Queens · Block 2265 · Lot 103 · 11375

75-42 Grand Central Pkwy

6 floors · 10 apartments · 11,726 sq ft · built 2019 · class C1 · owner of record: Gc 42 Llc

0open violations
$64,059ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found

Open violations

ECB / OATH (23) · $64,059 owed
IssuedViolationHearingBalance
Aug 30, 2023Construction CLASS - 2
I OBSERVED PEDESTRIAN PROTECTION(SIDE WALK SHED) WITH PIPE SCAFFOLD INSTALLED ON TOP MAINTAINED CONTRARY TO CODE. I OBSERVED DIRT AND DEBRIS COVERED SIDEWALK SHED FOOTINGS AS WELL AS DETERIORATING/ROTTED SIDEWA
#39521193M
Dec 1, 2025
IN VIOLATION
$2,400
Aug 30, 2023Construction CLASS - 2
I OBSERVED 5 WORKERS ON SITE A SIDEWALK SHED INSTALLED AT EXPOSURE 1 AND SCAFFOLD INSTALLED AT EXPOS 1&3 (EXPO 1 ON TOP OF SHED) UPON REQUEST TO SEE THE FOLLOWING DOCUMENTS TO BE KEPT ON SITE NONE WERE PROVIDED
#39521191Z
Dec 1, 2025
IN VIOLATION
$625
Aug 30, 2023Construction CLASS - 2
UPON INSPECTION OF AN ACTIVE 6 STORY NB I OBSERVED WORK NOT CONTRARY TO THE SUBMITTED SITE SAFETY PLAN. CONTRARY TO SSP NO ROOF PROTECTION WAS PROVIDED FOR 1 STORY NEIGHBORING GAR AT REAR OF EXPOSURE 2 ALONG WI
#39521192K
Dec 1, 2025
IN VIOLATION
$509
Aug 30, 2023Construction CLASS - 2
I OBSERVED A SIDE WALK SHED INSTALLED CONTRARY TO CODE. SIDEWALK SHED DID NOT COVER FULL WIDTH OF SIDEWALK AND SHED LEG POST LANDED BEYOND THE 18" MIN FROM CURB LINE AS PER CODE BC3307.6.3 AT APPROX. 62". AS WE
#39521187X
Apr 16, 2024
IN VIOLATION
$2,400
Apr 27, 2023Site Safety CLASS - 1
AT TIME OF INSPECTION OF NB 6 STORY BUILDING ACTIVE JOBSITE OBSERVED SWS INSTALLED AT EXP1, SF INSTALLED AT EXP1,3, PLATFORMS AT ELEVATOR SHAFTS, PULLEY INSTALLED AT BULKHEAD, UPON REQUEST FROM CS TO SEE THE DA
#39515904Z
Aug 1, 2023
IN VIOLATION
$2,500
Mar 24, 2023Construction CLASS - 1
VIOLATION # 39508590J UNDER COMPLAINT # 4906449 FOR INADEQUATEUNSAFE VERTICAL NETTING AT 6TH FL, MISSING TOE-BOARDS ON MULTIPLE FLOORS WAS NOT CORRECTED OR CERTIFICATE OF CORRECTION FILLED. THE ECB VIOLATION WA
#39514760Y
Oct 24, 2023
IN VIOLATION
$2,500
Mar 24, 2023Construction CLASS - 1
UNSAFE JOB SITE WITH PSWO IN PLACE. INADEQUATE GUARD RAIL SYSTEM, NETTING AND HOUSEKEEPING.
#39514609L
May 30, 2023
IN VIOLATION
$2,500
Mar 24, 2023Construction CLASS - 1
VIOLATION # 39508576N UNDER COMPLAINT # 4906445 WAS ISSUED ON 11/01/2022 FOR NO DESIGN DRAWINGS FOR PLATFORM. JOB SITE NOT IN COMPLIANCE, NO DRAWINGS AND NO CERTIFICATE OF CORRECTION. THE ECB VIOLATION WAS RE-W
#39514759R
Oct 24, 2023
IN VIOLATION
$1,250
Mar 24, 2023Construction CLASS - 1
VIOLATION # 39508574J WAS ISSUED FOR UNSAFE SUPPORTED SCAFFOLD, AND IT IS NOT IN COMPLIANCE WITHOUT CERTIFICATE OF CORRECTION FILLED AND SCAFFOLD NOT REPAIRED. THE ECB VIOLATION WAS RE-WRITTEN.
#39514742K
Oct 24, 2023
IN VIOLATION
$1,250
Jan 13, 2023Construction CLASS - 2
AT TIME OF INSPECTION FOR A 6 STORY NEW BUILDING I OBSERVED NO COMPLIANCE FROM RESPONDENT IN REGARD TO PREVIOUSLY ISSUED VIOLATION 39508574J ISSUED ON 11-1-22 NO CERTIFICATE OF CORRECTION WAS SUBMITTED TO THE D
#39511633H
Sep 12, 2023
IN VIOLATION
$1,250
Jan 13, 2023Construction CLASS - 2
AT TIME OF INSPECTION FOR A 6 STORY NEW BUILDING I OBSERVED NO COMPLIANCE FROM RESPONDENT IN REGARD TO PREVIOUSLY ISSUED VIOLATION 39508590J ISSUED ON 11-1-22 NO CERTIFICATE OF CORRECTION WAS SUBMITTED TO THE D
#39511635L
Sep 12, 2023
IN VIOLATION
$1,250
Jan 13, 2023Construction CLASS - 2
