8 floors · 60 apartments · 70,801 sq ft · built 2023 · class D7 · owner of record: Rw 705 Franklin Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 61 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 70,801 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 844 days | Filing window not open yet |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1231). Agency page | Dec 31, 2031 in 1887 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 28, 2025 | Unknown CLASS - 2 VIOLATING CONDITION OBSERVED FIRE EXTINGUISHERS LAST MAINTENCE DATE 12/12/2024 THROUGHOUT BUILDING ON EVERY FLOOR. VIO FOR FAILURE TO MAINTAIN FIRE EXTINGUISHERS.MAINTAIN FIRE EXTINGUISHER #39544206Y | Mar 29, 2027 DEFAULT | $1,562 |
| Jun 23, 2025 | Construction CLASS - 3 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AT THE TIME OF INSPECTION, I OBSERVED NEW FLASHING PAINTED BLACK ON THE LEFT SIDE OF THE BUILDING ON FRANKLIN AVENUE FOR BUIL #39151736Y | Aug 27, 2025 IN VIOLATION | $500 |
| May 21, 2025 | Construction CLASS - 2 OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP#3 NEXT TO/ABOVE ADJ PROPERTY-WITH WORK TO BE COMPLETED (STUCCO/PARAPET WALL COPINGS-WITH NO ROOF PROTECTION IN PLACE AND NO WINDOW PROTECTION-AS PER SSP/CODE ADJ PRO #39540467Y | Aug 6, 2025 IN VIOLATION | $625 |
| Feb 7, 2025 | Unknown CLASS - 1 FAILURE TO ENSURE EACH WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING. AT THE TIME OF INSPECTION OF 8 STORY NB, AS I ENTERED THE CONSTRUCTION SITE I OBSERVED A MR. EWGENY SCHWARTZ IN THE SITE WITH DRESS SH #39137807L | Apr 16, 2025 IN VIOLATION | $5,000 |
| Feb 7, 2025 | Unknown CLASS - 2 MISCELLANEOUS CHAPTER 33 VIOLATIONS. FLOOR NUMBERING AND FLOOR ELEVATION. AT THE TIME OF INSPECTION FOR 8-STORY NB, I OBSERVED MISSING FLOOR NUMBERING ON MULTIPLE LEVELS INCLUDING THE 8, 1, 5, 4, 3, AND ON LAND #39137808N | Apr 16, 2025 IN VIOLATION | $2,500 |
| Sep 26, 2024 | Unknown CLASS - 1 MISCELLANEOUS VIOLATIONS.3308.6.1.4.1 SUPPORTED SCAFFOLD ALTERNATIVE.AT TIME OF MY INSPECTION OBSERVED:PROPOSED 8 STORIES NEW BUILDING,AT ROOF LEVEL 87FT HEIGHT APPROX.MISSING/INADEQUATE HORIZONTAL NETTING OR A #39532839X | Jan 11, 2027 | $5,030 |
| Sep 26, 2024 | Plumbing CLASS - 1 AT TIME OF INSPECTION CONSTRUCTION WORK IN PROGRESS BUILDING APPROXIMATELY 87 FEET IN HEIGHT. UPON REQUEST FOR HYDROSTATIC TEST NON WAS PROVIDED AND UPON REVIEW OF DEPARTMENT RECORDS NON WAS AVAILABLE. FAILURE #39532855X | Jan 11, 2027 | $2,430 |
| Sep 26, 2024 | Unknown CLASS - 1 3303.8 STANDING PIPE. AT TIME OF MY INSPECTION OBSERVED: PROPOSED 8 STORIES NEW BUILDING, AT ROOF LEVEL 87 FEET HEIGHT APPROX. MISSING/INADEQUATE STANDPIPE IN STATE OF READINESS, CREATING A POTENTIAL FIRE HAZAR #39532840N | Jan 11, 2027 | $5,030 |
| Sep 26, 2024 | Plumbing CLASS - 1 AT TIME OF INSPECTION CONSTRUCTION WORK IN PROGRESS BUILDING APPROXIMATELY 87 FEET IN HEIGHT. I OBSERVED STANDPIPE WAS NOT PAINTED RED AND THERE WAS NO AIR PRESSURIZED ALARM SYSTEM (GAUGE) PROVIDED OR MAINTAIN, #39532854Y | Jan 11, 2027 | $5,030 |
| Aug 6, 2024 | Unknown CLASS - 1 AT THE TIME OF INSPECTION WHILE RESPONDING TO AN COMPLAINT, I OBSERVED 4 WINDOWS UNPROTECTED AT EXPOSURE#3 CORNER LOCATED BETWEEN AN ACTIVE CONSTRUCTION SITE AT 705 FRANKLIN AVENUE CREATING A HAZARDOUS CONDITIO #39531163K | Oct 16, 2024 IN VIOLATION | $5,000 |
| Aug 6, 2024 | Unknown CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED AN ACTIVE, SITE AT SUPERSTRUCTURE PHASE WITHOUT A CONTROL ACCESS ZONE AT EXPOSURE #3 CORNER IN THE COURTYARD, TO GUIDE AND PROTECT WORKERS FROM ANY FALLING DEBRIS OR OBJECT #39531164M | Oct 16, 2024 IN VIOLATION | $2,500 |
