4 floors · 9 apartments · 5,603 sq ft · built 1899 · class C1 · owner of record: 73 Columbia Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 60 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 12, 2019 | Site Safety CLASS - 1 COMPETENT PERSON.AT THE TIME OF INSPECTION AT A 3 STORY ALT,I OBSERVEDON A ACTIVE JOB SITE WORKERS WORKING ON MULTIPLE LEVELS WITHOUT DESIGNATED COMPETENT PERSON ON SITE.UPON ARRIVING TO SITE I ASKED WORKERS WA #35468212N | Feb 25, 2021 IN VIOLATION | $10,000 |
| Dec 12, 2019 | Construction CLASS - 2 FAILURE TO APPLY D.O.T PERMIT FOR STREET/SIDEWALK CLOSING.AT THE TIM EOF INSPECTION AT A 5 STORY ALT,I OBSERVE NO D.O.T. PERMIT POSTED CONSTRUCTION PANEL/FENCE EXPO 1.PERMITS HAVE TO BE POSTED BECAUSE OF D.O.T. #35468214R | Feb 25, 2021 IN VIOLATION | $1,250 |
| Dec 12, 2019 | Construction CLASS - 1 WORK DOES NOT CONFORM WITH APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS-SIDEWALK SHED(SWS)NOTE:AT THE TIME OF INSPECTION AT A 5 STORY ALT,I OBSERVED ON GROUND LEVEL SWS WAS NOT BUILT TO APROVED PLANS(NO BR #35468213P | Feb 25, 2021 IN VIOLATION | $2,500 |
| Jun 12, 2019 | Construction CLASS - 1 SEC. 3306.5 FAILURE TO SUBMIT REQUIRED DETAILS OF DEMO. IN RESPONSE TOCOMPLAINT OBSERVED PARTIAL DEMOLITION OF STRUCTURE THROUGH EXP#3. NO SEQUANCE SUBMITTED. PLAN THAT WAS SUBMITTED INADEQUATE & DO NOT REFLECT #35424646X | Mar 1, 2021 IN VIOLATION | $2,500 |
| Jun 12, 2019 | Construction CLASS - 1 NOTIFICATION OF EARTHWORK RUKE 52. AT TIME OF INSPECTION OBSERVED SITECURRENTLY @ EXCAVATION OF EXISTING BLDG MINI EXCAVATOR ON SITE & SITE BELOW GRADE APPROX 5-7 FOOT DEPTH. NO NOTIFICATION SUBMITTED TO DEPT. #35424648J | Mar 1, 2021 IN VIOLATION | $2,500 |
| Jun 12, 2019 | Construction CLASS - 1 FAILURE TO PROVIDE SHORING/BRACING. AT TIME OF INSPECTION OBSERVED EXCAVATION OPERATION BELOW GRADE OF OVER 5FT. OPERATIONS FAILED TO PROVIDE SHEER CUT @ EXP#1. NO SHORING OR BRACING IN PLACE. STOP ALL WORK. #35424647H | Mar 1, 2021 IN VIOLATION | $5,000 |
| Jun 11, 2019 | Construction CLASS - 1 3307.4;WARNING SIGNS PERSONAL BARRIERS WARNING SIGNS,PERSONAL,BORDERS SHALL BE PROVIDED TO PROTETC THE PUBLIC FROM () GENERATED BY CONSTRUCTION OR DEMOLITON ACTIVITY IN OR ADJACENT TO A PUBLIC WAY.NOTE:AT TIME #35437329P | Mar 4, 2021 IN VIOLATION | $2,500 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 26, 2022 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | May 1, 2022 |
| Jan 26, 2022 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSED ON WALL AT PUBLIC HALL, 1st STORY | May 1, 2022 |
| Feb 18, 2021 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT 1ST AND 4TH STORIES AT PUBLIC HALL | Mar 25, 2021 |
| Feb 18, 2021 | C | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS BUILDING ENTRANCE , 1st STORY | Mar 16, 2021 |
| Feb 18, 2021 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | May 24, 2021 |
| Feb 18, 2021 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY | May 24, 2021 |
| Feb 18, 2021 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | May 24, 2021 |
| Feb 18, 2021 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | May 24, 2021 |
| Feb 18, 2021 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY | Feb 24, 2021 |
| Feb 18, 2021 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED | May 24, 2021 |
| Feb 16, 2021 | C | Apt 5A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 13, 2021 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 7:58 AM ET. BBL 3002990004.