AT TIME OF INSPECTION FOR A 6 STORY NEW BUILDING I OBSERVED NO COMPLIANCE FROM RESPONDENT IN REGARD TO PREVIOUSLY ISSUED VIOLATION 39508576N ISSUED ON 11-1-22 NO CERTIFICATE OF CORRECTION WAS SUBMITTED TO THE
#39511634J
Sep 12, 2023
IN VIOLATION
$1,250
Nov 1, 2022Construction CLASS - 1
OBSERVED 6TH FLR VERTICAL NETTING CABLES AT THE INTERIOR STAIR OPENING LEADING EDGE AND THE EXP#1,3 LEADING EDGES WERE ONLY APPROX. 30-35" HIGH, THE CABLES WERE SEVERELY LOOSENED, AND AT LEAST ONE POST WAS SEVE
#39508590J
Dec 20, 2022
DEFAULT
$12,500
Nov 1, 2022Construction CLASS - 2
OBSERVED SIDEWALK SHED (SWS) AT EXP#1 AND SUPPORTED SCAFFOLDS AT EXP#1,3- NO APPROVED DESIGN DRAWINGS FOR THE SUPP SCAFF + SWS, ALONG WITH THE SWS DAILY INSPECTION LOG AND SUPP SCAFF PRE-SHIFT LOG WERE PROVIDED
#39508575L
Dec 20, 2022
DEFAULT
$3,125
Nov 1, 2022Construction CLASS - 1
OBSERVED TEMPORARY PLATFORMS IN ELEVATOR SHAFT AT ALL FLOORS- BUILT CONTRARY TO PE-APPROVED DD- NO WOOD LEDGER, WOOD PLANKS/JOIST NOT EXTENDED 8'-1/4" PAST SHAFT OPENING, SOME PLANKS/JOISTS PLACED DIAGONALLY. A
#39508576N
Dec 20, 2022
DEFAULT
$6,250
Nov 1, 2022Construction CLASS - 1
OBSERVED SUPPORTED SCAFFOLD AT EXP#1,3 WITH THE FOLLOWING CONDITIONS: MISSING GUARD RAILS/TOE-BOARDS ON WORKING PLATFORMS; MISSING PINS ON OUTRIGGERS; LOOSE AND DISLODGED PLANKS; LOOSE NETTING; DAMAGED AND BENT
#39508574J
Dec 20, 2022
DEFAULT
$6,250
Jul 6, 2022Unknown CLASS - 2
OBSERVED INADEQUATE LOGS NO ACTUAL ORIENTATIONS FOR ALL WORKERS, SUPERINTENDENT TIME IN/OUT, PRE SHIFT MEETING, AND TOOLS BOX. 5 WORKERS ON 3RD FL DECK WORKING ON CMU, VENEER BLOCKS ON EDGE WITHOUT FALL ARREST
#39503133L
Aug 23, 2022
DEFAULT
$5,000
Jul 6, 2022Construction CLASS - 1
AT THE TIME OF INSPECTION 6 STORIES NEW BUILDING ABOUT 7 WORKERS I REQUEST SITE SAFETY ORIENTATIONS TO BE PROVIDED ON SITE THE COMPETENT PERSON PROVIDE PIECE OF PAPER HAS SIGNING ALL WORKERS WITHOUT ANY SUBJECT
#39503142N
Jan 24, 2023
IN VIOLATION
$625
Mar 5, 2020Construction CLASS - 2
HOUSEKEEPING.AT THE TIME OF INSPECTION OF AN ACTIVE 6 STORY BUILDING CONSTRUCTION SITE I OBSERVED OF CONSTRUCTION MATERIALS.DEBRIS SCATTEREDALL OVER THE SITE.MATERIALS,DEBRIS,TOOLS LAYING ON FLOORS BLOCKING EGR
#35466973Z
Aug 3, 2021
IN VIOLATION
$1,250
Jan 30, 2020Construction CLASS - 2
BC3301.7/FAILURE TO PROVIDE PRE APPROVED DETAIL DRAWINGS.AS NOTED AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,FLOOR #4 METAL DECK PLACEMEN WORK.OBSERVED EXPOSURE #2,#4 STAIRWELL STEEL PANEL STAIRCASE AN
#35445062P
Jun 1, 2021
IN VIOLATION
$1,250
Jan 30, 2020Construction CLASS - 2
FAILURE TO SAFEGUARD ALL PERSONS OR PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AS NOTED:AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION SITE METAL DECK WORK ON THE FLOOR #4.OBSERVE AT EXPOSURE#2,FRONT AND REA
#35445061N
Jun 1, 2021
IN VIOLATION
$5,000
Dec 12, 2019Construction CLASS - 1
3307.2.1 OBSTRUCTION OF STREET OR SIDEWALK @THE TIME OF INSPECTION @4STY NB I OBSERVED MATERIALS TIED TOGETHER WITH CAUTION TAPE IN THE STREET @EXP1.THESE LARGE MATERIALS WERE OBSTRUCTING THE STREET & COULD BE
#35462689N
Mar 23, 2021
IN VIOLATION
$625
Dec 12, 2019Construction CLASS - 1
3307.7.7 CONDITION OF FENCE @THE TIME OF INSPECTION @A 4STY NB I OBSERVED A POORLY MAINTAINED CONST FENCE. PANELS FROM THE FENCE HAD FALLEN OFF INTO THE GARDEN OF THE ADJOINING PROPERTY, THERE WAS PROTECTING
#35462688L
Mar 23, 2021
IN VIOLATION
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:27 PM ET. BBL 4022650103.