6 floors · 36 apartments · 25,818 sq ft · built 1925 · class D1 · owner of record: Gpg Pierrepont, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 25,818 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 312 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1164 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-04 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 5, 2026 | CONSTRUCTION OPEN FLOOR MISSING WOOD BEAMS GOING FROM 3RD FLOOR TO 4TH FLOOR. DUE TO FIRE #26-00036 | DOB VIOLATION - ACTIVE |
| Jan 5, 2026 | CONSTRUCTION STRUCTURE RENDERED NON-COMPLIANT. DUE TO A FIRE THAT OCCURRED AT APT3B NOTED AT TIME OF INSPECTION SMOKE AND WATER DAMAGE WITH WINDOWS BLOWN OUT AT APARTMENTS 4B,3B,2B,2A,1 B #26-00035 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 8, 2026 | Structurally Compromised Buildings FTF-SC-INITL Report due for structurally compromised property | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 10, 2026 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS 4A, VACATE ORDER #260365 IN THE ENTIRE APARTMENT LOCATED AT APT, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | — |
| Feb 10, 2026 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS 3B, VACATE ORDER #260365 IN THE ENTIRE APARTMENT LOCATED AT APT, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH | — |
| Sep 15, 2026 | B | Apt 4B · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES. IN THE FOYER LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Oct 20, 2026 |
| Aug 26, 2026 | C | Apt 1B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 3rd APARTMENT FROM EAST AT SOUTH | Sep 1, 2026 |
| Aug 26, 2026 | A | Apt 1B · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 3rd APARTMENT FROM EAST AT SOUTH | Nov 29, 2026 |
| Jul 27, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT EAST WALL AT BULKHEAD TO THE ROOF AT PUBLIC HALL | Aug 31, 2026 |
| Feb 4, 2026 | C | Apt 5D · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Feb 18, 2026 |
| Feb 4, 2026 | C | Apt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANES AT UPPER AND LOWER SASHES WINDOW AT WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Feb 10, 2026 |
| Feb 4, 2026 | C | Apt 3B · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH | Feb 10, 2026 |
| Feb 3, 2026 | C | Apt 4C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 1, 2026 |
| Feb 2, 2026 | C | Apt 1F · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 1, 2026 |
| Mar 2, 2020 | C | Apt 1B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPRX. 20 SQ. FEET , SOUTH WALL APPRX. 10 SQ. FEET AND EAST WALL APPRX. 10 SQ. FEET IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST | Mar 23, 2020 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 15, 2026 | HPD B | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES. IN THE FOYER LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Aug 26, 2026 | HPD C | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Aug 26, 2026 | HPD A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 27, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT EAST WALL AT BULKHEAD TO THE ROOF AT PUBLIC HALL | Open |
| Jul 8, 2026 | DOB Safety | Structurally Compromised Buildings: Report due for structurally compromised property | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 6:35 PM ET. BBL 3002360007.