| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-11 (Accepted). Agency page | Dec 31, 2026 in 61 days | 1 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 53,880 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 426 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6595). Agency page | Dec 31, 2035 in 3348 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 21, 2026 | Elevators CLASS - 2 1) PROVIDE MISSING BRAILLE TAG AT 1ST FLOOR LANDING. 2) PROVIDE MISSING IN CASE OF FIRE SIGNAGE ON DESIGNATED LANDINGS 1ST AND 5TH FLOOR. 3) PROVIDE MR SIGNAGE ON ELEVATOR MR DOOR. 4) PROVIDE NEW ELEVATOR COMPA #39201435N | Dec 11, 2026 | $625 |
| Sep 17, 2021 | Elevators CLASS - 2 MISALIGNED CAB MIRROR. PROVIDE MISSING IN CASE OF FIREE SIGNS. PROPERLY LABEL BASEMENT HATCH DOOR. INOPERATIVE PHONE. CLEAN PIT. PROVIDE AVAILABILITY OF KEYS TO MACHINE ROOM IN ORDER TO PERFORM FULL INSPECTION #39047706N | Feb 9, 2022 STIPULATION/IN-VIO | $310 |
| Jan 10, 2020 | Boilers CLASS - 2 ILLEGAL SIDEARM OIL HEATER IN PLACE AND PIPES LEAKING-COIL RELIEF VALVE MISSING-HW TEMPERATURE GAUGE DEFECTIVE-COMBUSTION AIR SWITCH DEFECTIVE-REAR FLAME SIGHT GLASS DEFECTIVE; CORRECT VIOLATION + SUBMIT THE CE #39015562R | May 13, 2020 STIPULATION/IN-VIO | $310 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #34701 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 25, 2026 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 30, 2026 |
| Sep 25, 2026 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 30, 2026 |
| Sep 22, 2026 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY CAPS AT NORTH AND SOUTH WALLS AT PUBLIC HALL, 1st STORY | Oct 27, 2026 |
| Sep 10, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT BLDG.ENTRANCE , 1st STORY | Oct 15, 2026 |
| Sep 10, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT AL;L BALCONIES AT BOTH FIRE ESCAPES AT SOUTH | Dec 14, 2026 |
| Sep 10, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES AT BOTH FIRE ESCAPES AT 2ND EAST OUTER YARD FROM NORTH | Dec 14, 2026 |
| Sep 10, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALLPARTS ON ALL STORIES AT BLDG.FRONT FIRE ESCAPES | Dec 14, 2026 |
| Jun 1, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES AND COMPONENTS AT ALL STORIES AT CENTER COURT AT FIRE ESCAPE | Sep 4, 2026 |
| Dec 3, 2025 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORY BALCONIES AT BOTH FIRE ESCAPES AT 2ND EAST OUTER YARD FROM NORTH | Mar 8, 2026 |
| Dec 3, 2025 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL PARTS ON ALL STORIES AT BUILDING FRONT FIRE ESCAPES | Mar 8, 2026 |
| Dec 3, 2025 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORY BALCONIES AT BOTH FIRE ESCAPES AT SOUTH | Mar 8, 2026 |
| Dec 3, 2025 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORY BALCONIES AT 1ST EAST OUTER YARD FROM NORTH | Mar 8, 2026 |
| Sep 17, 2021 | B | Apt 4E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND ALL WALL APPROXIATMATELY 25 SQUARE FEET IN THE BATHROOM LOCATED AT APT 4E, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Nov 21, 2021 |
| Aug 2, 2021 | B | Apt 6H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (15 SQ. FT. ) IN THE BATHROOM LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 6, 2021 |
| Dec 12, 2017 | B | Apt 6J · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROX. 2 SQ FT. AT CEILING AT NORTHWEST CORNER IN THE 4th ROOM FROM EAST LOCATED AT APT 6J, 6th STORY, 5th APARTMENT FROM NORTH AT EAST | Jan 16, 2018 |
| Dec 12, 2017 | B | Apt 6J · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROX. 2 SQ. FT. AT CEILING IN THE FOYER LOCATED AT APT 6J, 6th STORY, 5th APARTMENT FROM NORTH AT EAST | Jan 16, 2018 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 25, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 22, 2026 | HPD B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY CAPS AT NORTH AND SOUTH WALLS AT PUBLIC HALL, 1st STORY | Open |
| Sep 10, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT BLDG.ENTRANCE , 1st STORY | Open |
| Sep 10, 2026 | HPD A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT AL;L BALCONIES AT BOTH FIRE ESCAPES AT SOUTH | Open |
| Sep 10, 2026 | HPD A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES AT BOTH FIRE ESCAPES AT 2ND EAST OUTER YARD FROM NORTH | Open |
| Sep 10, 2026 | HPD A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALLPARTS ON ALL STORIES AT BLDG.FRONT FIRE ESCAPES | Open |
| Aug 21, 2026 | ECB | Elevators: 1) PROVIDE MISSING BRAILLE TAG AT 1ST FLOOR LANDING. 2) PROVIDE MISSING IN CASE OF FIRE SIGNAGE ON DESIGNATED LANDINGS 1ST AND 5TH FLOOR. 3) PROVIDE MR SIGNAGE ON ELEVATOR MR DOOR. 4) PROVIDE NEW ELEVATOR COMPA | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 11:47 AM ET. BBL 3065950001.