Manhattan · Block 1109 · Lot 100 · 10019

755 12 Avenue

75,562 sq ft · built 2002 · class T9 · owner of record: Nys Department Of Environmental Conservation

1open violations
$37,530ECB/OATH penalties owed
0HPD class C (immediately hazardous)
61dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 61 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2018-09-19 (Accepted). Agency page

Dec 31, 2026
in 61 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 75,562 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 182 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 182 days
Annual filing
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1109). Agency page

Dec 31, 2029
in 1157 days
Next due 2029

Open violations

ECB / OATH (6) · $37,530 owed
IssuedViolationHearingBalance
Aug 4, 2025Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER FELL WHILE PERFORMING WELDING OPERATION ON AN ELEVATED WALKING PLATFORM, UPON REQUEST FOR WELDING LICENSE FOR WORKER PERFORMING MANUAL WELDING OPERATION NONE WAS PROVIDE
#39543234R
Nov 19, 2026
$2,500
Aug 4, 2025Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER FELL APPROXIMATELY 38 FEET FROM ELEVATED PLATFORM. INSPECTION REVEALS THAT 4 WORKERS WERE USING AND OPERATING THE SCISSOR LIFT, UPON REQUEST FOR CERTIFICATES ONLY ONE WO
#39543235Z
Nov 19, 2026
$2,500
Aug 4, 2025Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER FELL APPROXIMATELY 38 FEET FROM ELEVATED PLATFORM. INSPECTION REVEAL THAT PRE SHIFT SAFETY MEETING FAILED TO COMMUNICATE SCOPE OF WORK AND HAZARDS, NO GUARDRAILS WERE PR
#39543236K
Nov 19, 2026
$10,000
Aug 4, 2025Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER FELL APPROXIMATELY 38 FEET FROM ELEVATED PLATFORM. INSPECTION REVEAL THAT PRE SHIFT SAFETY MEETING FAILED TO COMMUNICATE SCOPE OF WORK AND HAZARDS, NO GUARDRAILS WERE PR
#39543233P
Nov 19, 2026
$10,000
Aug 4, 2025Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER FELL APPROXIMATELY 38 FEET FROM ELEVATED PLATFORM. INSPECTION REVEALED THAT HOT WORK OPERATIONS WERE ONGOING AT THE TIME OF THE FALL, DESPITE AN ACTIVE STOP WORK ORDER (
#39543232N
Nov 19, 2026
$10,000
Jan 22, 2025Construction CLASS - 1
AT TIME OF INSPECTION OF AN ACTIVE JOBSITE I OBSERVED SCISSORS LIFTS IN OPERATION WITH PEOPLE WALKING, STANDING ADJACENT TO IT, WITHOUT BARRIERS OR CONTROL ACCESS ZONE INITIATED TO PREVENT FALLING OBJECT FROM
#39536187H
Feb 4, 2027
$2,530
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 8:00 AM ET. BBL 1011090100.