Brooklyn · Block 526 · Lot 23 · 11231

74 Nelson Street

4 floors · 8 apartments · 5,100 sq ft · built 1931 · class C1 · owner of record: Filakouris Realty Llc

136open violations
$0ECB/OATH penalties owed
23HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 68 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-04 (Accepted). Agency page

Dec 31, 2026
in 68 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
Jan 4, 2012Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS. STUCCO APPLIED TO BRICK FACADE IS CRACKED & SPALLING AT 3RD & 4TH FLOORS ON EXPOSER #1 AS ALSO NOTED IN PREVIOUS ECB NOV #34930229K ISSUED 11-4-11. REM:OBTAIN ALL NE
#34779748N
Mar 19, 2012
IN VIOLATION
$0
Dec 7, 2011Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED FROM STREET,FRONT BRICK FACADE IS DEFECTIVE W/SECTIONS OF BRICK FACE & MORTAR AT 3RD & 4TH FLOOR LEVELS SPALLING WELL AS C
#34930363L
Jan 23, 2012
WRITTEN OFF
$0
Nov 4, 2011Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG WALL.STUCCO APPLIED TO BRICK FACADE IS CRACKED & SPALLING AT 3RD & 4TH FLRS ON EXP.#1.REMEDY:MAINTAIN BLDG WALL.OBTAIN ALL NECESSARY PERMITS.
#34930229K
Jan 23, 2012
WRITTEN OFF
$0
Jan 27, 1993Construction Hazardous
FAILURE TO MAINTAIN: HALLAWAY WALL AT 3RD FLR HAVE HEAVY WATER DAMAGE PLASTER AT SAID AREA BEGIN TO DETERIORATE.ALSO 4TH FLR APARTMENT NUM-BER EIGHT HAVE EXCESIVE WATER DAMAGE TO CEILING, PLASTER COMMING DOWN.
#34075690Y
Apr 12, 1993
WRITTEN OFF
$0
DOB (17)
IssuedViolationStatus
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#10312
DOB VIOLATION - ACTIVE
Apr 4, 2012FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00126
DOB VIOLATION - ACTIVE
Mar 7, 2012FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00145
DOB VIOLATION - ACTIVE
Jan 25, 2012FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00317
DOB VIOLATION - ACTIVE
Dec 7, 2011CONSTRUCTION

#0601TS
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#19872
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#20879
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#12761
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#13496
DOB VIOLATION - ACTIVE
Mar 16, 1999LOCAL LAW 62/91 - BOILERS

#13254
DOB VIOLATION - ACTIVE
May 23, 1997CONSTRUCTION

#06HS02
DOB VIOLATION - ACTIVE
Oct 23, 1996CONSTRUCTION

#06H01
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#37627
DOB VIOLATION - ACTIVE
Oct 24, 1994CONSTRUCTION

#6C02
VIOLATION WORK W/OUT PMT HAZARDOUS - ACTIVE
Jun 1, 1994LOCAL LAW 62/91 - BOILERS

#27385
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#37885
DOB VIOLATION - ACTIVE
Jun 1, 1993LOCAL LAW 62/91 - BOILERS

