Manhattan · Block 1318 · Lot 1 · 10017

711 3 Avenue

19 floors · 544,150 sq ft · built 1956 · class O6 · owner of record: Slg 711 Fee

10open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
64dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 64 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 544,150 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $1,197,360 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 481 days
No Cycle 10 report on record yet
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1318). Agency page

Dec 31, 2028
in 795 days
Next due 2028

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Dec 12, 2024Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:OBSERVED AT EXPOSURE 3 EAST ELEVATION,SPALLING CONCRETE SLABS AND DETERIORATED STEEL RAILINGS AT MULTIPLE LOCATIONS OF THE FIRE TOWER BALCONIE
#35689306N
May 8, 2025
IN VIOLATION
$0
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #904569.REMEDY:FILE ACCEPTABLE REPORT.
#37026233R
Feb 13, 2025
IN VIOLATION
$0
DOB (5)
IssuedViolationStatus
Mar 5, 2025FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00042
DOB VIOLATION - ACTIVE
Dec 12, 2024CONSTRUCTION
EMERGENCY WORK ORDER TO IMMEDLY REPAIR FIRE TOWER BALCONIES @ EXP3, E.ELEV, DUE TO HAZARD CONDITIONS OBSERVED, SUCH AS SPALLING CONCRETE BALCONY SLABS AND DETERIORATED STEEL RAILINGS. REMEDY: IMMEDIATELY REPAIR UNSAFE CONDITIONS UNDER SUPERVISION OF AN LISCENED PROFESSIONAL AND PROVIDE ADEQUATE SAFE
#LL0603SB
DOB VIOLATION - ACTIVE
Nov 1, 2023FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
FAILURE TO CORRECT SWARMP CONDITIONS
#00054
DOB VIOLATION - ACTIVE
Feb 17, 2023HAZARDOUS CONDITION (FACADE)
CYCLE 9B UNSAFE REPORT FILED
#910828
DOB VIOLATION - ACTIVE
Sep 20, 2012ELEVATOR

#9028/439768
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Mar 5, 2025AEUHAZ FTC-AEU-HAZ
Active
Nov 1, 2023Facades FISPFCS
CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS
Active
Feb 17, 2023Facades FISPHAZ
CYCLE 9B UNSAFE REPORT FILED
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 1:22 PM ET. BBL 1013180001.

Look up another building