31 floors · 300 apartments · 252,500 sq ft · built 1974 · class D4 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 1994-05-31 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 63 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 79 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 252,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 184 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 184 days | Annual filing |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2007). Agency page | Dec 31, 2027 in 428 days | Next due 2027 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1159 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-21 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | On file | Cycle 10 filing on record: UNSAFE (2025-11-03) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 27, 2026 | Construction CLASS - 2 AT TIME RESPONDING INCIDENT OBSERVED: SIDEWALK SHED AT EXPO# 3 WITH PARAPET PARTIALLY COLLAPSED 80 FEET APPROX. CREATING AN UNSAFE CONDITION FOR PEDESTRIANS AND DAMAGING VEHICLES AT PARKING LOT AREA. STOP ALL F #39559859N | Dec 2, 2026 PENDING | $5,000 |
| Aug 1, 2026 | Unknown CLASS - 1 BC3314.10.13 AT TIME OF INSPECTION OBSERVED SUSPENDED SCAFFOLD AT EXP#1 2 3 4 NOT IN USE AND NOT LOWERED TO THE GROUND OR DECK AS REQUIRED BY CODE. SUSPENDED SCAFFOLD PARKED AT 1ST FLOOR BUILDING WALL. UPON REV #39557393L | May 7, 2027 | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| May 28, 2026 | CONSTRUCTION EWO DUE TO LARGE CRACK IN MASONRY WALL ON BULKHEAD ON EXP 1 W.ELEV SHOWS SIGNS OF MAJOR MASONRY MOVEMENT BRICKS HAVE COMPLETELY SEPARATED FROM MORTAR JOINTS. RMDY:IMMEDLY RETAIN A NYS RDP TO DIRECT & SUPERVIS THE IMMEDTE STABILZTN OF THE MASONRY & REMOVAL OF ALL LOOSE MATERIAL INSTALL SFTY MEAS AS P #SR30202XN | DOB VIOLATION - ACTIVE |
| Jun 17, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED MULTIPLE DEFECT THE MAINT AND SET BACK ROOF. CRACKS/STEP CRACKS AND BULGING BRICKS ALSO DAMAGED AND OPEN MORTAR JOINTS. REMEDY: MAINTAIN BUILDING REPAIR AND/OR REPLACE #SR0201NS | DOB VIOLATION - ACTIVE |
| May 28, 2025 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO LARGE CRACK IN MASONRY WALL ON BULKHEAD AS NOTED LARGE CRACK ON MASONRY WALL ON BULKHEAD ON EXP1 W ELEV. CRACK IS LOCATED ON CORNER EDGE OF BULKHEAD SIGNS OF MAJOR MASON MOVEMENT BRKS SEPARATED.REMEDY:RETAIN NYS RDP IMMED STABILIZATION OF MASONRY & REMOVE LOOSE MATERIAL R #SR30202XN | DOB VIOLATION - ACTIVE |
| May 28, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLAINT MANNER. OBSERVED LARGE CRACK ON BULKHEAD ON EXPOSURE 1 WEST ELEVATION. REMEDY: REPAIR AND/OR REPLACE #SR30203XN | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #00398 | DOB VIOLATION - ACTIVE |
| Oct 28, 2019 | FACADE SAFETY PROGRAM #HAZ88419 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #35197 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Oct 28, 2019 | Facades FISP CYCLE 8B UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 27, 2014 | B | Apt 3K · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY | Mar 3, 2014 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 27, 2026 | ECB | Construction: AT TIME RESPONDING INCIDENT OBSERVED: SIDEWALK SHED AT EXPO# 3 WITH PARAPET PARTIALLY COLLAPSED 80 FEET APPROX. CREATING AN UNSAFE CONDITION FOR PEDESTRIANS AND DAMAGING VEHICLES AT PARKING LOT AREA. STOP ALL F | Open |
| Aug 1, 2026 | ECB | Unknown: BC3314.10.13 AT TIME OF INSPECTION OBSERVED SUSPENDED SCAFFOLD AT EXP#1 2 3 4 NOT IN USE AND NOT LOWERED TO THE GROUND OR DECK AS REQUIRED BY CODE. SUSPENDED SCAFFOLD PARKED AT 1ST FLOOR BUILDING WALL. UPON REV | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)