Brooklyn · Block 8665 · Lot 503 · 11235

7 Brighton 5 Place

5 floors · 22 apartments · 18,276 sq ft · built 2025 · class D3 · owner of record: 2954 Owner Llc

13open violations
$27,560ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029

Open violations

ECB / OATH (9) · $27,560 owed
IssuedViolationHearingBalance
Aug 5, 2026Unknown CLASS - 2
DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEAL SSM / SSC/ CS MICHAEL SPINELLA USING HIS LICENSE ON DESIGNATED PERMITS B01086106, B00805221 AND INCLUDING B00996246 NOT IN COMPLIANCE WITH C
#39557586H
Dec 14, 2026
$2,500
Aug 5, 2026Unknown CLASS - 1
BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 3 BALCONY AND INTERIOR PLANKS LOOSE NOT TIED DOWN. SCAFFOLD NOT ANCHORED TO STRUCTURE MISSING CROSS-BRASS AND MUDSILL NO GUARDRAIL SY
#39557545L
Oct 14, 2026
DEFAULT
$5,030
Aug 5, 2026Unknown CLASS - 1
BC 3301.2 INADEQUATE SAFETY MEASURES AT TIME OF INSPECTION OBSERVED WORKER ON UNSAFE SUPPORTED SCAFFOLD AT BALCONIES AND AT INTERIOR WORKER NOT TIES OFF AND NO FALL PROTECTION NO GUARDRAILS. STOP ALL EXTERIOR W
#39557544J
Oct 14, 2026
DEFAULT
$5,030
Feb 25, 2026Construction CLASS - 2
GC-625238 AT 5:15AM OBSERVED 5 STORY BUILDING WITH SWS THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHTING IN DARK C
#39550868Y
May 6, 2026
DEFAULT
$10,000
Nov 20, 2025Construction CLASS - 2
OBSERVED ACTIVE JOBSITE W/ CONSTRUCTION FENCE ERECTED AT EXPOSURE #1 MISSING 1-1/2 m SCH. 40 PIPE KICKER CLAMPED TO 3m SCH. 40 PIPE CONTRARY TO THE APPRO VED PLANS. CONDITION COULD LEAD TO DISPLACEMENT OF F
#39547188N
Jan 28, 2026
ADMIT/IN-VIO
$0
Nov 20, 2025Unknown CLASS - 2
OBSERVD JOBSITE W/DEBRIS CHUTE INSTALLED @ EXPO#3 BALCONIES MISSING TIEBACKS AND ANGLED W/ ADDITIONAL SUPPRTS @1ST FLR CONTRARY TO APPROVED DWGS. CHUTE ACCESS BEYOND PROTECTION. REQUEST FOR WORKERS PROTECTION M
#39547186J
Jan 28, 2026
ADMIT/IN-VIO
$0
Nov 20, 2025Unknown CLASS - 2
OBSERVED ACTIVE JOBSITE W/ UNFINISHED FACADE, UNFINISHED ROOF, INCOMPLETE PARAPETS ALL LESS THAN 20FT AWAY FROM UNPROTECTED ADJOINING PROPERTY WINDOWS AT EXPOSURE #2. VISIBLE CONCRETE SPLASH MARKS ON SEVERAL WI
#39547187L
Jan 28, 2026
ADMIT/IN-VIO
$0
Mar 28, 2025Construction CLASS - 2
JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. CORRUGATED GALVANIZED CONSTRUCTION FENCE APPROX. 15 LINEAR FT AND SUPPORTING METAL POST LOOSE AND LEANING OUTWARD., COMPLY WITH CODE
#39143167N
Jun 4, 2025
DEFAULT
$5,000
Dec 22, 2021Construction CLASS - 2
JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. OBSERVED A 10 FT HIGH METAL FENCE IS LOOSE/ OPEN AT REAR, VIEWING PANEL OPEN AND FENCE GATE LEANING AT FRONT OF LOT., COMPLY WITH CODE
#39053302H
Feb 5, 2024
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Oct 8, 2026CONSTRUCTION
BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDERPERMIT #B00996246-S1 ON 10/5/2026. DUE TO CONSTRUCTION SUPERINTENDENTWITHDRAWAL. UNABLE TO DETERMINE PERCENTAGE OF COMPLETED WORK.
#26-02361
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (4) · C 0 · B 3 · A 1
IssuedClassViolationCorrect by
Aug 13, 2009BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALL SOUTH BATHROOM 1ST STY APT 1Sep 17, 2009
Aug 13, 2009ASECTION 27-2005 ADMIN. CODE: REFIT ENTRANCE TO NORTH BATHROOM 1ST STY APT 1.Nov 16, 2009
Aug 13, 2009BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE KITCHEN AND CENTER ROOM 1ST STY APT 1Sep 17, 2009
Aug 13, 2009BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD SOFFITS AT ROOF ALL STYS OF BLDG.Sep 17, 2009

Issued in the last 120 days

DateSourceWhatNow
Oct 8, 2026DOBCONSTRUCTION: BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDERPERMIT #B00996246-S1 ON 10/5/2026. DUE TO CONSTRUCTION SUPERINTENDENTWITHDRAWAL. UNABLE TO DETERMINE PERCENTAGE OF COMPLETED WORK.Open
Aug 5, 2026ECBUnknown: DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEAL SSM / SSC/ CS MICHAEL SPINELLA USING HIS LICENSE ON DESIGNATED PERMITS B01086106, B00805221 AND INCLUDING B00996246 NOT IN COMPLIANCE WITH CClosed
Aug 5, 2026ECBUnknown: BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 3 BALCONY AND INTERIOR PLANKS LOOSE NOT TIED DOWN. SCAFFOLD NOT ANCHORED TO STRUCTURE MISSING CROSS-BRASS AND MUDSILL NO GUARDRAIL SYOpen
Aug 5, 2026ECBUnknown: BC 3301.2 INADEQUATE SAFETY MEASURES AT TIME OF INSPECTION OBSERVED WORKER ON UNSAFE SUPPORTED SCAFFOLD AT BALCONIES AND AT INTERIOR WORKER NOT TIES OFF AND NO FALL PROTECTION NO GUARDRAILS. STOP ALL EXTERIOR WOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:13 AM ET. BBL 3086650503.