Bronx · Block 2517 · Lot 1 · 10452

75 West 168 Street

4 floors · 90,748 sq ft · built 1950 · class W2 · owner of record: Rc Ch Sacred Heart

40open violations
$13,025ECB/OATH penalties owed
0HPD class C (immediately hazardous)
60dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 60 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 90,748 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 181 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 181 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2517). Agency page

Dec 31, 2027
in 425 days
Next due 2027
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-16 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (9) · $13,025 owed
IssuedViolationHearingBalance
Oct 1, 2026Unknown CLASS - 2
ELECTRICAL WORK DOES NOT CONFORM TO APPROVED SUBMITTAL DOCUMENTS/AMENDMENTS. OBSERVED ON 2ND, 3RD FL ELECTRICAL CLOSET NEW 12 / 24 PANELS INSTALLED WITH NEW OVERCURRENT PROTECTION. PERMIT # X01442199 DOES NOT C
#39206332N
Dec 18, 2026
PENDING
$1,250
Oct 1, 2026Unknown CLASS - 2
FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. OBSERVED IN ELECTRICAL PANELS FOR THE 2ND, 3RD FL'S NO ARC FAULT PROTECTION FOR NEW A/C LINES FOR ALL CLIENTS ROOMS. ARC FAU
#39206333P
Dec 18, 2026
PENDING
$2,400
Oct 16, 2025Elevators CLASS - 1
RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION
#39163825Y
Apr 1, 2027
DEFAULT
$6,250
Oct 16, 2025Elevators CLASS - 1
RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION
#39163826X
Apr 10, 2026
IN VIOLATION
$3,125
Jan 13, 2025Elevators CLASS - 1
: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION PER 1RCNY
#39135345R
Sep 22, 2025
IN VIOLATION
$0
Aug 21, 2024Elevators CLASS - 1
: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION PER 1RCNY
#39122622N
Sep 22, 2025
IN VIOLATION
$0
Mar 16, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER;LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER BC 1006.1;27-542. NOTED: THE FOLLOW EMERGENCY LIGHTS & SIGN ARE NOT WORKING WHEN TES
#35234687P
Jun 8, 2018
IN VIOLATION
$0
Mar 16, 2017Construction CLASS - 3
FAILURE TO MAINTAIN BLDG WALLS &/OR APPURTENANCES. NOTED: AT PARAPET,FACADE W/STEP CRACKS & SPALLING MASONRY ALONG NELSON AVE & ALONG 108 STREET SIDES. REMEDY: COMPLY W/CODE.
#35234686N
Jun 8, 2018
IN VIOLATION
$0
Mar 16, 2017Construction CLASS - 2
EXIT DOOR NOT SELF CLOSING. NOTED: FPSC DOOR NOT SELF CLOSING AT KG-3 HALL,AT RM 2 HALL. REMEDY: COMPLY W/CODE.
#35234685L
Apr 13, 2018
IN VIOLATION
$0
DOB (11)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#07774
DOB VIOLATION - ACTIVE
Oct 30, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00061
DOB VIOLATION - ACTIVE
Aug 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00373
DOB VIOLATION - ACTIVE
Jun 18, 2021CONSTRUCTION
FTM EXTERIOR FACADE AND APPURTENANCES. EXP 1 WEST ELEVATION OBSERVED HORIZONTAL CRACKING ON THIRD FLOOR, BROKEN WINDOW SILL ON SECOND FLOOR EXPOSURE 2 NORTH ELEVATION. OBSERVED VERTICAL CRACKING IN PARAPET, STEP CRACKING IN CHIMNEY. REMEDY: MAINTAIN EXTERIOR BUILDING AND APPURTENANCES
#LLFA01KA
DOB VIOLATION - ACTIVE
Jun 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00596
DOB VIOLATION - ACTIVE
Apr 5, 2019ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST
#01598
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#04244
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#05792
DOB VIOLATION - ACTIVE
Jun 9, 1994LOCAL LAW 62/91 - BOILERS

#02907
DOB VIOLATION - ACTIVE
Jun 9, 1994LOCAL LAW 62/91 - BOILERS

#02910
DOB VIOLATION - ACTIVE
Jun 9, 1994LOCAL LAW 62/91 - BOILERS

#02908
DOB VIOLATION - ACTIVE
DOB NOW Safety (20)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Oct 30, 2024AEUHAZ FTC-AEU-HAZ
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Report
Active
Aug 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 5, 2019Elevators EVCAT1
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
Jun 9, 1994Boiler LL6291
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Oct 1, 2026ECBUnknown: ELECTRICAL WORK DOES NOT CONFORM TO APPROVED SUBMITTAL DOCUMENTS/AMENDMENTS. OBSERVED ON 2ND, 3RD FL ELECTRICAL CLOSET NEW 12 / 24 PANELS INSTALLED WITH NEW OVERCURRENT PROTECTION. PERMIT # X01442199 DOES NOT COpen
Oct 1, 2026ECBUnknown: FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. OBSERVED IN ELECTRICAL PANELS FOR THE 2ND, 3RD FL'S NO ARC FAULT PROTECTION FOR NEW A/C LINES FOR ALL CLIENTS ROOMS. ARC FAUOpen