Bronx · Block 2720 · Lot 28 · 10455

731 Southern Boulevard

8 floors · 48 apartments · 26,400 sq ft · built 2004 · class D1 · owner of record: 731 Southern Llc

15open violations
$45,401ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-09 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 26,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $24,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 483 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029

Open violations

ECB / OATH (12) · $45,401 owed
IssuedViolationHearingBalance
Mar 10, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39103080Y., FILE A CERTIFICATE OF CORRECTION
#39179780X
May 15, 2026
ADMIT/IN-VIO
$0
Dec 1, 2025Elevators CLASS - 2
CLASS 2: ADJUST 1ST FLOOR DOOR FOR SMOOTH OPERATION. EMERGENCY PHONE INOPERATIVE, PROVIDE 2 WAY COMMUNICATION. FLOOR 5 DOWN BUTTON ACKNOLEDGE LIGHT INOPERATIVE, REPAIR.
#39168687H
Dec 17, 2026
DEFAULT
$655
Dec 1, 2025Construction CLASS - 2
OBSERVED ON THE1ST AND 2ND FLOOR SPRINKLER HEADS OBSTRUCTED, THE ROOF VENT TERMINAL NOT PROPERLY SUPPORTED AND FERNCO COUPLING USED ON VENT LINE WHICH IS CONTRARY TO CODE SECTIONS PC 102.3 AND BC 903.3.3, REPAI
#39168720K
Dec 17, 2026
DEFAULT
$1,280
Dec 1, 2025Boilers CLASS - 2
FOUND LOCHINVAR GAS FIRED BOILER MODEL #CWN-360, WITH INCORRECT SAFETY RELIEF VALVE,EXPOSED WIRING, LABEL ON RELIEF VALVE ON HOT WATER STORAGE TANK NOT LEGIBLE., MAINTAIN BOILER; REPLACE RELIEF VALVES TO CORREC
#39168676M
Dec 17, 2026
DEFAULT
$1,280
Dec 1, 2025Construction CLASS - 1
FILED A CERTIFICATE, FORM, APPLICATION ETC., CONTAINING A MATERIAL FALSE STATEMENT(S). UNPERMITTED PLASTIC ACCESS PANELS THROUGHOUT BUILING. VIOLATION #39137265X CERT OF CORRECTIONS FILED ON 04/07/2005., COMPLY
#39168727N
Dec 17, 2026
DEFAULT
$25,000
Feb 3, 2025Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39103082H ISSUED ON 01/09/2024 FOR EXCESSIVE STORAGE IN THE ELECTRICAL ROOM. PHOTOS TAKEN, COMPLY WITH COMMISSIONER'S ORDER; COMPLY W
#39137266H
Mar 2, 2026
DEFAULT
$6,250
Feb 3, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. UNPERMITTED PLASTIC ACCESS PANELS THROUGHOUT BUILING. UTILITY ROOMS HAVE WOOD DOO
#39137265X
Jun 13, 2025
IN VIOLATION
$2,500
Feb 3, 2025Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED UNSAFE STORAGE (BOXES, BROOMS, ELECTRICAL SCOOTER, BUILDING MATERIAL, BUCKETS AND MOPS) UNDERNEATH STAIRCASES. LOCATED ON FIRST FLOOR., MAINTAIN ST
#39137263M
Jun 13, 2025
IN VIOLATION
$1,686
Feb 3, 2025Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB #39103080Y ISSUED ON 01/09/2024 FOR ELECTRICAL WORK WITHOUT A PERMIT. THE VIOLATING CONDITIONS SHALL BE COMPLIED WITH IN A TIMELY ORDE
#39137268L
Jun 13, 2025
IN VIOLATION
$2,500
Feb 3, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED FIRE EMERGENCY EXIT BLOCKED BY SEVERAL GARBAGE BINS. LOCATED ON FIRST FLOOR LEVEL LEADING TO BACK YARD AREA. POTENTIAL FIRE HAZARD., REMOVE OBSTRUCTION
#39137264Y
Jun 13, 2025
IN VIOLATION
$1,250
Feb 3, 2025Unknown CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL ROOM THE STORAGE OF BUILDING MATERIAL, OFFICE MATERIALS AND EQUIPMENT. AS PER THE EC THERE SHALL BE NO STORAGE IN THE ELECTRICAL EQUIPMENT ROOM. PHOTOS TAKEN. THIS IS A FIRE HA
#39137269N
Jun 13, 2025
IN VIOLATION
$3,000
Jan 9, 2024Unknown CLASS - 1
I OBSERVED IN THE CORRIDORS THE IMPROPER INSTALLATION OF EMERGENCY LIGHT FIXTURES WITH EXPOSED, ENERGIZED CONDUCTORS. NO PERMIT ON FILE IN DOB RECORDS COVERS THIS WORK. THIS IS AN IMMEDIATE SHOCK/ FIRE HAZARD.
#39103080Y
May 3, 2024
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#24369
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Sep 3, 2026GHG Emissions - LL97 FTF-EN-LL97321
FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B).
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Dec 18, 2025GHG Emissions - LL97 FTF-EN-LL97321
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 2)
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (3) · C 0 · B 0 · A 3
IssuedClassViolationCorrect by
Jun 3, 2026A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER (SHOE) USING APPROPRIATE NUTS AND BOLTS AT 1ST FROM SOUTH AT EAST EXTERIOR WALL (BUILDING FRONT) AT FIRE ESCAPESep 6, 2026
Jun 3, 2026A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYSep 6, 2026
Jun 3, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYSep 6, 2026

Issued in the last 120 days

DateSourceWhatNow
Sep 3, 2026DOB SafetyGHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B).Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 8:51 AM ET. BBL 2027200028.