4 floors · 14 apartments · 4,120 sq ft · built 1931 · class C1 · owner of record: Curley
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 64 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-24 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 29, 2024 | Boilers CLASS - 2 WEILMCLAIN EGH-115 BOILER=THE STEAM RETURN IS MISSING BOILER ISOLATION VALVE+BLOW DOWN VALVE@GRD LEVEL+REQUIRED OPERATION CHECK OF THE OPERATING PRESSURE CONTROL+SYPHON LOOP+HWH#2 FLUE PIPE DEFECT+CHIMNEY BASE #39128781H | Jan 8, 2025 IN VIOLATION | $625 |
| Jan 16, 2010 | Boilers CLASS - 3 B354.50A.36 50A SECOND LOW WATER CUT-OFF MISSING ON BOILER #32067627Z | Mar 15, 2010 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 1, 2013 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT #06507 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #14030 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 1, 2013 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 21, 2017 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HINGES AT HATCHWAY DOORS TO CELLAR AT REAR YARD | May 26, 2017 |
| Apr 21, 2017 | B | Apt 1LR · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED CONTACT AT ELECTRICAL OUTLET AT EAST WALL IN THE FOYER LOCATED AT APT 1LR, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | May 26, 2017 |
| Feb 16, 2017 | A | Apt 4RT · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 4RT LOWER LEVEL, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | May 22, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF MISSING ELECTRICAL OUTLET COVER AT EAST WALL IN THE 21st ROOM FROM NORTH LOCATED AT APT 4RT, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 4RT, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 4RT, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 21st ROOM FROM NORTH LOCATED AT APT 4RT, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF MISSING ELECTRICAL OUTLET COVER AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 4RT, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4RT, 4th STORY, 4th APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Dec 2, 2016 | B | Apt 4RT · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4RT, 4th STORY, 4th APARTMENT FROM WEST AT NORTH | Jan 6, 2017 |
| Jun 18, 2012 | B | Apt 1LR · § 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING PURPOSES THE ROOM AT CELLAR ( AT LOWER LEVEL OF DUPLEX APARTMENT) IN THE ENTIRE APARTMENT LOCATED AT APT 1LR, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 23, 2012 |
| Oct 4, 2011 | A | Apt 1LR · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 3rd ROOM FROM NORTH, THE 11th ROOM FROM NORTH LOCATED AT APT 1LR, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2012 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 7:45 PM ET. BBL 3011460015.