Bronx · Block 2646 · Lot 39 · 10455

727 East 156 Street

6 floors · 25 apartments · 16,782 sq ft · built 1906 · class C1 · owner of record: 727-729 East 156th Realty Llc

33open violations
$3,650ECB/OATH penalties owed
13HPD class C (immediately hazardous)
44dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-16 (Accepted). Agency page

Dec 31, 2026
in 44 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 775 days
Next cycle year 2028

Open violations

ECB / OATH (2) · $3,650 owed
IssuedViolationHearingBalance
Sep 9, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 6-STORY BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS INDICATES SIDEWALK SHED PERMIT#X01046285-I1-SH EXPIRED ON 08/04/2026 AND HAS NOT BEEN RE
#39558942J
Nov 20, 2026
PENDING
$1,250
Jun 30, 2026Construction CLASS - 2
AT TIME OF INSPECTION OF 6 STORY MULTIPLY DWELLING PROPERTY WITH PERMITTED SIDEWALK SHED NOT MAINTAINED 1. ROTTING MUDSILLS 2. MISSING REQUIRED EXTENSION 3. NOT TIGHT TO FACADE CAUSING HAZARDOUS CONDITIONS.
#39555981Z
May 13, 2027
$2,400
DOB (7)
IssuedViolationStatus
Jul 25, 2024CONSTRUCTION
EMERGENCY WORK ORDER UNSTABLE FIRE ESCAPE FAILURE TO MAINTAIN & EMERGENCY WORK OBSERVED BROKEN FIRE ESCAPE THREAD AT F3 & F4 AT EXP #3 NORTH ELEVATION. THIS RENDERS FIRE ESCAPE. FIRE EGRESS NEW-CODE COMPLIANT & COMPROMISED EGRESS.OWNER TO REPAIR (UNDER DIRECTION OF LICENSED PROFESSIONAL)IMMEDIATELY
#LL0101NS
DOB VIOLATION - ACTIVE
May 8, 2024CONSTRUCTION
PARTIAL VACATE ORDER.HAZARDOUS CONDITIONS:SPALLING,CRACKED MASONRY BRICK&DETERIORATING MASONRY STUCCO ON FACADE & AT THE PARAPET LEVEL COURTYARDS@ EXP3(N),#2(W) & #4 (EAST)UNABLE TO BE OCCUPIED. REMEDY: VACATE THE ENTIRE COURTYARDS AT EXPOSURES#3(N),#2(WEST)&#4 (EAST) COURTYARDS TO BE USED IN EMERGE
#LL0103AK
DOB VIOLATION - ACTIVE
May 1, 2024CONSTRUCTION
IMMEDIATELY PROVIDE SAFETY MEASURES AND REPAIR DEFECTED EXP1 ON 156 ST REMEDY:IMMEDIATELY ERECT SIDEWALK SHED ON EXP1 156 STREET AND REPAIR D EFECTED FACADE
#LL0107AK
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#22616
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#09270
DOB VIOLATION - ACTIVE
Jan 30, 2007CONSTRUCTION

#0101EP
DOB VIOLATION - ACTIVE
May 17, 1993LOCAL LAW 62/91 - BOILERS

#04424
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jan 1, 2009Boiler LL6291
Active
May 17, 1993Boiler LL6291
Active
HPD (22) · C 13 · B 7 · A 2
IssuedClassViolationCorrect by
Oct 23, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORYNov 27, 2026
Oct 23, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORYNov 6, 2026
Oct 23, 2026CApt 6A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT DOOR IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHNov 6, 2026
Oct 23, 2026CApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT DOOR IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHOct 29, 2026
May 11, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAAug 14, 2026
May 11, 2026CApt 4A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF VINYL FLOOR TILES CREATING TRIP HAZARD IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 17, 2026
May 11, 2026CApt 4A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DEFECTIVE VINYL TILES ON THE FLOOR ,CREATING TRIP HAZARD IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 17, 2026
May 11, 2026CApt 4A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 17, 2026
May 11, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING INFORMATION AT PUBLIC HALL, 1st STORYMay 17, 2026
Oct 27, 2025A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER LOOSE PROPERLY SECURE BY USING APPROPRIATE NUTS AND BOLTS AT FIRE ESCAPE AT NORTHJan 30, 2026
Jul 22, 2025BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL LESS THAN 10 SQ.FT IN THE 1st ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17806949 ISSUED 05-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVEAug 26, 2025
Jul 22, 2025BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 20 SQ FT AT EAST WALL AND CEILING IN THE 5th ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHAug 26, 2025
Apr 7, 2025CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 3, 2025
Apr 7, 2025CApt 6A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 3, 2025
May 20, 2024BApt 5A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL APPROXIMATELY 10 SQ.FT IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 24, 2024
Jan 19, 2024CApt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OF APPROX 10 SQFT AT NORTH WALL, APPROX 10 SQFT AT SOUTH WALL, APPROX 10 SQFT AT WEST WALL, APPROX 10 SQFT AT EAST WALL, AND APPROX 10 SQFT AT CEILING. IN THE BATHROOM LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROFeb 14, 2024
Jan 19, 2024BApt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 5 SQFT AT WEST WALL AND 5SQFT AT NORTH WALL. IN THE FOYER LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 23, 2024
Dec 18, 2023CApt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 13, 2024
Nov 27, 2023BApt 6A · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL PAPER BOXES, CLOTHES, AND HOUSEHOLD ITEMS IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 1, 2024
Oct 31, 2023C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMNov 6, 2023
Oct 25, 2023CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS YARDNov 20, 2023
Sep 14, 2023BApt 1D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 15992283 ISSUED 15-MAY-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).Oct 19, 2023

Issued in the last 120 days

DateSourceWhatNow
Oct 23, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORYOpen
Oct 23, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORYOpen
Oct 23, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT DOOR IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHOpen
Oct 23, 2026HPD C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT DOOR IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHOpen
Sep 9, 2026ECBUnknown: AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 6-STORY BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS INDICATES SIDEWALK SHED PERMIT#X01046285-I1-SH EXPIRED ON 08/04/2026 AND HAS NOT BEEN REOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 6:18 AM ET. BBL 2026460039.