3 floors · 130,347 sq ft · built 1952 · class W1 · owner of record: Nyc Department Of Parks And Recreation
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 64 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 130,347 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2248). Agency page | Dec 31, 2028 in 795 days | Next due 2028 |
| Annual boiler inspection (6 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-27 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 22, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).NOTED:ILLEGAL INSTALLATION OF HARDWARE KICK STOPS ON FIRE RATED DOORS AND CLASSROOMS ON ROO #35734867N | Aug 20, 2026 POP/IN-VIO | $0 |
| Jul 22, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725163K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED;GENERATOR THAT SUPPLIES EMERGENCY POWER FOR SOUTH WIRING PORTION OF SCHOOL IS NOT WORKING AND HAS NOT BEEN WORKING FOR QUITE #35734865J | Aug 20, 2026 POP/IN-VIO | $0 |
| Jul 22, 2026 | Construction CLASS - 2 REISSUE ON ECB #35725166X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE RATED CLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING, MISSING AND/OR FAULTY HARDWARE ON CLASSROOMS 12, 1 #35734863X | Aug 14, 2026 POP/IN-VIO | $0 |
| Jul 22, 2026 | Construction CLASS - 2 REISSUE ON ECB #35725165Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: EMERGENCY ILLUMINATED DISCHARGE EXIT #35734864H | Aug 14, 2026 POP/IN-VIO | $0 |
| Sep 16, 2025 | Construction CLASS - 2 RE-ISSUE 35684699K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, GENERATOR THAT SUPPLIES EMERGENCY POWER FOR SOUTH WING IS NOT WORKING. REMEDY: REPAIR AND/OR REPLACE. #35725163K | Oct 24, 2025 POP/IN-VIO | $0 |
| Sep 16, 2025 | Construction CLASS - 2 RE-ISSUE 35684697R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDOR PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION, ONE EMERGENCY LIGHT IN HA #35725165Y | Oct 27, 2025 POP/IN-VIO | $0 |
| Sep 16, 2025 | Construction CLASS - 2 RE-ISSUE 35684696P. FAILURE TO MAINTAIN BUILDING IN COMPLIANT MANNER. AT THE TIME OF INSPECTION, STAIR EXIT DOOR "H" ON 3RD FLOOR, LIBRARY EXIT DOORS, CORRIDOR DOOR NEXT TO LIBRARY, STAGE EXIT DOOR "B", ROOM #3 #35725166X | Oct 27, 2025 POP/IN-VIO | $0 |
| Jul 29, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT 3 FLOOR ROOM327, 2FL. 216, 1FL. STAGE RIGHT, 121, CAFETERIA, 30, CORRIDOR BY RM 20, 18 AND GYM BY EXIT 9 DOORS ARE NOT CLOSING PROPERLY. REMEDY: REPAIR #35684696P | Dec 3, 2024 POP/IN-VIO | $0 |
| Jul 29, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT AUDITORIUM, BX #5, 6, AND GYM EMERGENCY LIGHTS ARE NOT LIGHTING CORR #35684697R | Dec 3, 2024 POP/IN-VIO | $0 |
| Jul 29, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1, 27-381. SOUTH WING GENERATOR NOT WORKING FOR EMERGENCY LIHTING, BASEMENT ROOM 3 #35684699K | Dec 3, 2024 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #16846 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #16847 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #15433 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #15434 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 22, 2026 | ECB | Construction: REISSUE ON ECB #35725764M. EXIT DOOR NOT SELF-CLOSING. NOTED: EMERGENCY EXTERIOR EXIT DOOR NOT SELF-CLOSING DUE TO BINDING, MISSING AND/OR FAULTY HARDWARE AT EXTERIOR DOOR EXIT 8 AT SC LEVEL OBSERVED WHEN TESTE | Closed |
| Jul 22, 2026 | ECB | Construction: EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING,DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS.NOTED:EMERGENCY SIGNS AT ELEVATOR CALL STATION MAP MISSING AT ELEVATOR CALL STATION LOBBY G AT BR LEVEL OBS | Closed |
| Jul 22, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).NOTED:ILLEGAL INSTALLATION OF HARDWARE KICK STOPS ON FIRE RATED DOORS AND CLASSROOMS ON ROO | Open |
| Jul 22, 2026 | ECB | Construction: REISSUE ON ECB#35725163K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED;GENERATOR THAT SUPPLIES EMERGENCY POWER FOR SOUTH WIRING PORTION OF SCHOOL IS NOT WORKING AND HAS NOT BEEN WORKING FOR QUITE | Open |
| Jul 22, 2026 | ECB | Construction: REISSUE ON ECB #35725166X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE RATED CLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING, MISSING AND/OR FAULTY HARDWARE ON CLASSROOMS 12, 1 | Open |
| Jul 22, 2026 | ECB | Construction: REISSUE ON ECB #35725165Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: EMERGENCY ILLUMINATED DISCHARGE EXIT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)