50 floors · 1,824,820 sq ft · built 1968 · class O4 · owner of record: 767 Fifth Partners Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $10,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 117 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 1,824,820 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1161 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1294). Agency page | Dec 31, 2034 in 2987 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 16, 2026 | Construction CLASS - 2 STOP ALL SUSPENDED SCAFFOLD USE ENTIRE SITE. COUNTER WEIGHTS WERE INSTALLED CONTRARY TO THE DESIGN DRAWINGS MISSING ONE 50.LB PLATE USED TO BALANCE ADJUSTABLE SUSPENSION SCAFFOLDS THAT SHALL BE CAPABLE OF RESIS #39555782X | Aug 27, 2026 IN VIOLATION | $625 |
| Jun 16, 2026 | Construction CLASS - 1 STOP ALL FACADE OPERATIONS ENTIRE. I OBSERVED A 50 STORY BUILDING UNDERGOING FACADE OPERATIONS WITH SUSPENDED SCAFFOLDS IN PLACE. MY INSPECTION REVEALED THAT SUSPENDED SCAFFOLD WORKERS HAVE NOT RECEIVED A SITE #39555783H | Aug 27, 2026 IN VIOLATION | $2,500 |
| Mar 9, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION,CONTRACTOR FAILED TO FILE A CERTIFICATE OF CORRECTION FOR VIOLATION #3 #39551564J | Dec 18, 2026 PENDING | $1,250 |
| Jan 21, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION-OBSERVED SHED BEING INSTALLED AT EXP#3 -UPON CHECKING PLANS VERTICAL POSTS OF SIDEWALK SHED SHALL BE SQUARE 4"X4"-INSTALLED ARE SQUARE POSTS- 3"X3"-HAZARDOUS CONDITION OF COLLAPSE O #39549374X | Dec 3, 2026 | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2022 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2200327 | DOB VIOLATION - ACTIVE |
| Nov 12, 2015 | ELEVATOR #9028/551890 | DOB VIOLATION - ACTIVE |
| Nov 12, 2015 | ELEVATOR #9028/544549 | DOB VIOLATION - ACTIVE |
| Feb 18, 2013 | ELEVATOR #9028/430036 | DOB VIOLATION - ACTIVE |
| Jul 12, 2011 | ELEVATOR #9027/389459 | DOB VIOLATION - ACTIVE |
| Jul 12, 2011 | ELEVATOR #9027/389454 | DOB VIOLATION - ACTIVE |
| Jun 9, 2005 | CONSTRUCTION #0501DM | DOB VIOLATION - ACTIVE |
| Jun 1, 2001 | ELEVATOR 1P22656 #9444/140155 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01124 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01125 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Dec 1, 2022 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |