4 floors · 8 apartments · 7,000 sq ft · built 1920 · class C1 · owner of record: Zev Zafir Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-20 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 3, 2026 | Construction CLASS - 1 FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER. NOTED: FAILURE TO OBEY VACATE ORDER #B03/2026 ISSUED ON 01/02/2026, APT #1L STILL OCCUPIED. REMEDY: COMPLY WITH VACATE ORDER. #35725821N | Jun 24, 2027 | $10,000 |
| Mar 3, 2026 | Construction CLASS - 1 REMOVED OR DEFACED A WRITTEN POSTED VACATE ORDER. NOTED: AT THE TIME OF INSPECTION A WRITTEN POSTED VACATE ORDER HAS BEEN REMOVED FROM THE FRONT ENTRY DOOR, VACATE ORDER #B03/2026 ISSUED ON 01/02/2026 AND IT WA #35725820L | Jun 24, 2027 | $5,000 |
| Jan 2, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO PROVIDE REQUIRED NATURAL LIGHT AND VENTILATION FOR EVERY BEDROOM. NOTED ATOF INSPECTION ROOM AT CENTER OF UNIT 1L ON THE 1ST FLOOR BEING USED A #35725656Z | Jun 24, 2027 | $2,500 |
| Jan 2, 2026 | Construction CLASS - 1 B. C. 907.2.8. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO PROVIDE FIRE ALARM SYSTEM CLASS "J" AS PER B. C. 907.2.8 FOR TRANSIENT USE AT APARTMENT 1L ON THE 1ST FLOOR. REMEDY: DISCONTINUE #35725655R | Jun 24, 2027 | $2,500 |
| Jan 2, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER B. C. 903.2 AND 27-954 FOR TRANSIENT USE AT APARTMENT 1L ON THE 1ST FLOOR. REMEDY: DISCONT #35725654P | Jun 24, 2027 | $2,500 |
| Jan 2, 2026 | Quality of Life CLASS - 2 PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT REDIDENTIALPURPOSES. DEPARTMENT OF BUILDINGS RECORDS INIDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING. ILLEGAL OCCUPANCY NOT #35725653N | Jun 24, 2027 | $2,500 |
| Jan 2, 2026 | Construction CLASS - 2 WORK WITHOUT PERMIT. WORK NOTED AT CENTER OF UNIT 1L HAVING ERECTED FULL HEIGHT POSTITION WALL CREATING A BEDROOM WITHOUT NATURAL LIGHT AND VENTILATION. REMEDY: OBTAIN ALL PERMITS. #35725657K | Jun 24, 2027 | $1,250 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #39040 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Dec 12, 2012 | B | Apt 3L · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, APARTMENT AT EAST | Jan 16, 2013 |
| Dec 12, 2012 | B | Apt 4L · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 4th STORY, APARTMENT AT EAST | Jan 16, 2013 |
| May 4, 2007 | B | Apt 2R · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FLOOR ESCUTCHEON IN THE 3rd BEDROOM 3 FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY | Jun 20, 2007 |
| May 4, 2007 | B | Apt 2R · SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING HASP AND STAPLE, PADLOCKED IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, APARTMENT AT WEST | Jun 20, 2007 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 4:42 PM ET. BBL 3030410013.