3 floors · 37,536 sq ft · built 1901 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 37,536 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 432 days | Next cycle year 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-12 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 9, 2026 | Construction CLASS - 2 REISSUE: 35676261X-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE GAS, METER ROOM THERE'S WATER DAMAGE TO THE WALL. REMEDY: COMPLY WITH CODE. #35728632H | Mar 9, 2026 POP/IN-VIO | $0 |
| Feb 20, 2024 | Construction CLASS - 2 REISSUE#35657631K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT CELLAR GAS METER ROOM WITHOUT IN FUTRATED THROUGHOUT FOUNDATION.REM:REPAIR AND OR/REPLACE. #35676261X | May 2, 2024 POP/IN-VIO | $0 |
| Jan 19, 2023 | Construction CLASS - 2 RE-ISSUE #35591686Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED AT CELLAR LEVEL IN GAS METER ROOM,DAMAGES THROUGHOUT ROOM DUE TO WATER PENETRATION.REMEDY:REPAIR AND/OR REPLACE. #35657631K | Apr 12, 2023 POP/IN-VIO | $0 |
| Jul 19, 2022 | Boilers CLASS - 2 CORRODED RETURN LINE, CORRORDED HAND HOLES, MANUAL RESET LOW WATER CUT OFF MISSING, CONTROLS NOT ON STEAM HEADER PIPING. #39066175R | Jul 27, 2022 POP/IN-VIO | $0 |
| Apr 6, 2022 | Construction CLASS - 2 REISSUE#35548384J.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED OBSERVED AT GAS METER ROOM AT BASEMENT LEVEL.THERE ARE DAMAGESTO THE WALL DUE TO WATER PENETRATION.REMEDY:REPAIR AND/OR REPLACE. #35591686Z | Sep 21, 2022 POP/IN-VIO | $0 |
| Mar 26, 2021 | Construction CLASS - 2 REISSUE35495744H FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.NOTE:OBSERVED IN GASMETERRM WALLS HAVE DAMAGE DUE TO WATER PENETRATION.REPAIR &/OR REPLACE. #35548384J | Sep 1, 2021 POP/IN-VIO | $0 |
| May 26, 2020 | Construction CLASS - 2 REISSUE#35423317K FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NOTED: OBSERVED IN GAS METER ROOM WALLS & CEILING HAVE DAMAGE DUE TO WATER PENETRATION. REMEDY: REPAIR &/OR REPLACE. #35495744H | Jul 6, 2020 POP/IN-VIO | $0 |
| May 30, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED AT 3RD FLOOR STAIRCASE B,C,E BASEMENT GAS METER ROOM WITH HAVING WATER PENETRATION DAMAGE TO WALLS & CEILINGS ALSO AT 3RD FLR AUDITORIUM.RM:REPAIR AND #35423317K | Oct 7, 2019 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
None open.