Queens · Block 1274 · Lot 1 · 11372

74-10 35 Avenue

6 floors · 210 apartments · 147,000 sq ft · built 1954 · class D3 · owner of record: Jackson Surrey 35th Llc

140open violations
$2,500ECB/OATH penalties owed
26HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-15 (Accepted). Agency page

Dec 31, 2026
in 64 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 147,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1274). Agency page

Dec 31, 2034
in 2986 days
Next due 2034

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Oct 1, 2024Construction CLASS - 1
FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#Q0000951 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS
#37030034X
Mar 4, 2025
IN VIOLATION
$2,500
DOB (0)

None open.

DOB NOW Safety (14)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
HPD (126) · C 26 · B 81 · A 19
IssuedClassViolationCorrect by
Aug 25, 2026BApt 507E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT EAST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 507E, 5th STORY, 1st APARTMENT FROM NORTH AT EASTSep 29, 2026
Jul 23, 2026BApt 401W · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE BATH TUB IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''Aug 27, 2026
Jul 23, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOORAug 6, 2026
Jul 23, 2026AApt 401W · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN SQ FT FT AT WINDOW RECESS AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''Oct 26, 2026
Jul 23, 2026BApt 401W · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''Aug 27, 2026
Jun 15, 2026BApt 615W · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 615W, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 20, 2026
Jun 15, 2026BApt 615W · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 615W, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 20, 2026
Jun 15, 2026CApt 615W · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 615W, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 11, 2026
Jun 15, 2026BApt 615W · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 615W, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 20, 2026
Jun 15, 2026AApt 615W · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 615W, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 18, 2026
Mar 3, 2026CApt 401W · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMar 9, 2026
Mar 3, 2026BApt 401W · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ FT AT NORTH WALL IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHApr 7, 2026
Mar 3, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT VESTIBULE AT PUBLIC HALL, 1st STORYJun 6, 2026
Mar 3, 2026AApt 401W · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 6, 2026
Mar 3, 2026AApt 401W · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 6, 2026
Jan 12, 2026BApt 401W · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR AT UPPER CABINET IN THE KITCHEN LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WESTFeb 16, 2026
Jan 12, 2026BApt 401W · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WESTFeb 16, 2026
Jan 12, 2026CApt 401W · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUBFLOOR IN THE KITCHEN LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WESTJan 18, 2026
Jan 12, 2026BApt 401W · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WESTFeb 16, 2026
Jan 12, 2026BApt 401W · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WESTFeb 16, 2026
Jan 6, 2026CApt 607E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Feb 1, 2026
Dec 19, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT BASEMENT AT BOILER ROOMDec 25, 2025
Dec 18, 2025CApt 607E · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Dec 18, 2025
Sep 15, 2025BApt APT618 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT APT618, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SOct 20, 2025
Sep 15, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES HOPPER INSIDE COMPACTOR CLOSET AT PUBLIC HALL, 1st STORY, SECTION AT WESTSep 29, 2025
Sep 15, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH COMPACTOR CLOSET AT PUBLIC HALL, 1st STORY, SECTION AT WESTSep 29, 2025
Sep 15, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH 1ST STAIRWAY FROM SOUTH AT WEST LABELLED 1C AT PUBLIC HALL, 1st STORY, SECTION AT WESTSep 29, 2025
Sep 15, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH ASSEMBLY ON 1ST STAIRWAY DOOR FROM SOUTH AT WEST LABELLED 5C AT PUBLIC HALL, 5th STORY, SECTION AT WESTOct 20, 2025
Sep 15, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH COMPACTOR CLOSET AT PUBLIC HALL, 1st STORY, SECTION AT EASTSep 29, 2025
Sep 15, 2025BApt APT618 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT APT618, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST ,Oct 20, 2025
Sep 15, 2025BApt APT618 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT APT618, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOct 20, 2025
Sep 15, 2025BApt APT618 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE FOYER LOCATED AT APT APT618, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOct 20, 2025
Sep 15, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SSEMBLY ON 1ST STAIRWAY DOOR FROM NORTH AT EAST LABELLED 1B AT PUBLIC HALL, 1st STORY, SECTION AT EASTOct 20, 2025
Sep 15, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH 1ST STAIRWAY FROM NORTH AT EAST LABELLED 1B AT PUBLIC HALL, 1st STORY, SECTION AT EASTSep 29, 2025
Sep 15, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH ASSEMBLY COMPACTOR CLOSET DOOR AT PUBLIC HALL, 1st STORY, SECTION AT EASTOct 20, 2025
Sep 15, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH ASSEMBLY ON 1ST STAIRWAY DOOR FROM SOUTH AT WEST LABELLED 1C AT PUBLIC HALL, 1st STORY, SECTION AT WESTOct 20, 2025
Sep 15, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH ASSEMBLY COMPACTOR CLOSET DOOR AT PUBLIC HALL, 1st STORY, SECTION AT WESTOct 20, 2025
Jun 27, 2025BApt 504WES · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT EAST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 504WES, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17720343 ISSUED 25-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIAug 1, 2025
May 13, 2025BApt 306E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, AND EAST WALL IN THE BATHROOM LOCATED AT APT 306E, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2025
May 13, 2025BApt 306E · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 306E, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2025
May 13, 2025BApt 306E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILLING IN THE BATHROOM LOCATED AT APT 306E, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2025
May 13, 2025BApt 306E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 306E, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2025
May 8, 2025B§ 27-2005 ADM CODE PROVIDE SECURITY IN AN EVENT OF A POWER OUTTAGE BY MEANS OF A HEAVY DUTY LOCK AND LATCH SET AT VESTIBULE DOOR TO PUBLIC HALL , 1st STORYJun 12, 2025
May 8, 2025C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE AT VESTIBULE DOOR TO PUBLIC HALL , 1st STORYMay 14, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE FOYER LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Mar 13, 2025B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTUDING BEYOND THE WINDOW SILL AT NORTH STACK BUILDING FRONT AT FIRE ESCAPE, 4th STORYApr 17, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 5th ROOM FROM NORTH LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Mar 13, 2025BApt 607E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''Apr 17, 2025
Feb 26, 2025BApt 504WES · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WINDOW RECESS AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 504WES, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTApr 2, 2025
Feb 26, 2025BApt 504WES · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WINDOW RECESS AT EAST WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 504WES, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTApr 2, 2025
Feb 26, 2025BApt 504WES · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 504WES, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTApr 2, 2025
Feb 26, 2025AApt 504WES · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 504WES, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTJun 1, 2025
Feb 13, 2025BApt 607E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 607E, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT EAST ORIGINAL VIOLATION 17345610 ISSUED 14-OCT-24 HAS BEEN UPGRADEMar 20, 2025
Jan 27, 2025CApt 619W · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 619W, 6th STORY, 5th APARTMENT FROM NORTH AT EAST , SECTION AT WESTFeb 22, 2025
Jan 27, 2025CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT COMPACTOR CLOSET, 6th STORY, SECTION AT WESTFeb 22, 2025
Jan 27, 2025CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT LAUNDRY ROOMFeb 22, 2025

Showing 60 of 126. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Aug 25, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT EAST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 507E, 5th STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Jul 23, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE BATH TUB IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''Open
Jul 23, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOROpen
Jul 23, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN SQ FT FT AT WINDOW RECESS AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''Open
Jul 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 401W, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 6:18 AM ET. BBL 4012740001.