10,000 sq ft · built 2025 · class O5 · owner of record: 7565 186 Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 69 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 25, 2026 | Unknown CLASS - 2 OBSERVED : EXPOSURE 3 ERECTED SUPPORTED SCAFFOLD AND FOUND IT IINADEQUATE WITH SEVERAL ISSUES LIKE DEBRIS NETTING NOT STRAIGHT , MISSING TOE BOARDS AND OSHA PLANKS NOT TIE UP . STOP ALL USE OF SUPPOTED SCAFFOLD #39550956Y | Jun 23, 2026 DEFAULT | $10,000 |
| Feb 25, 2026 | Unknown CLASS - 2 NOTED INADEQUATE OVER HEAD PROTECTION EXPOSURE 2., AND MISSING ON EXPOSURE 4 . NO DETAIL OF IT ON SSP , . STOP ALL WORK ON EXPOSURE 2,4 AND 10 FEET INWARD PROVIDE OHP AND DETAILS DRAWINGS FOR IT #39550955M | Jun 23, 2026 DEFAULT | $10,000 |
| Nov 7, 2025 | Unknown CLASS - 2 3308.6.2.11 CLEANING: AN ACTIVE 3 STORY BUILDING WITH NO FACADE WORK GOING I OBSERVED HORIZONTAL NETTING AT EXPOSURE #4 THAT HAD PLYWOOD STYROFOAM, CMU AND DEBRIS ON THE HORIZONTAL NETTING HORIZONTAL SAFETY NET #39546765J | Jul 20, 2026 DEFAULT | $5,000 |
| Aug 8, 2025 | Unknown CLASS - 2 TIME OF INSPECTION ALL FIRE EXTINGUISHERS FOUND TO BE EXPIRED #39543443N | Mar 23, 2027 | $5,000 |
| Aug 8, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION GUARDRAILS MISSING 4 WORKERS WORKING AROUND IT ITS AT LEAST 10 FOOT DROP PROVIDE GUARDRAILS #39543444P | Mar 23, 2027 | $5,000 |
| Aug 8, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION, FOUR WORKERS WERE OBSERVED CONSTRUCTING A CMU WALL AT EXP 2 ADJACENT TO NEIGHBORING PROPERTY. NO PROTECTION WAS IN PLACE. PROVIDE ADEQUATE PROTECTION. THIS CONDITION POSES A HAZARD TO NEX #39543442L | Mar 23, 2027 | $5,000 |
| Aug 8, 2025 | Unknown CLASS - 2 WORKERS WERE OBSERVED ON THE SCAFFOLD WITHOUT PROPER FALL PROTECTION; THOSE WHO WERE TIED OFF WERE IMPROPERLY ANCHORED TO REBAR. AS PER THE APPROVED PLANS, 3-INCH SLEEVE ANCHORS MUST BE USED AND CONNECTED TO D- #39543441J | Mar 23, 2027 | $5,000 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 18, 2026 | DOB | CONSTRUCTION: BORO COMMISSIONER HAS ORDERED WORK STOPPED FOR # Q00850905-S3 DUE TO SUPERINTENDENT OF CONSTRUCTION/SITE SAFETY WITHDRAWAL. | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)