Manhattan · Block 1390 · Lot 9 · 10021

7 East 75 Street

6 floors · 20 apartments · 13,580 sq ft · built 1902 · class D3 · owner of record: 7 East 75 Llc

17open violations
$17,500ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-12 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual

Open violations

ECB / OATH (7) · $17,500 owed
IssuedViolationHearingBalance
Jan 14, 2026Elevators CLASS - 2
CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE.PROVIDE TO GAIN ACCESS TO ELEVATOR MACHINE ROOM AND OVERHEAD FOR INSPECTION. PROVIDE A WORKING PHONE NUMBER CONTACT INFORMATION FOR SUPERINDENDANT-MANAGEMENT CO.
#39173913N
Mar 26, 2026
DEFAULT
$3,125
Dec 4, 2025Elevators CLASS - 2
2//X/10 OUT SIDE COMM INOPERATIVE REPAIR, 55/H/12 DRUM COUNTERWEIGHTS ROPE WORN RESHACKLE.
#39169350R
Feb 12, 2026
DEFAULT
$3,125
Oct 7, 2020Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35406436Z ISSUED ON 05/14/19 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF O
#35521489X
Dec 24, 2020
DEFAULT
$3,125
Feb 1, 2020Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35406436Z ISSUED ON 05-14-19 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR
#35516735X
Aug 6, 2020
IN VIOLATION
$3,125
Dec 27, 2019Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35406436Z ISSUED ON 05-14-19 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. NO C OF C ON FILE. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C
#35515051K
Jul 23, 2020
IN VIOLATION
$1,250
Oct 1, 2019Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35406436Z ISSUED ON 05-14-19 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C OF C.
#35429854N
Jul 13, 2020
IN VIOLATION
$1,250
May 14, 2019Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS. CO #104824308F INDICATES A 20 UNITS BUILDING WITH CELLAR AS BOILER, STORAGE (1) SUPERS APT AND CELLAR LEVEL OF APT
#35406436Z
Oct 3, 2019
IN VIOLATION
$2,500
DOB (2)
IssuedViolationStatus
Oct 13, 2026CONSTRUCTION
FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD CRACK IN BALCONY, CRACK IS CONTINUOUS FROM FENCE OF STONE ALL THE WAY THROUGHOUT BOTTOM OF STONE BALCONY. OWNER TO RETAIN NYSPE TO EVAL ENTIRE BLDG, PEPARE/FILE REPAIR DWGS, REPAIR BLDG UNDER PERMIT, START WORK BY 12/13/2026
#PI10801TC
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#03665
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
HPD (4) · C 2 · B 2 · A 0
IssuedClassViolationCorrect by
Oct 9, 2025CApt 5CD · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 5CD, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 9, 2025
Aug 13, 2024CApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT WINDOW LOWER SASH IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 19, 2024
Jul 26, 2024BApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT SOUTH WALL IN THE 1st ROOM FROM EAST AT CENTER LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 30, 2024
Apr 16, 2024BApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTERBALANCE AT UPPER AND LOWER SASHES OF SOUTH 1 WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMay 21, 2024

Issued in the last 120 days

DateSourceWhatNow
Oct 13, 2026DOBCONSTRUCTION: FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD CRACK IN BALCONY, CRACK IS CONTINUOUS FROM FENCE OF STONE ALL THE WAY THROUGHOUT BOTTOM OF STONE BALCONY. OWNER TO RETAIN NYSPE TO EVAL ENTIRE BLDG, PEPARE/FILE REPAIR DWGS, REPAIR BLDG UNDER PERMIT, START WORK BY 12/13/2026Open
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 3:15 PM ET. BBL 1013900009.

Look up another building