5 floors · 22 apartments · 18,276 sq ft · built 2025 · class D3 · owner of record: 2954 Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 5, 2026 | Unknown CLASS - 2 DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEAL SSM / SSC/ CS MICHAEL SPINELLA USING HIS LICENSE ON DESIGNATED PERMITS B01086106, B00805221 AND INCLUDING B00996246 NOT IN COMPLIANCE WITH C #39557586H | Dec 14, 2026 | $2,500 |
| Aug 5, 2026 | Unknown CLASS - 1 BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 3 BALCONY AND INTERIOR PLANKS LOOSE NOT TIED DOWN. SCAFFOLD NOT ANCHORED TO STRUCTURE MISSING CROSS-BRASS AND MUDSILL NO GUARDRAIL SY #39557545L | Oct 14, 2026 DEFAULT | $5,030 |
| Aug 5, 2026 | Unknown CLASS - 1 BC 3301.2 INADEQUATE SAFETY MEASURES AT TIME OF INSPECTION OBSERVED WORKER ON UNSAFE SUPPORTED SCAFFOLD AT BALCONIES AND AT INTERIOR WORKER NOT TIES OFF AND NO FALL PROTECTION NO GUARDRAILS. STOP ALL EXTERIOR W #39557544J | Oct 14, 2026 DEFAULT | $5,030 |
| Feb 25, 2026 | Construction CLASS - 2 GC-625238 AT 5:15AM OBSERVED 5 STORY BUILDING WITH SWS THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHTING IN DARK C #39550868Y | May 6, 2026 DEFAULT | $10,000 |
| Nov 20, 2025 | Construction CLASS - 2 OBSERVED ACTIVE JOBSITE W/ CONSTRUCTION FENCE ERECTED AT EXPOSURE #1 MISSING 1-1/2 m SCH. 40 PIPE KICKER CLAMPED TO 3m SCH. 40 PIPE CONTRARY TO THE APPRO VED PLANS. CONDITION COULD LEAD TO DISPLACEMENT OF F #39547188N | Jan 28, 2026 ADMIT/IN-VIO | $0 |
| Nov 20, 2025 | Unknown CLASS - 2 OBSERVD JOBSITE W/DEBRIS CHUTE INSTALLED @ EXPO#3 BALCONIES MISSING TIEBACKS AND ANGLED W/ ADDITIONAL SUPPRTS @1ST FLR CONTRARY TO APPROVED DWGS. CHUTE ACCESS BEYOND PROTECTION. REQUEST FOR WORKERS PROTECTION M #39547186J | Jan 28, 2026 ADMIT/IN-VIO | $0 |
| Nov 20, 2025 | Unknown CLASS - 2 OBSERVED ACTIVE JOBSITE W/ UNFINISHED FACADE, UNFINISHED ROOF, INCOMPLETE PARAPETS ALL LESS THAN 20FT AWAY FROM UNPROTECTED ADJOINING PROPERTY WINDOWS AT EXPOSURE #2. VISIBLE CONCRETE SPLASH MARKS ON SEVERAL WI #39547187L | Jan 28, 2026 ADMIT/IN-VIO | $0 |
| Mar 28, 2025 | Construction CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. CORRUGATED GALVANIZED CONSTRUCTION FENCE APPROX. 15 LINEAR FT AND SUPPORTING METAL POST LOOSE AND LEANING OUTWARD., COMPLY WITH CODE #39143167N | Jun 4, 2025 DEFAULT | $5,000 |
| Dec 22, 2021 | Construction CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. OBSERVED A 10 FT HIGH METAL FENCE IS LOOSE/ OPEN AT REAR, VIEWING PANEL OPEN AND FENCE GATE LEANING AT FRONT OF LOT., COMPLY WITH CODE #39053302H | Feb 5, 2024 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 8, 2026 | CONSTRUCTION BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDERPERMIT #B00996246-S1 ON 10/5/2026. DUE TO CONSTRUCTION SUPERINTENDENTWITHDRAWAL. UNABLE TO DETERMINE PERCENTAGE OF COMPLETED WORK. #26-02361 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 13, 2009 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALL SOUTH BATHROOM 1ST STY APT 1 | Sep 17, 2009 |
| Aug 13, 2009 | A | SECTION 27-2005 ADMIN. CODE: REFIT ENTRANCE TO NORTH BATHROOM 1ST STY APT 1. | Nov 16, 2009 |
| Aug 13, 2009 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE KITCHEN AND CENTER ROOM 1ST STY APT 1 | Sep 17, 2009 |
| Aug 13, 2009 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD SOFFITS AT ROOF ALL STYS OF BLDG. | Sep 17, 2009 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 8, 2026 | DOB | CONSTRUCTION: BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDERPERMIT #B00996246-S1 ON 10/5/2026. DUE TO CONSTRUCTION SUPERINTENDENTWITHDRAWAL. UNABLE TO DETERMINE PERCENTAGE OF COMPLETED WORK. | Open |
| Aug 5, 2026 | ECB | Unknown: DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEAL SSM / SSC/ CS MICHAEL SPINELLA USING HIS LICENSE ON DESIGNATED PERMITS B01086106, B00805221 AND INCLUDING B00996246 NOT IN COMPLIANCE WITH C | Closed |
| Aug 5, 2026 | ECB | Unknown: BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 3 BALCONY AND INTERIOR PLANKS LOOSE NOT TIED DOWN. SCAFFOLD NOT ANCHORED TO STRUCTURE MISSING CROSS-BRASS AND MUDSILL NO GUARDRAIL SY | Open |
| Aug 5, 2026 | ECB | Unknown: BC 3301.2 INADEQUATE SAFETY MEASURES AT TIME OF INSPECTION OBSERVED WORKER ON UNSAFE SUPPORTED SCAFFOLD AT BALCONIES AND AT INTERIOR WORKER NOT TIES OFF AND NO FALL PROTECTION NO GUARDRAILS. STOP ALL EXTERIOR W | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:13 AM ET. BBL 3086650503.