2 floors · 2 apartments · 3,920 sq ft · built 1928 · class S9 · owner of record: D'Alessandro Robert
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-07-24 (Accepted). Agency page | Dec 31, 2026 in 70 days | 1 of 1 without an accepted 2026 report yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 801 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 27, 2015 | Quality of Life CLASS - 2 RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLIG FOR MORE THAN THE LEGALLYAPPROVED NUMBER OF FAMILIES. NOTED:A LEGAL 2 FAMILY MIXED USE BUILDINGHAS BEEN CONVERTED TO A 3 FAMILY MIXED USE BUILDING WITH THE ADDITION #35137204R | Sep 15, 2015 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #18187 | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #23640 | DOB VIOLATION - ACTIVE |
| Jan 6, 2006 | LOCAL LAW 62/91 - BOILERS #23064 | DOB VIOLATION - ACTIVE |
| Jun 7, 1994 | LOCAL LAW 62/91 - BOILERS #05068 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Jan 3, 2008 | Boiler LL6291 | Active |
| Jan 6, 2006 | Boiler LL6291 | Active |
| Jun 7, 1994 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 7, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 10, 2026 |
| Jun 12, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 15, 2025 |
| Apr 15, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 19, 2024 |
| Mar 29, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 2, 2023 |
| Mar 25, 2013 | A | Apt 2R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE KITCHEN , THE 1st ROOM FROM NORTH AT EAST, THE 1st ROOM FROM NORTH AT WEST, THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH | Jun 28, 2013 |
| Mar 25, 2013 | B | Apt 2R · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 29, 2013 |
| Mar 25, 2013 | B | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPX. 2 SQ FT AT WINDOW FRAME IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 29, 2013 |
| Mar 25, 2013 | A | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPX. 4 SQ FT AT 1ST AND 2ND WINDOW FRAME FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2013 |
| Mar 25, 2013 | A | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPX. 2 SQ FT AT WINDOW FRAME IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2013 |
| Mar 25, 2013 | A | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPX. 2 SQ FT AT WINDOW FRAME IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2013 |
| Mar 25, 2013 | C | Apt 2R · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WES | Apr 15, 2013 |
| Mar 25, 2013 | A | Apt 2R · § 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO HEAVY-DUTY DEAD BOLT AND LATCHSET LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2013 |
| Mar 25, 2013 | A | Apt 2R · § 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2013 |
| Mar 25, 2013 | B | Apt 2R · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR TENANT: LEON NAZLY. LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 29, 2013 |
| Jan 7, 2013 | B | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AROUND WINDOWS FRAME APPROX 4 SQ, FT. IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2R, 2nd STORY | Feb 11, 2013 |
| Jan 7, 2013 | B | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AROUND WINDOWS FRAME APPROX 4 SQ. FT. IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2R, 2nd STORY | Feb 11, 2013 |
| Jan 7, 2013 | B | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AROUND WINDOW FRAME APPROX 4 SQ. FT, IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY | Feb 11, 2013 |
| Jan 7, 2013 | B | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AROUND WINDOWS FRAME APPROX 4 SQ. FT. ( TWO WINDOWS ) IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY | Feb 11, 2013 |
| Jan 7, 2013 | B | Apt 2R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AROUND WINDOW FRAMES APPROX4 SQ. FT. IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2R, 2nd STORY | Feb 11, 2013 |
| Aug 14, 2008 | C | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING SCUTTLE LADDER 2 STY PUT HALL TO ROOF. | Aug 20, 2008 |
| Aug 14, 2008 | C | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED AT ENTRANCE DOOR TO BLDG. | Aug 20, 2008 |
| Aug 21, 2007 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED. | Aug 27, 2007 |