16 floors · 52 apartments · 61,193 sq ft · built 1906 · class RM · owner of record: The Croft Building Condominium
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-22 (Accepted). Agency page | Dec 31, 2026 in 58 days | 1 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 61,193 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 789 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 79). Agency page | Dec 31, 2029 in 1154 days | Next due 2029 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $231,000 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: UNSAFE (2025-12-03) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 27, 2026 | Unknown CLASS - 1 NOTE:AT TIME OF INSPECTION OF A 16-STORY BUILDING, WITH ONGOING HOISTING OPERATIONS FROM THE ROOF LEVEL DOWN TO THE STREET I OBSERVED THAT THERE WERE NO SOLID FENCE OR BARRIERS IN PLACE AS PER 3307.4.7 TO PROTE #39561121J | Dec 31, 2026 PENDING | $5,000 |
| Oct 1, 2025 | Construction CLASS - 1 RESPONDING TO AN INCIDENT WHERE WORKER HAND WAS CUT WITH A GRINDER, INSPECTION REVEALED THE DEWALT GRINDER IN USE WAS NOT USED AS PER MANUFACTURE SPECIFICATION, OBSERVED GRINDER USED FOR MASONRY BRICK CUTTING H #39545525X | Jun 1, 2027 DEFAULT | $6,250 |
| Aug 12, 2025 | Construction CLASS - 2 ATOI, NO DEBRIS PRESENT AT STREET LEVEL. SIDEWALK SHED HAS BEEN INSTALLED WITH VALID PERMIT #M01086829-11-SH WHICH EXPIRES 2/28/26. HOWEVER, FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION FOR VIOLATION #39055710 #39156815P | Jun 11, 2026 IN VIOLATION | $1,250 |
| Aug 11, 2025 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.AT TIME OF ISNPECTION FAILURE TO OBTAIN PERMITS AS PER VIOLATION#35668866Z ISSUED ON 4/17/2023.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER NON COMPLIANT #35721508Z | May 13, 2027 DEFAULT | $12,500 |
| Aug 11, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTIONS WITH THE DEPARTMENT OF BUILDINGS.AT TIME OF INSPECTION NO CERTIFICATE OF CORRECTION OBTAINED FOR VIOLATION#35668864P ISSUED O #35721507R | May 13, 2027 DEFAULT | $6,250 |
| Apr 17, 2024 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:OBSERVED PREVIOUSLY ISSUED VIOLATION"#020822CLL10101RF"ON "O2/08/2022" WITH CONDITIONS" AS OF TODAY 4/17/2024 DOB FACADE UNIT STILL NEVER RECEIVED #35682346X | Jul 25, 2024 IN VIOLATION | $2,500 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#900229.REM:FILE ACCEPTABLE REPORT. #37026320P | May 2, 2024 DEFAULT | $6,250 |
| Oct 17, 2023 | Plumbing CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. EXHAUST DISCHARGE MUST BE NO CLOSER THAN 10'-0" FROM BUILDING OPENINGS PER MC 501.2. EXHAUST DISCHARGE FOR "SAKURA TERIYAKI" IS APPROX 8'-0" FROM OPERABLE #39097338Y | Jan 25, 2024 IN VIOLATION | $0 |
| Oct 17, 2023 | Construction CLASS - 2 FAILURE TO CONDUCT OR FILE A FINAL INSPECTION OF PERMITTED WORK WITH THE DOB. PERMITS ISSUED UNDER JOB #140428614 WITH WORK COMPLETED HOWEVER JOB SIGN OFF WAS NEVER OBTAINED. DIRECTIVE 14 JOB., CONDUCT/FILE FIN #39097333P | Jan 25, 2024 IN VIOLATION | $0 |
| Apr 17, 2023 | Zoning CLASS - 2 ILLEGAL USE IN COMMERCIAL DISTRICT UNLICENSED PHYSICAL TREATMENT ESTABLISHMENT PROHIBITED USE PER ZR12-10 OPERATING IN C5-5 DISTRICT AT CELLAR LEVEL.MASSEUSE OFFERED TO PERFORM FULL BODY MASSAGE AT RATE OF $60/ #35668865R | Feb 13, 2025 IN VIOLATION | $0 |
| Apr 17, 2023 | Construction CLASS - 1 WORK W/O PERMIT.WORK NOTED:AT CELLAR LEVEL ERECTED PARTITION WALLS CREATING 5 RMS.INSTALLED WATER & WASTE PLUMBING LINES FOR ADDITIONAL RESIDENTIAL SINK.REMEDY:OBTAIN PERMIT. #35668866Z | Feb 13, 2025 IN VIOLATION | $0 |
| Apr 17, 2023 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY NO#103721386F ILLEGAL OCCUPANCY NOTED:AT CELLAR LEVEL CONVERTED/OCCUPIED AS "JP SPA" WITH 5 MASSAGE RMS,MASSAGE TABLES,OILS,TOWELS & UNLICENSED MAS #35668864P | Feb 13, 2025 IN VIOLATION | $0 |
| Feb 8, 2022 | Construction CLASS - 1 FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.NOTE:OBSERVED AT EXP.#2(JOHN ST) 16TH FL A MISSING PIECE OF LIMESTONE AT WINDOWS LINTEL THATEARLIER HAD FALLEN OFF & LANDED ON TO THE SIDEWALK BELOW.W/NO SIDEWALK #35640229L | Sep 1, 2022 IN VIOLATION | $2,500 |
| Feb 8, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED FACADE IN DISREPAIR AT EXP #1 WITH 12"X 3" PIECE OF LIMESTONE HAVING FALLEN TO PUBLIC SIDEWALK DIRECTLY IN FRONT OF 25 JOHN STREET WHERE NO SWS PRESENT #39055710X | Aug 4, 2022 IN VIOLATION | $625 |
| Issued | Violation | Status |
|---|---|---|
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00015 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00016 | DOB VIOLATION - ACTIVE |
| Feb 8, 2022 | CONSTRUCTION AS PER CONDITIONS OBSERVED ON EXP 2 SOUTH ELEVATION-JOHN ST. DEFECTIVE STONEWORK, CRACKED AND SPALLING CONDITIONS. REMEDY: IMMED RETAIN A NYS LIC'D PROF TO PERFORM A 100% HANDS ON INSPECTION OF THE BLDG AND PROVIDE INSPECTION REPORT AND REPAIR PLANS TO DOB BY 3/8/22 #LL10101RF | DOB VIOLATION - ACTIVE |
| Jun 23, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #909375 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 23, 2021 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 27, 2026 | ECB | Unknown: NOTE:AT TIME OF INSPECTION OF A 16-STORY BUILDING, WITH ONGOING HOISTING OPERATIONS FROM THE ROOF LEVEL DOWN TO THE STREET I OBSERVED THAT THERE WERE NO SOLID FENCE OR BARRIERS IN PLACE AS PER 3307.4.7 TO PROTE | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)