2 floors · 19,287 sq ft · built 1940 · class K2 · owner of record: G&Y Main Street Plaza Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 68 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-08-28 (Accepted). Agency page | Dec 31, 2026 in 68 days | 2 of 2 without an accepted 2026 report yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 20, 2026 | Unknown CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY BUILDING UNDERGOING VERTICAL AND HORIZONTAL ENLARGEMENT, INADEQUATE ROOF PROTECTION WAS OBSERVED AT EXP# 2. COPING STONES ON THE ADJACENT PROPERTY WERE NOT PROTECTED AND W #39554366M | Mar 8, 2027 | $10,000 |
| May 20, 2026 | Construction CLASS - 1 2-STORY BUILDING ACTIVE JOB SITE UNDERGOING VERTICAL AND HORIZONTAL ENLARGEMENT, 6 WORKERS WERE OBSERVED PERFORMING STYROFOAM, STUCCO, ELECTRICAL, AND TILE WORK. REVIEW OF DOB RECORDS FOUND GC PERMIT EXPIRED ON #39554370P | Mar 8, 2027 | $2,500 |
| May 20, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY ACTIVE JOB SITE, A STAIRWAY FROM THE ROOF LEVEL TO THE BASEMENT WAS OBSERVED WITHOUT REQUIRED HANDRAILS, CREATING A HAZARD TO WORKERS AND PERSONNEL. STOP USE OF THE STAIRW #39554368X | Mar 8, 2027 | $2,500 |
| May 20, 2026 | Unknown CLASS - 1 BC3314.1AT INSPECTION OF A 2-STORY BUILDING UNDER VERTICAL/HORIZONTAL ENLARGEMENT, PIPE SCAFFOLD AT EXP# 1 AND 4 WAS UNSAFE DUE TO LOOSE PLANKING, MISSING GUARDRAILS, AND UNSECURED COMPONENTS, CREATING HAZARD T #39554371R | Mar 8, 2027 | $5,000 |
| May 20, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A 2-STORY ACTIVE JOB SITE, THE SIDEWALK SHED AT EXP# 1 &4 WAS NOT MAINTAINED. POSTS WERE OBSERVED FLOATING ABOVE GRADE AND NOT BEARING ON THE SIDEWALK, CREATING AN IMMEDIATE DANGER #39554426P | Mar 8, 2027 | $2,400 |
| May 20, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A 2-STORY ACTIVE JOB SITE, A PUMP JACK SCAFFOLD WAS OBSERVED AT EXPOSURE 4 ON THE ADJACENT PROPERTY WITHOUT REQUIRED SAFETY MEASURES OR OVERHEAD PROTECTION, CREATING A HAZARD TO PUB #39554367Y | Mar 8, 2027 | $5,000 |
| May 20, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY ACTIVE JOB SITE, STYROFOAM RESIDUE WAS OBSERVED THROUGHOUT THE STREET, ON PARKED VEHICLES, AND ADJACENT PROPERTIES, CREATING A HAZARD TO PUBLIC SAFETY AND PROPERTY. STOP A #39554369H | Mar 8, 2027 | $10,000 |
| May 20, 2026 | Site Safety CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY ACTIVE JOB SITE, MULTIPLE UNSAFE VIOLATING CONDITIONS WERE OBSERVED. REQUEST WAS MADE FOR SUPERINTENDENT MADISON RAMIREZ ROSA;#- 027410) HOWEVER, HE WAS NOT PRESENT AT THE #39554425N | Mar 8, 2027 | $10,000 |
| May 7, 2025 | Construction CLASS - 1 ECB39535775J ISSUED 01/08/2025 NOTES X BRACE PROTRUDING PASS CURB LINE,NOT RESOLVED,HAZARD INTERFERENCE OF MOBILE VEHICLE IN EVENT PARALLEL PARKING STRIKING DELIVERY TRUCKS LEADS SWS INSTABILITY AND COLLAPSE.BC #39539942X | Jan 8, 2026 DEFAULT | $6,250 |
| Mar 10, 2025 | Construction CLASS - 2 RESPONDENT FAILED TO CORRECT VIOLATING CONDITION AND FILE FOR A CERTIFICATE OF CORRECTION PURSUANT TO AC 28-204.4 FOR VIOLATION NO. 39535759J ISSUED 01/08/2025. AT TIME OF INSPECTION, I OBSERVED INACTIVE CLOSED #39537803R | May 20, 2025 IN VIOLATION | $17 |
| Mar 10, 2025 | Construction CLASS - 2 RESPONDENT FAILED TO CORRECT VIOLATING CONDITION AND FILE FOR A CERTIFICATE OF CORRECTION PURSUANT TO AC 28-204.4 FOR VIOLATION NO. 39535775J ISSUED 01/08/2025. AT TIME OF INSPECTION, I OBSERVED INACTIVE CLOSED #39537804Z | May 20, 2025 IN VIOLATION | $625 |
| Jan 8, 2025 | Site Safety CLASS - 1 @ACTIVE ENLARGEMENT SITE WITH SUPERINTENDENT ON PERMIT I REQUESTED ONSITE PERSONNEL FOR SITE SAFETY PLAN&ORIENTATION, SIDEWALK SHED+FENCE PLAN,RECENT PRE-SHIFT SAFETY MEETING LOG&NONE WERE PROVIDED TO ENSURE SO #39535758H | Mar 18, 2025 IN VIOLATION | $1,050 |
| Jan 8, 2025 | Construction CLASS - 1 @ACTIVE ENLARGEMENT SITE OBSERVED NO DEBRIS CONTAINER ON SITE FOR DEMO'D DEBRIS, EQUIPMENT AND DEBRIS OBSTRUCTING EGRESS PASSAGEWAY TO STREET, AND DEBRIS ALL OVER TOP OF SIDEWALK SHED DECK CREATING HAZARDS ESPE #39535759J | Mar 18, 2025 IN VIOLATION | $2,500 |
| Jan 8, 2025 | Construction CLASS - 1 SIDEWALK SHED. OBSERVE SIDEWALK SHED IN PLACE ON MAIN ST TO 72 DR NOT CONFORM TO PLANS WITH MISSING HORIZONTAL BRACES WHERE X BRACES IN PLACE FOR VERTICAL MEMBERS@GROUND LEVEL, TALL SHED X PIPE BRACE ABOVE GROU #39535775J | Mar 18, 2025 IN VIOLATION | $2,500 |
| Jan 8, 2025 | Unknown CLASS - 2 @ACTIVE ENLARGEMENT SITE OBSERVE INCOMPLETE EXTERIOR WORK (EXTERIOR MASONRY WALL FINISH&PARAPET) APPROX. 20FT ABOVE ADJOIN NEIGHBORING PROPERTY ROOF@EXP#2(72-68)&THE PROTECTION OF ROOF IN PLACE NOT EXTENDED 20' #39535760R | Mar 18, 2025 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 1998 | BOILER #92525-02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 8) | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 6:38 PM ET. BBL 4066230084.