#27384
DOB VIOLATION - ACTIVE
DOB NOW Safety (12)
IssuedViolationStatus
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Apr 4, 2012AEUHAZ FTC-AEU-HAZ
Active
Mar 7, 2012AEUHAZ FTC-AEU-HAZ
Active
Jan 25, 2012AEUHAZ FTC-AEU-HAZ
Active
Jan 6, 2006Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Feb 7, 2000Boiler LL6291
Active
Mar 16, 1999Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
Jun 1, 1994Boiler LL6291
Active
Jun 1, 1993Boiler LL6291
Active
HPD (103) · C 23 · B 53 · A 27
IssuedClassViolationCorrect by
Oct 12, 2021BApt 8 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 16, 2021
Oct 12, 2021BApt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 16, 2021
Oct 12, 2021BApt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 16, 2021
Oct 12, 2021AApt 8 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND WASHTUB IN THE BATHROOM LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJan 15, 2022
Oct 12, 2021CApt 8 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 7, 2021
Nov 7, 2011C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING TWO METAL TREADS AT 2ND STY FIRE ESCAPE SOUTH STACK YARDNov 13, 2011
Nov 7, 2011CApt 1 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES GAS STOVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORYNov 13, 2011
Nov 7, 2011CApt 1 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOISTURE PENETRATING AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1, 1st STORYNov 13, 2011
Nov 7, 2011C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMNov 13, 2011
Nov 7, 2011C§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT VERTICAL CRACK ON REAR BRICK WALL SOUTH/EAST CORNER FROM 2STY TO PARAPET WALL YARDNov 13, 2011
Apr 5, 2010A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYJul 9, 2010
Jun 4, 2008A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.Sep 7, 2008
Jun 4, 2008B§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB VESTIBULE TO 1 STY PUBLIC HALL.Jul 9, 2008
Jun 4, 2008B§ 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING CELLAR THRU OUT.Jul 9, 2008
Jun 4, 2008B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES CEILING LIGHT FIXTURE NEAR SOUTH & FRONT NORTHWEST CELLAR.Jul 9, 2008
Jun 4, 2008B§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BOILER ROOM CELLAR.Jul 9, 2008
Jun 4, 2008B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER WALLS & CEILING 3 STY PUBLIC HALL.Jul 9, 2008
Jun 4, 2008A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING 3 TO 4 STY PUBLIC HALL.Sep 7, 2008
Jun 4, 2008B§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL 3 TO 4 STY PUBLIC HALL STAIRWELL.Jul 9, 2008
Jun 4, 2008BApt 4 · § 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Jul 9, 2008
Jun 4, 2008BApt 4 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS LOWER SASH REAR SOUTHWEST ROOM EAST WINDOW 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Jul 9, 2008
Jun 4, 2008BApt 4 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS LOWER SASH REAR SOUTHWEST ROOM WEST WINDOW 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Jul 9, 2008
Jun 4, 2008BApt 4 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD SASHES WINDOW REAR SOUTH ROOM 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Jul 9, 2008
Jun 4, 2008BApt 4 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES CEILING LIGHT FIXTURE KITCHEN & REAR SOUTH ROOM 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Jul 9, 2008
Jun 4, 2008AApt 4 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS THRU OUT 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Sep 7, 2008
Jun 4, 2008BApt 4 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE REAR SOUTHEAST ROOM 2 STY REAR SOUTH APT 4. LOCATED AT APT 4Jul 9, 2008
Jun 4, 2008C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED.Jun 10, 2008
Jun 4, 2008A§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES VESTIBULE 1 STY PUBLIC HALL.Sep 7, 2008
Jun 4, 2008A§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR 3 STY PUBLIC HALL.Sep 7, 2008
Jun 4, 2008A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE ALL STYS PUBLIC HALL.Sep 7, 2008
Jun 4, 2008C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED.Jun 10, 2008
Jun 4, 2008B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE METAL NOSING STAIRS 3 TO 4 STY PUBLIC HALL LANDING.Jul 9, 2008
Jun 4, 2008BD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION CEILING 3 STY PUBLIC HALL NIGHT INSPECTION.Jul 9, 2008
Jun 4, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK VESTIBULE DOOR TO 1 STY PUBLIC HALL.Jul 9, 2008
Jun 4, 2008AD26-10.01 ADM CODE PROVIDE SLIDE BOLT HOOK & EYE OR LOCK WHICH DOES NOT REQUIRE A KEY TO OPEN SCUTTLE COVER TO ROOF.Sep 7, 2008
Jun 4, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR.Jun 10, 2008
Jun 4, 2008B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MATTRESSES REAR SOUTH CELLAR.Jul 9, 2008
May 3, 2006BApt 8 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006CApt 8 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS WINDOW PANE AND WINDOW SASH/FRAME IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMay 14, 2006
May 3, 2006BApt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006CApt 8 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMay 14, 2006
May 3, 2006AApt 8 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , NORTH WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL, 1st DOOR FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 11, 2006
May 3, 2006BApt 8 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR FRAME IN THE BATHROOM LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006BApt 8 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD DOOR AND MORTICE LOCK IN THE BATHROOM LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006AApt 8 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 11, 2006
May 3, 2006BApt 8 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR IN THE KITCHEN LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006BApt 8 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR MORTICE LOCK IN THE KITCHEN LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006AApt 8 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , CEILING, 1st WINDOW FRAME FROM SOUTH AT WEST WALL, 2nd WINDOW FRAME FROM SOUTH AT WEST WALL, EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 11, 2006
May 3, 2006BApt 8 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CLOSET DOOR LOCK IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006BApt 8 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 12, 2006
May 3, 2006AApt 8 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , SOUTH WALL, 1st CLOSET FROM NORTH AT EAST WALL DOOR FRAME IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 11, 2006
May 3, 2006AApt 8 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL, NORTH WALL, 2nd WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROMAug 11, 2006
May 3, 2006CApt 8 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APTMay 29, 2006
May 3, 2006CApt 8 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APTMay 29, 2006
May 3, 2006CApt 8 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 8, 4th STORY, 1st APARTMEMay 29, 2006
May 3, 2006CApt 8 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE KITCHEN LOCATED AT APT 8, 4th STORY, 1st APARTMENT FROM EAST AT SOUTMay 29, 2006
Sep 22, 2005A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT PUBLIC HALL, 1st STORYDec 31, 2005
Sep 22, 2005A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYDec 31, 2005
Sep 22, 2005C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAILBOXES AT PUBLIC HALL, 1st STORYOct 3, 2005
Sep 22, 2005AApt 8 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 8, 4th STORY, APARTMENT AT SOUTHDec 31, 2005

Showing 60 of 103. Full list on the agency site.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 9:03 AM ET. BBL 3005260023.