| Jul 23, 2024 | Construction CLASS - 2 OBSERVED SEWER CLOGGING RESULTING FROM INADEQUATE WASHOUT PROCEDURES AT EXPOSURES #1 & #4. OBSERVED DRY CONCRETE RESIDUE ALONG CURBS LEADING INTO SEWER AS WELL. THIS CONDITION IS A CLEAR VIOLATION THAT IS NOT I #39530783R | Mar 27, 2025 IN VIOLATION | $2,500 |
| May 1, 2024 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING AT 2ND FLOOR DECKING, I OBSERVED CONCRETE PUMP TRUCK ON STREET WITH CONCRETE TRUCK PUMPING CONCRETE TO THE 2ND FLOOR. UPON REVIEW OF THE SITE SAFETY PLANS #39528184M | May 16, 2025 IN VIOLATION | $625 |
| May 1, 2024 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENT. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTUCTIONSITE. OBSERVED CONCRETE PLACEMENT TAKEN PLACE ON THE FLOOR #2 SLAB AND #35681880L | Feb 3, 2025 DEFAULT | $6,250 |
| May 1, 2024 | Construction CLASS - 1 NO SITE-SPECIFIC FORMWORK DESIGN DRAWINGS PRESENT PER 3301.7. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTUCTION SITES. OBSERVED 8 STORY NEW BUILDING CONCRETE PLACEMENT WORK ON THE FLOOR #2 SLAB AND FLOOR #35681881N | Feb 3, 2025 DEFAULT | $6,250 |
| May 1, 2024 | Unknown CLASS - 1 BC 3315.1.6 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING, I OBSERVED CONCRETE PUMP TRUCK ON STREET WITH CONCRETE TRUCK PUMPING CONCRETE TO THE 2ND FLOOR AND THE SPACE BETWEEN THE CONSTRUCTION FENCE AN #39528187H | Jan 22, 2026 IN VIOLATION | $2,500 |
| May 1, 2024 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING, I OBSERVED CONCRETE PUMP TRUCK ON STREET WITH CONCRETE TRUCK PUMPING CONCRETE TO THE 2ND FLOOR.UPON REVIEW OF THE DOT PERMITS SITE WAS TO MAINTAIN 11 FEET #39528185Y | Jan 22, 2026 IN VIOLATION | $5,000 |
| May 1, 2024 | Unknown CLASS - 1 BC 3307.4- 3307.4.3 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING, I OBSERVED CONCRETE PUMP TRUCK ON STREET WITH CONCRETE TRUCK PUMPING CONCRETE TO THE 2ND FLOOR WITH CONCRETE WASHOUT BOX AND THERE WER #39528186X | Nov 26, 2024 IN VIOLATION | $3,069 |
| Apr 24, 2024 | Unknown CLASS - 2 RESPONDING A COMPLAINT OBSERVED: CRACKS AT THE WALL EXPO# 4 OF 703 FRANKLIN AVENUE NO SHOWING ON PRE-CONSTRUCTION SURVEY PHOTO# 26 TOOK ON 02/08/2023, CREATING AN UNSAFE CONDITION FOR ADJOINING OCCUPIED BUILDIN #39527935J | Aug 11, 2025 IN VIOLATION | $2,500 |
| Apr 23, 2024 | Unknown CLASS - 2 THAT THE CONTRACTOR FAILED TO COMPLY W/ DOT STIPULATION IN REGARDS TO SIDEWALK OCCUPANCY DURING BOOM LIFT OPERATIONS. 5 FOOT PASSAGEWAY NOT PROVIDED AND FLAGGER INADEQUATELY DIRECTING PEDESTRIANS ACROSS ROADWAY #39527907M | Jan 24, 2025 IN VIOLATION | $625 |
| Mar 12, 2024 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BUILDING AT EXCAVATION/FOUNDATION PHASE, I OBSERVED SUPPORT OF EXCAVATION WAS INADEQUATE TO ADJOINING BUILDING AT 651 PARK PLACE WHICH RESULT IN THE WALL AT EXPOSUR #39526378L | Apr 7, 2025 IN VIOLATION | $420 |
| Mar 22, 1993 | Construction Non-Hazardous ALTERED BUILDING OCCUPIED WITHOUT FIRST OBTAINING A CERTIFICATE OF OCCUPANCY UNDER ALT 448-87. REMEDY- OBTAIN A VALID C OF O #34088863X | Jun 28, 1993 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #20787 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Mar 6, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 11, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 14, 2026 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 1:43 PM ET. BBL 3012310001.