5 floors · 115,000 sq ft · built 1936 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 115,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 430 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6239). Agency page | Dec 31, 2029 in 1161 days | Next due 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 10, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: AT(1ST FL) STAIRS D, F, AND I DOORSIN DISREPAIR/NOT CLOSING WHEN TESTED. REMEDY: REPAIR/REPLACE DOOR. #35728747H | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT(2ND FL) AUDITORIUM STAIRS E AND F DOORS IN DISREPAIR/RACKED. REMEDY: REPAIRAND/OR REPLACE. #35728746X | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 10, 2026 | Construction CLASS - 2 REISSUE ECB #35691654P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT(4TH FL) CLASSROOM #410 WITH WATER DAMAGE TO CEILING/WALL CRACKS/SPALLING/STAINING PLASTER/PAINT. REMEDY: COMPLY WITH CODE. #35728744M | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: AT(1T FL) GYMS, CAFETERIA(2ND FL) AUDITORIUM EMERGENCY LIGHTS NO #35728745Y | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 21, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: OBSERVED 5 LIGHTS IN THE AUDITORIUM, 5 LIGHTS ABOVE ROOM 205, AN #35691635R | Apr 28, 2025 POP/IN-VIO | $0 |
| Feb 21, 2025 | Construction CLASS - 2 RE-ISSUE #35676268Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED IN CLASSROOM #410, THERE ARE MULIPLE CRACKS AND WATER PENETRATION IN THE CEILING NEXT TO THE WINDOW. REMEDY: REPAIR AN #35691634P | Apr 28, 2025 POP/IN-VIO | $0 |
| Feb 26, 2024 | Construction CLASS - 2 REISSUE #35665738R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. SEVERAL CLASSROOM SHOWER SIGNS AS WATER-PENETRATION LEAD TO DAMAGED TO CEILING AND WALLS IN ROOM # 400B, 410 AND 408A. REMEDY: REPAIR A #35676268Z | May 6, 2024 POP/IN-VIO | $0 |
| Jan 24, 2023 | Construction CLASS - 2 REISSUE#35650852M.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE OBSERVED ON 4TH FLOOR CLASSROOM#408A,408B AND 410 CEILING AND WALLS SHOWING SIGNS OF WATER PENETRATION AND DAMAGE TO THE PLASTER.REME #35665138R | May 10, 2023 POP/IN-VIO | $0 |
| May 2, 2022 | Boilers CLASS - 2 MISSING SHUT OFF VALVE ON OIL TANK. THREE SHUT OFF VALVES LEAKING IN BACK OF BOILER #1 #39061384K | May 11, 2022 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 6, 1999 | CONSTRUCTION #SSBL01 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 10:35 AM ET. BBL 3062390001.