6 floors · 40,320 sq ft · built 2024 · class R0 · owner of record: Prospect Place Brooklyn Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 48 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 48 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,320 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 169 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 169 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 7, 2025 | Construction CLASS - 2 OBSERVATION: @EXPOSURE#2 SUPPORT SCAFFOLD UNSAFE, MISSING TOEBOARD WHILE PERFORMING BRICKWORK, NETTING UNSECURED, DEBRI THROUGHOUT SCAFFOLD. HAZARDOUS CONDITION CAN CAUSE INJURY/HARM. PSWO FOR UNSAFE SCAFFOLD. #39545704L | Aug 21, 2026 IN VIOLATION | $625 |
| Oct 7, 2025 | Unknown CLASS - 2 OBSERVATION: @EXPOSURE#2 SUPPORT SCAFFOLD UNSAFE, MISSING TOEBOARD WHILE PERFORMING BRICKWORK, NETTING UNSECURED, 2ND FLOOR STAGE ROOMS W/O PERMITS, SWS CONTRARY TO PLANS MISSING CROSS BRACES. HOUSEKEEPING INAD #39545710H | Aug 21, 2026 IN VIOLATION | $5,000 |
| Jun 14, 2025 | Construction CLASS - 2 OBSERVED YODOKS INSTALLED CONTRARY TO MANUFACTURING SPECIFICATIONS. MIX MATCH COMPONENTS IN USE PREVENTING ALL YODOKS FROM INTERLOCKING TOGETHER, ALSO NOT FILLED WITH WATER AS PER SPECS. WHICH PREVENTS SHIFTING #39541409K | Apr 15, 2027 | $1,250 |
| Jun 14, 2025 | Construction CLASS - 2 NO CONSTRUCTION ACTIVITY TAKING PLACE AT THE TIME OF 6:45AM. OBSERVED A GARBAGE DEBRIS CONTAINER IN THE STREET LEFT OVER NIGHT UNCOVERED. B.C 3303.4.2. CONTAINER WAS FILLED TO THE TOP WITH GARBAGE COMING OUT CA #39541410H | Sep 8, 2026 IN VIOLATION | $1,250 |
| Jun 14, 2025 | Construction CLASS - 1 OBSERVED ABOUT 10 WORKERS ON SITE PERFORMING CONSTRUCTION ACTIVITIES. SHEET ROCKING, FRAMING, PAINTING, DOING HOUSEKEEPING. UPON CHECKING DEPARTMENT RECORDS. THERE WAS NO AFTER HOUR PERMISSION TO PERFORM THESE #39541406P | Sep 8, 2026 IN VIOLATION | $625 |
| Jun 14, 2025 | Unknown CLASS - 2 6 STORY NB WITH A BUILDING FOOTPRINT(SQ. FT.)5655. OBSERVED NO CONSTRUCTION ACTIVITY TAKIN PLACE AT THE TIME OF 6:45AM. WALKED AROUND THE OUTSIDE OF THE BUILDING TO TAKE MY PICTURES. OBSERVED NO COMPETENT WATCH #39541411J | Apr 15, 2027 | $2,500 |
| Apr 14, 2025 | Unknown CLASS - 2 BC 3307.2 OBSERVED WORK AND STORAGE ZONE NOT FULLY ENCLOSED WITH JERSEY BARRIERS AS PER DOT STIPULATION. STOP ALL USED OF WORK AND STORAGE ZONE EXP#1 PROVIDE ADEQUATE BARRIERS TO PROTECTION PEDESTRIAN. #39539066P | Aug 6, 2026 IN VIOLATION | $625 |
| Apr 14, 2025 | Construction CLASS - 1 ACTIVE SITE OBSERVED INADEQUATE GUARDRAIL SYSTEM AT ELEVATOR SHAFT AND AT ALL OPEN PERIMETERS THRU OUT THE SITED. STOP ALL WORK ENTIRE SITE EXCEPT TO PROVIDE FULL GUARDRAIL SYSTEM AT ELEVATOR SHAFT AND ALL OPEN #39539068Z | Aug 6, 2026 IN VIOLATION | $5,000 |
| Apr 14, 2025 | Construction CLASS - 1 MISCELLANEOUS VIOLATIONS. 15 RCNY 20-08-B ATOI OBSERVED ACTIVE 6 STORYBUILDING FIRE HYDRANT IN USED WHEN ASKED TO PROVIDE PERMIT. NO PERMIT WAS PROVIDED. STOP ALL USE OF FIRE HYDRANT. REMEDY: COMPLY WITH RULE. #39539089H | Aug 6, 2025 DEFAULT | $6,250 |
| Oct 30, 2024 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING AT 5 FLOOR DECKING PHASE, I OBSERVED DUMPSTER CONTAINER AND OFFICE TRAILER ON STREET AT EXPOSURE #1 IN FRONT OF 1417 BEDFORD AVENUE 66 ROGERS AVE. UPON REQ #39534001L | Aug 4, 2025 IN VIOLATION | $625 |
| Oct 30, 2024 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING AT 5 FLOOR DECKING PHASE, I OBSERVED CONCRETE RESIDUE DUMP ON GROUND IN JOBSITE AT EXPOSURE #1&2, RESIDUE WAS LEACHING INTO THE GROUND. FAILURE TO PERFORM #39533999J | Aug 4, 2025 IN VIOLATION | $625 |
| Oct 30, 2024 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING AT 5 FLOOR DECKING PHASE, I OBSERVED ROOF PROTECTION WAS INADEQUATE, A/C UNITS WAS LEFT WITHOUT PROTECTION AT EXPOSURE #2. FAILURE TO PROVIDE ADEQUATE ROOF #39534000J | Aug 4, 2025 IN VIOLATION | $625 |
| Oct 30, 2024 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED APPROXIMATELY 26 WORKERS AT JOB SITE, UPON REQUEST FOR 7 WORKERS SITE SAFETY ORIENTATION AND REFRESHER NONE WAS PRESENTED OR AT JOB SITE. FAIL #39533998H | Aug 4, 2025 IN VIOLATION | $1,250 |
| Oct 30, 2024 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING AT 5 FLOOR DECKING PHASE, I OBSERVED AT EXPOSURE #2 AND 3 GUARDRAILS WERE MISSING ON THE 4 FLOOR LEVEL. FAILURE TO PROVIDE ADEQUATE GUARDRAILS CREATES A FA #39534002N | Aug 4, 2025 IN VIOLATION | $625 |
| Oct 30, 2024 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING AT 5 FLOOR DECKING PHASE, I OBSERVED THAT THERE WERE NO OVERHEAD PROTECTION AT EXPOSURE #1 FROM ROLLING GATE TO THE BUILDING. FAILURE TO PROVIDE OVERHEAD P #39534003P | Aug 4, 2025 IN VIOLATION | $625 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 13, 2026, 8:52 PM ET. BBL 3012257501.