEST APT 223 CENTER ROOM.Feb 10, 1997
Dec 24, 1996BApt 223 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNLEVEL WOOD FLOOR 2ND STY 1ST FROM SOUTH AT WEST APT 223 KITCHEN. LOCATED AT APT 223Feb 10, 1997
Dec 24, 1996BApt 223 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNLEVEL WOOD FLOOR 2ND STY 1ST FROM SOUTH AT WEST APT 223 CENTER ROOM. LOCATED AT APT 223Feb 10, 1997
Dec 24, 1996AApt 223 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WARPED WOOD FLOOR 2ND STY 1ST FROM SOUTH AT WEST APT 223 PRIVATE HALL. LOCATED AT APT 223Apr 11, 1997
May 24, 1994C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT BLDG ENTRANCE DOOR.Jun 13, 1994
May 24, 1994B§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WIRE SCREEN BELOW THE SKYLIGHT BULKHEAD 6TH STY PUB HALL STAIRS TO ROOF.Jul 11, 1994
Jan 3, 1989CApt 627 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CLG 6 STY NORTHEAST APT 627 NORTHEAST ROOM ER1. , SECTION '' ''Jan 23, 1989

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 9:04 PM ET. BBL 2042890015.

Look up another building